The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Prognostic Accuracy of Sepsis-3 Criteria for In-Hospital Mortality Among Patients With Suspected Infection Presenting to the Emergency Department
Open accessAbstract
Importance: An international task force recently redefined the concept of sepsis. This task force recommended the use of the quick Sequential Organ Failure Assessment (qSOFA) score instead of systemic inflammatory response syndrome (SIRS) criteria to identify patients at high risk of mortality. However, these new criteria have not been prospectively validated in some settings, and their added value in the emergency department remains unknown. Objective: To prospectively validate qSOFA as a mortality predictor and compare the performances of the new sepsis criteria to the previous ones. Design, Settings, and Participants: International prospective cohort study, conducted in France, Spain, Belgium, and Switzerland between May and June 2016. In the 30 participating emergency departments, for a 4-week period, consecutive patients who visited the emergency departments with suspected infection were included. All variables from previous and new definitions of sepsis were collected. Patients were followed up until hospital discharge or death. Exposures: Measurement of qSOFA, SOFA, and SIRS. Main Outcomes and Measures: In-hospital mortality. Results: Of 1088 patients screened, 879 were included in the analysis. Median age was 67 years (interquartile range, 47-81 years), 414 (47%) were women, and 379 (43%) had respiratory tract infection. Overall in-hospital mortality was 8%: 3% for patients with a qSOFA score lower than 2 vs 24% for those with qSOFA score of 2 or higher (absolute difference, 21%; 95% CI, 15%-26%). The qSOFA performed better than both SIRS and severe sepsis in predicting in-hospital mortality, with an area under the receiver operating curve (AUROC) of 0.80 (95% CI, 0.74-0.85) vs 0.65 (95% CI, 0.59-0.70) for both SIRS and severe sepsis (P < .001; incremental AUROC, 0.15; 95% CI, 0.09-0.22). The hazard ratio of qSOFA score for death was 6.2 (95% CI, 3.8-10.3) vs 3.5 (95% CI, 2.2-5.5) for severe sepsis. Conclusions and Relevance: Among patients presenting to the emergency department with suspected infection, the use of qSOFA resulted in greater prognostic accuracy for in-hospital mortality than did either SIRS or severe sepsis. These findings provide support for the Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3) criteria in the emergency department setting. Trial Registration: clinicaltrials.gov Identifier: NCT02738164.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The third international consensus definitions for sepsis and septic shock (Sepsis-3).
Singer, M., Deutschman, C. S., Seymour, C. W., Shankar-Hari, M., Annane, D., Bauer, M., Bellomo, R., Bernard, G. R., Chiche, J.-D., Coopersmith, C. M., et al. (2016) · JAMA · doi:10.1001/jama.2016.0287 · Cited by 28,250
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Severe Sepsis and Septic Shock
Angus, D. C., & van der Poll, T. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208623 · Cited by 3,961
Seymour, C. W., Liu, V. X., Iwashyna, T. J., Brunkhorst, F. M., Rea, T. D., Scherag, A., Rubenfeld, G., Kahn, J. M., Shankar-Hari, M., Singer, M., et al. (2016) · JAMA · doi:10.1001/jama.2016.0288 · Cited by 3,939
STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · BMJ · doi:10.1136/bmj.h5527 · Cited by 3,660
A randomized trial of protocol-based care for early septic shock.
The ProCESS Investigators (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1401602 · Cited by 2,414
The natural history of the systemic inflammatory response syndrome (SIRS). A prospective study
Rangel-Frausto, M. S. (1995) · JAMA · doi:10.1001/jama.273.2.117 · Cited by 2,104
Goal-Directed Resuscitation for Patients with Early Septic Shock
The ARISE Investigators and the ANZICS Clinical Trials Group (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1404380 · Cited by 2,028
Trial of early, goal-directed resuscitation for septic shock.
Mouncey, P. R., Osborn, T. M., Power, G. S., Harrison, D. A., Sadique, M. Z., Grieve, R. D., Jahan, R., Harvey, S. E., Bell, D., Bion, J. F., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1500896 · Cited by 1,604
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Cited by
Mahévas, M., Tran, V.-T., Roumier, M., Chabrol, A., Paule, R., Guillaud, C., Fois, E., Lepeule, R., Szwebel, T.-A., Lescure, F.-X., et al. (2020) · BMJ · doi:10.1136/bmj.m1844 · Cited by 566
Serafim, R., Gomes, J. A., Salluh, J., & Póvoa, P. (2018) · Chest · doi:10.1016/j.chest.2017.12.015 · Cited by 274
SIRS, qSOFA and new sepsis definition
Marik, P. E., & Taeb, A. M. (2017) · Journal of Thoracic Disease · doi:10.21037/jtd.2017.03.125 · Cited by 284
Fernando, S. M., Tran, A., Taljaard, M., Cheng, W., Rochwerg, B., Seely, A. J. E., & Perry, J. J. (2018) · Annals of Internal Medicine · doi:10.7326/m17-2820 · Cited by 281
Delahanty, R. J., Alvarez, J., Flynn, L. M., Sherwin, R. L., & Jones, S. S. (2019) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2018.11.036 · Cited by 206
Metadata
- Authors
- Freund, Y., Lemachatti, N., Krastinova, E., Van Laer, M., Claessens, Y.-E., Avondo, A., Occelli, C., Feral-Pierssens, A.-L., Truchot, J., Ortega, M., Carneiro, B., Pernet, J., Claret, P.-G., Dami, F., Bloom, B., Riou, B., Beaune, S., & for the French Society of Emergency Medicine Collaborators Group
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2017-01-17
- Volume
- 317
- Issue
- 3
- Pages
- 301
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2581766282
- Cited by
- 708
- References
- 22
- FWCI
- 66.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prognostic Accuracy of Sepsis-3 Criteria for In-Hospital Mortality Among Patients With Suspected Infection Presenting to the Emergency Department. https://app.cochat.ai/papers/10.1001/jama.2016.20329
- The paper
- Freund, Y., Lemachatti, N., Krastinova, E., Van Laer, M., Claessens, Y.-E., Avondo, A., Occelli, C., Feral-Pierssens, A.-L., Truchot, J., Ortega, M., Carneiro, B., Pernet, J., Claret, P.-G., Dami, F., Bloom, B., Riou, B., Beaune, S., & for the French Society of Emergency Medicine Collaborators Group. (2017). Prognostic Accuracy of Sepsis-3 Criteria for In-Hospital Mortality Among Patients With Suspected Infection Presenting to the Emergency Department. JAMA. https://doi.org/10.1001/jama.2016.20329
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.