The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Exercise Echocardiography or Exercise SPECT Imaging?: A Meta-analysis of Diagnostic Test Performance
Abstract
CONTEXT: Cardiac imaging has advanced rapidly, providing clinicians with several choices for evaluating patients with suspected coronary artery disease, but few studies compare modalities directly. OBJECTIVES: To review the contemporary literature and to compare the diagnostic performance of exercise echocardiography (ECHO) and exercise single-photon emission computed tomography (SPECT) imaging in the diagnosis of coronary artery disease. DATA SOURCES: Studies published between January 1990 and October 1997 identified from MEDLINE search; bibliographies of reviews and original articles; and suggestions from experts in each area. STUDY SELECTION: Articles were included if they discussed exercise ECHO and/or exercise SPECT imaging with thallous chloride TI 201 (thallium) or technetium Tc 99m sestamibi for detection and/or evaluation of coronary artery disease, if data on coronary angiography were presented as the reference test, and if the absolute numbers of true-positive, false-negative, true-negative, and false-positive observations were available or derivable from the data presented. Studies performed exclusively in patients after myocardial infarction, after percutaneous transluminal coronary angioplasty, after coronary artery bypass grafting, or with recent unstable coronary syndromes were excluded. DATA EXTRACTION: Clinical variables, technical factors, and test performance were independently extracted by 2 reviewers on a standardized spreadsheet. Discrepancies were resolved by consensus. RESULTS: Forty-four articles met inclusion criteria. In pooled data weighted by the sample size of each study, exercise ECHO had a sensitivity of 85% (95% confidence interval [CI], 83%-87%) with a specificity of 77% (95% CI, 74%-80%). Exercise SPECT yielded a similar sensitivity of 87% (95% CI, 86%-88%) but a lower specificity of 64% (95% CI, 60%-68%). In a summary receiver operating characteristic model comparing exercise ECHO performance to exercise SPECT, exercise ECHO was associated with significantly better discriminatory power (parameter estimate, 1.18; 95% CI, 0.71-1.65), when adjusted for age, publication year, and a setting including known coronary artery disease for SPECT studies. In models comparing the discriminatory abilities of exercise ECHO and exercise SPECT vs exercise testing without imaging, both ECHO and SPECT performed significantly better than exercise testing. The incremental improvement in performance was greater for ECHO (3.43; 95% CI, 2.74-4.11) than for SPECT (1.49; 95% CI, 0.91-2.08). CONCLUSIONS: Exercise ECHO and exercise SPECT have similar sensitivities for the detection of coronary artery disease, but exercise ECHO has better specificity and, therefore, higher overall discriminatory capabilities as used in contemporary practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Assessment of diagnostic tests when disease verification is subject to selection bias
Begg, C. B., & Greenes, R. A. (1983) · Biometrics · doi:10.2307/2530820 · Cited by 708
Hunink, M. G. M. (1997) · JAMA · doi:10.1001/jama.277.7.535 · Cited by 679
Self-citationBerman, D. S., Kiat, H., Friedman, J. D., Wang, F. P., Van Train, K., Matzer, L., Maddahi, J., & Germano, G. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90557-h · Cited by 528
Estimating Diagnostic Accuracy from Multiple Conflicting Reports: A New Meta-analytic Method
Littenberg, B., & Moses, L. E. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300408 · Cited by 434
Taillefer, R., DePuey, E. G., Udelson, J. E., Beller, G. A., Latour, Y., & Reeves, F. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00435-4 · Cited by 425
Accuracy and limitations of exercise echocardiography in a routine clinical setting
Marwick, T. H., Nemec, J. J., Pashkow, F. J., Stewart, W. J., & Salcedo, E. E. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90054-q · Cited by 383
Quiñones, M. A., Verani, M. S., Haichin, R. M., Mahmarian, J. J., Suarez, J., & Zoghbi, W. A. (1992) · Circulation · doi:10.1161/01.cir.85.3.1026 · Cited by 316
The Declining Specificity of Exercise Radionuclide Ventriculography
Rozanski, A., Diamond, G. A., Berman, D., Forrester, J. S., Morris, D., & Swan, H. J. C. (1983) · New England Journal of Medicine · doi:10.1056/nejm198309013090902 · Cited by 316
Marwick, T. H., Anderson, T., Williams, M. J., Haluska, B., Melin, J. A., Pashkow, F., & Thomas, J. D. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80004-z · Cited by 274
Crouse, L. J., Harbrecht, J. J., Vacek, J. L., Rosamond, T. L., & Kramer, P. H. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90929-f · Cited by 214
Exercise Thallium-201 Scintigraphy in the Diagnosis and Prognosis of Coronary Artery Disease
Kotler, T. S., & Diamond, G. A. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-9-684 · Cited by 201
The diagnostic accuracy of the exercise electrocardiogram: A meta-analysis of 22 years of research
Detrano, R., Gianrossi, R., & Froelicher, V. (1989) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(89)90025-x · Cited by 199
Sex and Test Verification Bias: Impact on the Diagnostic Value of Exercise Echocardiography
Roger, V. L., Pellikka, P. A., Bell, M. R., Chow, C. W. H., Bailey, K. R., & Seward, J. B. (1997) · Circulation · doi:10.1161/01.cir.95.2.405 · Cited by 194
Train, K. F. V., Garcia, E. V., Maddahi, J., Areeda, J., Cooke, C. D., Kiat, H., Silagan, G., Folks, R., Friedman, J. D., & Matzer, L. (1994) · PubMed · Cited by 188
Dagianti, A., Penco, M., Agati, L., Sciomer, S., Dagianti, A., Rosanio, S., & Fedele, F. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00121-f · Cited by 181
Pozzoli, M., Fioretti, P. M., Salustri, A., Reijs, A. E. M., & Roelandt, J. R. T. C. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90040-r · Cited by 180
Gupta, N. C., Esterbrooks, D. J., Hilleman, D. E., & Mohiuddin, S. M. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90474-2 · Cited by 177
Midgette, A. S., Stukel, T. A., & Littenberg, B. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300313 · Cited by 175
Risk Factors in Coronary Artery Disease
Shah, P. (2006) · CRC Press eBooks · doi:10.3109/9781420014570 · Cited by 144
Detection of Coronary Artery Disease With Upright Bicycle Exercise Echocardiography
Ryan, T. A., Segar, D. S., Sawada, S. G., Berkovitz, K. E., Whang, D. D., Dohan, A. M., Duchak, J. M., White, T. E., Foltz, J. M., O’Donnell, J. A., et al. (1993) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(14)80489-6 · Cited by 133
Factors affecting sensitivity and specificity of a diagnostic test: the exercise thallium scintigram
Detrano, R., Jánosi, A., Lyons, K. P., Marcondes, G., Abbassi, N., & Froelicher, V. F. (1988) · The American Journal of Medicine · doi:10.1016/0002-9343(88)90107-6 · Cited by 120
Identification of multivessel coronary artery disease by exercise echocardiography
Roger, V. L., Pellikka, P. A., Oh, J. K., Bailey, K. R., & Tajik, A. J. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90549-5 · Cited by 108
de Vries, S. O., Hunink, M. G. M., & Polak, J. F. (1996) · Academic Radiology · doi:10.1016/s1076-6332(96)80257-1 · Cited by 107
Self-citationWilliams, M., Marwick, T. H., O'Gorman, D. J., & Foale, R. A. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90898-2 · Cited by 106
Hoffmann, R., Lethen, H., Kleinhans, E., Weiss, M., Flachskampf, F. A., & HANRATH, P. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90351-c · Cited by 106
Comparison of dobutamine and exercise echocardiography for detecting coronary artery disease
Cohen, J. L., Ottenweller, J. E., George, A. K., & Duvvuri, S. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90288-n · Cited by 102
Marangelli, V., Iliceto, S., Piccinni, G., Martino, G., Sorgente, L., & RIZZON, P. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90551-7 · Cited by 95
Marwick, T. H., Torelli, J., Harjai, K. J., Haluska, B. A., Pashkow, F. J., Stewart, W. J., & Thomas, J. D. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)81472-0 · Cited by 91
Gated SPECT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities.
Mannting, F., & Morgan-Mannting, M. G. (1993) · PubMed · Cited by 91
Marwick, T. H., D'hondt, A.-M., Mairesse, G. H., Baudhuin, T., Wijns, W. C., Detry, J. M., & Melin, J. A. (1994) · Heart · doi:10.1136/hrt.72.1.31 · Cited by 77
Galanti, G., Sciagrà, R., Comeglio, M., Taddei, T., Bonechi, F., Giusti, F., Pl, M., & Bisi, G. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90278-p · Cited by 76
Palmas, W. R., Friedman, J. D., Diamond, G. A., Silber, H., Kiat, H., & Berman, D. S. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)00523-s · Cited by 73
Kiat, H., Train, K. F. V., Maddahi, J., Corbett, J. R., Nichols, K., McGhie, A. I., Akers, M. S., Friedman, J. D., Roy, L. T., & Berman, D. S. (1990) · American Heart Journal · doi:10.1016/0002-8703(90)90234-o · Cited by 53
Tawa, C. B., Baker, W. B., Kleiman, N. S., Trakhtenbroit, A. D., Desir, R. M., & Zoghbi, W. A. (1996) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(96)90102-9 · Cited by 52
Bjørnstad, K., Aakhus, S., & Hatle, L. (2008) · Cardiology · doi:10.1159/000176932 · Cited by 32
Exercise Echocardiography in the Diagnosis of Coronary Artery Disease
Luotolahti, M., Saraste, M., & Hartiala, J. (1996) · Annals of Medicine · doi:10.3109/07853899608999078 · Cited by 30
Exercise echocardiography: feasibility and value for detection of coronary artery disease.
Tian, J., Zhang, G., Wang, X., Cui, J., & Xiao, J. (1996) · PubMed · Cited by 14
Cited by
2013 ESC guidelines on the management of stable coronary artery disease
Task Force Members, Montalescot, G., Sechtem, U., Achenbach, S., Andreotti, F., Arden, C., Budaj, A., Bugiardini, R., Crea, F., Cuisset, T., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht296 · Cited by 4,510
2024 ESC Guidelines for the management of chronic coronary syndromes
Vrints, C., Andreotti, F., Koskinas, K. C., Rossello, X., Adamo, M., Ainslie, J., Banning, A. P., Budaj, A., Buechel, R. R., Chiariello, G. A., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae177 · Cited by 2,774
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Self-citationDiagnostic Performance of Coronary Angiography by 64-Row CT
Miller, J. M., Rochitte, C. E., Dewey, M., Arbab-Zadeh, A., Niinuma, H., Gottlieb, I., Paul, N., Clouse, M. E., Shapiro, E. P., Hoe, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806576 · Cited by 1,815
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.013 · Cited by 1,555
Self-citation
Metadata
- Authors
- Fleischmann, K. E., Hunink, M. G. M., Kuntz, K. M., & Douglas, P. S.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 1998-09-09
- Volume
- 280
- Issue
- 10
- Pages
- 913
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2158335943
- Cited by
- 490
- References
- 40
- FWCI
- 24.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.