CoChat

Intuitive Control of a Powered Prosthetic Leg During Ambulation: A Randomized Clinical Trial

Hargrove, Levi J., Young, Aaron J., Simon, Ann M., Fey, Nicholas P., Lipschutz, Robert D., Finucane, Suzanne B., Halsne, Elizabeth G., Ingraham, Kimberly A., Kuiken, Todd A. · 2015 · JAMA
Cited by 153

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

IMPORTANCE: Some patients with lower leg amputations may be candidates for motorized prosthetic limbs. Optimal control of such devices requires accurate classification of the patient's ambulation mode (eg, on level ground or ascending stairs) and natural transitions between different ambulation modes. OBJECTIVE: To determine the effect of including electromyographic (EMG) data and historical information from prior gait strides in a real-time control system for a powered prosthetic leg capable of level-ground walking, stair ascent and descent, ramp ascent and descent, and natural transitions between these ambulation modes. DESIGN, SETTING, AND PARTICIPANTS: Blinded, randomized crossover clinical trial conducted between August 2012 and November 2013 in a research laboratory at the Rehabilitation Institute of Chicago. Participants were 7 patients with unilateral above-knee (n = 6) or knee-disarticulation (n = 1) amputations. All patients were capable of ambulation within their home and community using a passive prosthesis (ie, one that does not provide external power). INTERVENTIONS: Electrodes were placed over 9 residual limb muscles and EMG signals were recorded as patients ambulated and completed 20 circuit trials involving level-ground walking, ramp ascent and descent, and stair ascent and descent. Data were acquired simultaneously from 13 mechanical sensors embedded on the prosthesis. Two real-time pattern recognition algorithms, using either (1) mechanical sensor data alone or (2) mechanical sensor data in combination with EMG data and historical information from earlier in the gait cycle, were evaluated. The order in which patients used each configuration was randomized (1:1 blocked randomization) and double-blinded so patients and experimenters did not know which control configuration was being used. MAIN OUTCOMES AND MEASURES: The main outcome of the study was classification error for each real-time control system. Classification error is defined as the percentage of steps incorrectly predicted by the control system. RESULTS: Including EMG signals and historical information in the real-time control system resulted in significantly lower classification error (mean, 7.9% [95% CI, 6.1%-9.7%]) across a mean of 683 steps (range, 640-756 steps) compared with using mechanical sensor data only (mean, 14.1% [95% CI, 9.3%-18.9%]) across a mean of 692 steps (range, 631-775 steps), with a mean difference between groups of 6.2% (95% CI, 2.7%-9.7%] (P = .01). CONCLUSIONS AND RELEVANCE: In this study of 7 patients with lower limb amputations, inclusion of EMG signals and temporal gait information reduced classification error across ambulation modes and during transitions between ambulation modes. These preliminary findings, if confirmed, have the potential to improve the control of powered leg prostheses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.2015.4527

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Hargrove, L. J., Young, A. J., Simon, A. M., Fey, N. P., Lipschutz, R. D., Finucane, S. B., Halsne, E. G., Ingraham, K. A., & Kuiken, T. A.
Venue
JAMA
Published
2015-06-09
Volume
313
Issue
22
Pages
2244
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W1797342007
Cited by
153
References
3
FWCI
6.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.