Exercise Echocardiography or Exercise SPECT Imaging?: A Meta-analysis of Diagnostic Test Performance
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
CONTEXT: Cardiac imaging has advanced rapidly, providing clinicians with several choices for evaluating patients with suspected coronary artery disease, but few studies compare modalities directly. OBJECTIVES: To review the contemporary literature and to compare the diagnostic performance of exercise echocardiography (ECHO) and exercise single-photon emission computed tomography (SPECT) imaging in the diagnosis of coronary artery disease. DATA SOURCES: Studies published between January 1990 and October 1997 identified from MEDLINE search; bibliographies of reviews and original articles; and suggestions from experts in each area. STUDY SELECTION: Articles were included if they discussed exercise ECHO and/or exercise SPECT imaging with thallous chloride TI 201 (thallium) or technetium Tc 99m sestamibi for detection and/or evaluation of coronary artery disease, if data on coronary angiography were presented as the reference test, and if the absolute numbers of true-positive, false-negative, true-negative, and false-positive observations were available or derivable from the data presented. Studies performed exclusively in patients after myocardial infarction, after percutaneous transluminal coronary angioplasty, after coronary artery bypass grafting, or with recent unstable coronary syndromes were excluded. DATA EXTRACTION: Clinical variables, technical factors, and test performance were independently extracted by 2 reviewers on a standardized spreadsheet. Discrepancies were resolved by consensus. RESULTS: Forty-four articles met inclusion criteria. In pooled data weighted by the sample size of each study, exercise ECHO had a sensitivity of 85% (95% confidence interval [CI], 83%-87%) with a specificity of 77% (95% CI, 74%-80%). Exercise SPECT yielded a similar sensitivity of 87% (95% CI, 86%-88%) but a lower specificity of 64% (95% CI, 60%-68%). In a summary receiver operating characteristic model comparing exercise ECHO performance to exercise SPECT, exercise ECHO was associated with significantly better discriminatory power (parameter estimate, 1.18; 95% CI, 0.71-1.65), when adjusted for age, publication year, and a setting including known coronary artery disease for SPECT studies. In models comparing the discriminatory abilities of exercise ECHO and exercise SPECT vs exercise testing without imaging, both ECHO and SPECT performed significantly better than exercise testing. The incremental improvement in performance was greater for ECHO (3.43; 95% CI, 2.74-4.11) than for SPECT (1.49; 95% CI, 0.91-2.08). CONCLUSIONS: Exercise ECHO and exercise SPECT have similar sensitivities for the detection of coronary artery disease, but exercise ECHO has better specificity and, therefore, higher overall discriminatory capabilities as used in contemporary practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Assessment of diagnostic tests when disease verification is subject to selection bias
Begg, C. B., & Greenes, R. A. (1983) · Biometrics · doi:10.2307/2530820 · Cited by 708
Hunink, M. G. M. (1997) · JAMA · doi:10.1001/jama.277.7.535 · Cited by 679
Self-citationBerman, D. S., Kiat, H., Friedman, J. D., Wang, F. P., Van Train, K., Matzer, L., Maddahi, J., & Germano, G. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90557-h · Cited by 528
Estimating Diagnostic Accuracy from Multiple Conflicting Reports: A New Meta-analytic Method
Littenberg, B., & Moses, L. E. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300408 · Cited by 434
Taillefer, R., DePuey, E. G., Udelson, J. E., Beller, G. A., Latour, Y., & Reeves, F. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00435-4 · Cited by 425
Accuracy and limitations of exercise echocardiography in a routine clinical setting
Marwick, T. H., Nemec, J. J., Pashkow, F. J., Stewart, W. J., & Salcedo, E. E. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90054-q · Cited by 383
Quiñones, M. A., Verani, M. S., Haichin, R. M., Mahmarian, J. J., Suarez, J., & Zoghbi, W. A. (1992) · Circulation · doi:10.1161/01.cir.85.3.1026 · Cited by 316
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
2024 ESC Guidelines for the management of chronic coronary syndromes
Vrints, C., Andreotti, F., Koskinas, K. C., Rossello, X., Adamo, M., Ainslie, J., Banning, A. P., Budaj, A., Buechel, R. R., Chiariello, G. A., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae177 · Cited by 2,774
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Self-citationDiagnostic Performance of Coronary Angiography by 64-Row CT
Miller, J. M., Rochitte, C. E., Dewey, M., Arbab-Zadeh, A., Niinuma, H., Gottlieb, I., Paul, N., Clouse, M. E., Shapiro, E. P., Hoe, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806576 · Cited by 1,815
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Self-citationOutcomes of Anatomical versus Functional Testing for Coronary Artery Disease
Douglas, P. S., Hoffmann, U., Patel, M. R., Mark, D. B., Al-Khalidi, H. R., Cavanaugh, B., Cole, J., Dolor, R. J., Fordyce, C. B., Huang, M., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1415516 · Cited by 1,543
Self-citationCoronary CT Angiography and 5-Year Risk of Myocardial Infarction
The SCOT-HEART Investigators (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1805971 · Cited by 1,390
Greenland, P., Bonow, R. O., Brundage, B. H., Budoff, M. J., Eisenberg, M. J., Grundy, S. M., Lauer, M. S., Post, W. S., Raggi, P., Redberg, R. F., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.001 · Cited by 962
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318277d6a0 · Cited by 845
Self-citationPellikka, P. A., Nagueh, S. F., Elhendy, A. A., Kuehl, C. A., & Sawada, S. G. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.07.003 · Cited by 793
O’Rourke, R. A., Brundage, B. H., Froelicher, V. F., Greenland, P., Grundy, S. M., Hachamovitch, R., Pohost, G. M., Shaw, L. J., Weintraub, W. S., Winters, W. L., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00831-7 · Cited by 791
Self-citationGibbons, R. J., Chatterjee, K., Daley, J., Douglas, J. S., Fihn, S. D., Gardin, J. M., Grunwald, M. A., Levy, D., Lytle, B. W., O’Rourke, R. A., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00150-3 · Cited by 633
Pellikka, P. A., Arruda-Olson, A., Chaudhry, F. A., Chen, M. H., Marshall, J. E., Porter, T. R., & Sawada, S. G. (2020) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.07.001 · Cited by 583
O’Rourke, R. A., Brundage, B. H., Froelicher, V. F., Greenland, P., Grundy, S. M., Hachamovitch, R., Pohost, G. M., Shaw, L. J., Weintraub, W. S., Winters, W. L., et al. (2000) · Circulation · doi:10.1161/01.cir.102.1.126 · Cited by 508
Self-citationMulvagh, S. L., Rakowski, H., Vannan, M. A., Abdelmoneim, S. S., Becher, H., Bierig, S. M., Burns, P. N., Castello, R., Coon, P. D., Hagen, M. E., et al. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.09.009 · Cited by 492
Jaarsma, C., Leiner, T., Bekkers, S. C., Crijns, H. J., Wildberger, J. E., Nagel, E., Nelemans, P. J., & Schalla, S. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.12.040 · Cited by 456
Narula, J., Chandrashekhar, Y., Ahmadi, A., Abbara, S., Berman, D. S., Blankstein, R., Leipsic, J., Newby, D., Nicol, E. D., Nieman, K., et al. (2021) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2020.11.001 · Cited by 398
Qaseem, A., Fihn, S. D., Williams, S., Dallas, P., Owens, D. K., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-10-201211200-00010 · Cited by 393
The Updated NICE Guidelines: Cardiac CT as the First-Line Test for Coronary Artery Disease
Moss, A. J., Williams, M. C., Newby, D. E., & Nicol, E. D. (2017) · Current Cardiovascular Imaging Reports · doi:10.1007/s12410-017-9412-6 · Cited by 314
Contrast Echocardiography: Current and Future Applications
Mulvagh, S. L., DeMaria, A. N., Feinstein, S. B., Burns, P. N., Kaul, S., Miller, J. G., Monaghan, M., Porter, T. R., Shaw, L. J., & Villanueva, F. S. (2000) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2000.105462 · Cited by 310
Sampson, U. K., Dorbala, S., Limaye, A., Kwong, R., & Di Carli, M. F. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.015 · Cited by 277
Cost-Effectiveness of Alternative Test Strategies for the Diagnosis of Coronary Artery Disease
Garber, A. M., & Solomon, N. A. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-9-199905040-00003 · Cited by 274
Screening for Coronary Artery Disease After Mediastinal Irradiation for Hodgkin's Disease
Heidenreich, P. A., Schnittger, I., Strauss, H. W., Vagelos, R. H., Lee, B. K., Mariscal, C. S., Tate, D. J., Horning, S. J., Hoppe, R. T., & Hancock, S. L. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.07.0805 · Cited by 262
Parker, M. W., Iskandar, A., Limone, B., Perugini, A., Kim, H., Jones, C., Calamari, B., Coleman, C. I., & Heller, G. V. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.978270 · Cited by 257
Mieres, J. H., Gulati, M., Bairey Merz, N., Berman, D. S., Gerber, T. C., Hayes, S. N., Kramer, C. M., Min, J. K., Newby, L. K., Nixon, J. V. (., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000061 · Cited by 244
Chest Pain Centers: Diagnosis of Acute Coronary Syndromes
STORROW, A., & GIBLER, W. (2000) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(00)70006-0 · Cited by 234
Pharmacologic stress testing for coronary disease diagnosis: A meta-analysis
Kim, C., Kwok, Y. S., Heagerty, P., & Redberg, R. (2001) · American Heart Journal · doi:10.1067/mhj.2001.119761 · Cited by 220
Navare, S. M., Mather, J. F., Shaw, L. J., Fowler, M. S., & Heller, G. V. (2004) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2004.06.128 · Cited by 216
Heijenbrok-Kal, M. H., Fleischmann, K. E., & Hunink, M. G. M. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.04.061 · Cited by 207
Self-citationEmpirical evidence of the importance of comparative studies of diagnostic test accuracy
Takwoingi, Y., Leeflang, M. M. G., & Deeks, J. J. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-7-201304020-00006 · Cited by 187
“8) Imaging 9 (32) 21 (49) 70 (40) 100 (40) Laboratory 9 (32) 11 (26) 41 (23) 61 (25) RDT or POCT 0 1 (2) 5 (3) 6 (2) Self-administered‡ 2 (7) 1 (2) 2 (1) 5 (2) Combinations of any of the above§ 5 (18) 2 (5) 25 (14) 32 (13)”
Visser, K., & Myriam Hunink, M. G. (2000) · Radiology · doi:10.1148/radiology.216.1.r00jl0367 · Cited by 187
“sis can be found in De Vries et al (4) and Fleischmann et al (47).”
BackgroundHemal, K., Pagidipati, N. J., Coles, A., Dolor, R. J., Mark, D. B., Pellikka, P. A., Hoffmann, U., Litwin, S. E., Daubert, M. A., Shah, S. H., et al. (2016) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2016.02.001 · Cited by 164
Self-citationPrognostic significance of impairment of heart rate response to exercise
Elhendy, A., Mahoney, D. W., Khandheria, B. K., Burger, K., & Pellikka, P. A. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00832-5 · Cited by 158
Douglas, P. S., Hoffmann, U., Lee, K. L., Mark, D. B., Al-Khalidi, H. R., Anstrom, K., Dolor, R. J., Kosinski, A., Krucoff, M. W., Mudrick, D. W., et al. (2014) · American Heart Journal · doi:10.1016/j.ahj.2014.03.003 · Cited by 141
Self-citationPsychological testing and psychological assessment: A review of evidence and issues.
Meyer, G. J., Finn, S. E., Eyde, L. D., Kay, G. G., Moreland, K. L., Dies, R. R., Eisman, E. J., Kubiszyn, T. W., & Reed, G. M. (2001) · American Psychologist · doi:10.1037//0003-066x.56.2.128 · Cited by 1,469
Cardiovascular Disease in Women
Stock, E. O., & Redberg, R. (2012) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2012.07.001 · Cited by 65
“Fleischmann et al 1998 K k t l 1999 -- 61% -- 70% 85% 86% 77% 79% 87% 78% 64% 64%wo e a ., Beattie et al., 2003 Average -- 61% -- 70% 81% 84% 73% 76% 77% 81% 69% 66%JACC 2006;47:4S-20S Dr. Cindy Grines 8 Gender Differences in CAD Significance after Diagnostic Cath for ACS 80 90 D Women Men…”
Metadata
- Authors
- Fleischmann, K. E., Hunink, M. G. M., Kuntz, K. M., & Douglas, P. S.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 1998-09-09
- Volume
- 280
- Issue
- 10
- Pages
- 913
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2158335943
- Cited by
- 490
- References
- 40
- FWCI
- 24.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.