The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Ventilator Weaning and Discontinuation Practices for Critically Ill Patients
Open accessAbstract
Importance: Although most critically ill patients receive invasive mechanical ventilation (IMV), few studies have characterized how IMV is discontinued in practice. Objective: To describe practice variation in IMV discontinuation internationally, associations between initial discontinuation events and outcomes, and factors associated with the use of select discontinuation strategies and failed initial spontaneous breathing trials (SBTs). Design, Setting, and Participants: Prospective, multinational, observational study of critically ill adults who received IMV for at least 24 hours from 142 intensive care units (ICUs) in 19 countries within 6 regions (27 in Canada, 23 in India, 22 in the UK, 26 in Europe, 21 in Australia/New Zealand, and 23 in the US). Exposures: Receiving IMV. Main Outcomes and Measures: Primary analyses characterized types of initial IMV discontinuation events (extubation, SBT, or tracheostomy) and associations with clinical outcomes (including duration of ventilation, ICU and hospital mortality, and ICU and hospital length of stay). Secondary analyses examined the associations between SBT outcome and SBT timing and clinical outcomes. Results: Among 1868 patients (median [interquartile range] age, 61.8 [48.9-73.1] years; 1173 [62.8%] men) 424 (22.7%) underwent direct extubation, 930 (49.8%) had an initial SBT (761 [81.8%] successful), 150 (8.0%) underwent direct tracheostomy, and 364 (19.5%) died before a weaning attempt. Across regions, there was variation in the use of written directives to guide care, daily screening, SBT techniques, ventilator modes, and the roles played by clinicians involved in weaning. Compared with initial direct extubation, patients who had an initial SBT had higher ICU mortality (20 [4.7%] vs 96 [10.3%]; absolute difference, 5.6% [95% CI, 2.6%-8.6%]), longer duration of ventilation (median of 2.9 vs 4.1 days; absolute difference, 1.2 days [95% CI, 0.7-1.6]), and longer ICU stay (median of 6.7 vs 8.1 days; absolute difference, 1.4 days [95% CI, 0.8-2.4]). Patients whose initial SBT failed (vs passed) had higher ICU mortality (29 [17.2%] vs 67 [8.8%]; absolute difference, 8.4% [95% CI, 2.0%-14.7%]), longer duration of ventilation (median of 6.1 vs 3.5 days; absolute difference, 2.6 days [95% CI, 1.6-3.6]), and longer ICU stay (median of 10.6 vs 7.7 days; absolute difference, 2.8 days [95% CI, 1.1-5.2]). Compared with patients who underwent early initial SBTs, patients who underwent late initial SBTs (>2.3 days after intubation) had longer duration of ventilation (median of 2.1 vs 6.1 days; absolute difference, 4.0 days [95% CI, 3.7-4.5]), longer ICU stay (median of 5.9 vs 10.8 days; absolute difference, 4.9 days [95% CI, 4.0-6.3]), and longer hospital stay (median of 14.3 vs 22.8 days; absolute difference, 8.5 days [95% CI, 6.0-11.0]). Conclusions and Relevance: In this observational study of invasive mechanical ventilation discontinuation in 142 ICUs in Canada, India, the UK, Europe, Australia/New Zealand, and the US from 2013 to 2016, weaning practices varied internationally. Trial Registration: ClinicalTrials.gov Identifier: NCT03955874.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526
Calibration: the Achilles heel of predictive analytics
On behalf of Topic Group ‘Evaluating diagnostic tests and prediction models’ of the STRATOS initiative, Van Calster, B., McLernon, D. J., van Smeden, M., Wynants, L., & Steyerberg, E. W. (2019) · BMC Medicine · doi:10.1186/s12916-019-1466-7 · Cited by 2,650
Flexible Imputation of Missing Data, Second Edition
van Buuren, S. (2018) · doi:10.1201/9780429492259 · Cited by 2,273
Flexible Imputation of Missing Data
van Buuren, S. (2012) · doi:10.1201/b11826 · Cited by 2,022
Prospective evaluation of the Sedation-Agitation Scale for adult critically ill patients
Riker, R. R., Picard, J. T., & Fraser, G. L. (1999) · Critical Care Medicine · doi:10.1097/00003246-199907000-00022 · Cited by 961
Selection bias and information bias in clinical research
Tripepi, G., Jager, K. J., Dekker, F. W., & Zoccali, C. (2010) · Nephron Clinical Practice · doi:10.1159/000312871 · Cited by 425
ICU Occupancy and Mechanical Ventilator Use in the United States*
Wunsch, H., Wagner, J., Herlim, M., Chong, D. H., Kramer, A. A., & Halpern, S. D. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318298a139 · Cited by 287
Cited by
Pham, T., Heunks, L., Bellani, G., Madotto, F., Aragao, I., Beduneau, G., Goligher, E. C., Grasselli, G., Laake, J. H., Mancebo, J., et al. (2023) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(22)00449-0 · Cited by 282
Metadata
- Authors
- Burns, K. E. A., Rizvi, L., Cook, D. J., Lebovic, G., Dodek, P., Villar, J., Slutsky, A. S., Jones, A., Kapadia, F. N., Gattas, D. J., Epstein, S. K., Pelosi, P., Kefala, K., Meade, M. O., & Canadian Critical Care Trials Group
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2021-03-23
- Volume
- 325
- Issue
- 12
- Pages
- 1173
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W3137427221
- Cited by
- 196
- References
- 7
- FWCI
- 19.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventilator Weaning and Discontinuation Practices for Critically Ill Patients. https://app.cochat.ai/papers/10.1001/jama.2021.2384
- The paper
- Burns, K. E. A., Rizvi, L., Cook, D. J., Lebovic, G., Dodek, P., Villar, J., Slutsky, A. S., Jones, A., Kapadia, F. N., Gattas, D. J., Epstein, S. K., Pelosi, P., Kefala, K., Meade, M. O., & Canadian Critical Care Trials Group. (2021). Ventilator Weaning and Discontinuation Practices for Critically Ill Patients. JAMA. https://doi.org/10.1001/jama.2021.2384
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.