Preliminary Assessment of Inhaled Nitric Oxide for Acute Vaso-occlusive Crisis in Pediatric Patients With Sickle Cell Disease
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
CONTEXT: Vaso-occlusion is central to the painful crises and acute and chronic organ damage in sickle cell disease. Abnormal nitric oxide-dependent regulation of vascular tone, adhesion, platelet activation, and inflammation contributes to the pathophysiology of vaso-occlusion. Nitric oxide may have promise as a mechanism-of-disease-based therapy for treatment of vaso-occlusion. OBJECTIVE: To explore the efficacy and safety of inhaled nitric oxide (INO) for treatment of vaso-occlusive crisis in pediatric patients. DESIGN: Prospective, double-blind, placebo-controlled, randomized clinical trial with enrollment between September 1999 and October 2001. SETTING: Urban, tertiary care children's hospital in the United States. PARTICIPANTS: Twenty patients aged 10 to 21 years with sickle cell disease and severe acute vaso-occlusive crisis. INTERVENTION: Patients were randomly assigned to receive INO (80 ppm with 21% final concentration of inspired oxygen; n = 10), or placebo (21% inspired oxygen; n = 10) for 4 hours. MAIN OUTCOME MEASURES: Change in pain at 4 hours of inhalation compared with preinhalation pain, measured on a 10-cm visual analog scale (VAS); secondary outcome measures were pain over 6 hours, parenteral narcotic use over 24 hours, duration of hospitalization, blood pressure, oxygen saturation, and methemoglobin concentration. RESULTS: Preinhalation VAS pain scores were similar in the INO and placebo groups (P =.80). The decrease in VAS pain scores at 4 hours was 2.0 cm in the INO group and 1.2 cm in the placebo group (P =.37). Repeated-measures analysis of variance for hourly pain scores showed a 1-cm/h greater reduction in the INO group than the placebo group (P =.02). Morphine use over 6 hours was significantly less in the INO group (mean cumulative use, 0.29 vs 0.44 mg/kg; P =.03) but was not different over 4 hours (0.26 vs 0.32 mg/kg; P =.21) or 24 hours (0.63 vs 0.91 mg/kg; P =.15). Duration of hospitalization was 78 and 100 hours in the INO and placebo groups, respectively (P =.19). No INO toxicity was observed. CONCLUSIONS: Results of this exploratory study suggest that INO may be beneficial for acute vaso-occlusive crisis. These preliminary results warrant further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The L-Arginine-Nitric Oxide Pathway
Epstein, F. H., Moncada, S., & Higgs, A. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312303292706 · Cited by 6,678
Inhaled Nitric Oxide for the Adult Respiratory Distress Syndrome
Rossaint, R., Falke, K. J., Lopez, F., Slama, K., Pison, U., & Zapol, W. M. (1993) · New England Journal of Medicine · doi:10.1056/nejm199302113280605 · Cited by 1,811 · cited 2×
“Systolic blood pressure (6 h), mm Hg Lowest 92 97 Mean (SD) 113 (19) 113 (10) Oxygen saturation (4 h), % Lowest 90 94 Mean (SD) 96.”
BackgroundCell-free hemoglobin limits nitric oxide bioavailability in sickle-cell disease
Reiter, C. D., Wang, X., Tanus-Santos, J. E., Hogg, N., Cannon, R. O., Schechter, A. N., & Gladwin, M. T. (2002) · Nature Medicine · doi:10.1038/nm1202-799 · Cited by 1,330 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
Clinical Significance of Reported Changes in Pain Severity☆☆☆★
Todd, K. H., Funk, K. G., Funk, J. P., & Bonacci, R. (1996) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(96)70238-x · Cited by 1,109 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundInhaled nitric oxide as a cause of selective pulmonary vasodilatation in pulmonary hypertension
PEPKEZABA, J. (1991) · The Lancet · doi:10.1016/0140-6736(91)92033-x · Cited by 1,055
Gallagher, E. J., Liebman, M., & Bijur, P. E. (2001) · Annals of Emergency Medicine · doi:10.1067/mem.2001.118863 · Cited by 1,024
Inhaled Nitric Oxide in Full-Term and Nearly Full-Term Infants with Hypoxic Respiratory Failure
(1997) · New England Journal of Medicine · doi:10.1056/nejm199702273360901 · Cited by 865
Inhaled nitric oxide in persistent pulmonary hypertension of the newborn
ROBERTS, J. (1992) · The Lancet · doi:10.1016/0140-6736(92)92686-a · Cited by 863
Circulating Activated Endothelial Cells in Sickle Cell Anemia
Solovey, A., Lin, Y., Browne, P., Choong, S., Wayner, E., & Hebbel, R. P. (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372203 · Cited by 628 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundReactions between nitric oxide and haemoglobin under physiological conditions
Gow, A. J., & Stamler, J. S. (1998) · Nature · doi:10.1038/34402 · Cited by 574 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundHebbel, R. P., Boogaerts, M. A. B., Eaton, J. W., & Steinberg, M. H. (1980) · New England Journal of Medicine · doi:10.1056/nejm198005013021803 · Cited by 518
Disorders of Hemoglobin: Genetics, Pathophysiology, and Clinical Management
Somervaille, T. (2001) · Journal of the Royal Society of Medicine · doi:10.1177/014107680109401119 · Cited by 432
Hypoxia/reoxygenation causes inflammatory response in transgenic sickle mice but not in normal mice
Kaul, D. K., & Hebbel, R. P. (2000) · Journal of Clinical Investigation · doi:10.1172/jci9225 · Cited by 417
Acute Pain Management: Operative or Medical Procedures and Trauma. Clinical Practice Guideline.
Moran, K. (1993) · Journal of Neuroscience Nursing · doi:10.1097/01376517-199304000-00011 · Cited by 407
Belcher, J. D., Marker, P. H., Weber, J. P., Hebbel, R. P., & Vercellotti, G. M. (2000) · Blood · doi:10.1182/blood.v96.7.2451 · Cited by 367
Nitric oxide donor properties of hydroxyurea in patients with sickle cell disease
Gladwin, M. T., Shelhamer, J. H., Ognibene, F. P., Pease‐Fye, M. E., Nichols, J. S., Link, B., Patel, D. B., Jankowski, M. A., Pannell, L. K., Schechter, A. N., et al. (2002) · British Journal of Haematology · doi:10.1046/j.1365-2141.2002.03274.x · Cited by 234 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundMorris, C. R., Kuypers, F. A., Larkin, S., Vichinsky, E. P., & Styles, L. A. (2000) · Journal of Pediatric Hematology/Oncology · doi:10.1097/00043426-200011000-00009 · Cited by 213 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundBelhassen, L., Pelle, G., Sediame, S., Bachir, D., Carville, C., Bucherer, C., Lacombe, C., Galacteros, F., & Adnot, S. (2001) · Blood · doi:10.1182/blood.v97.6.1584 · Cited by 202
Orringer, E. P., Casella, J. F., Ataga, K. I., Koshy, M., Adams-Graves, P., Luchtman-Jones, L., Wun, T., Watanabe, M., Shafer, F., Kutlar, A., et al. (2001) · JAMA · doi:10.1001/jama.286.17.2099 · Cited by 197
Toward validation of pain measurement tools for children: a pilot study
Tyler, D. C., Tu, A., Douthit, J., & Chapman, R. C. (1993) · Pain · doi:10.1016/0304-3959(93)90163-j · Cited by 180 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundPlatelet activation and platelet-erythrocyte aggregates in patients with sickle cell anemia
Wun, T., Paglieroni, T., Tablin, F., Welborn, J., Nelson, K., & Cheung, A. (1997) · Journal of Laboratory and Clinical Medicine · doi:10.1016/s0022-2143(97)90005-6 · Cited by 158
Head, C. A., Brugnara, C., Martinez-Ruiz, R., Kacmarek, R. M., Bridges, K. R., Kuter, D. J., Bloch, K. D., & Zapol, W. M. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119631 · Cited by 144
Self-citationInhaled Nitric Oxide in Sickle Cell Disease with Acute Chest Syndrome
Atz, A. M., & Wessel, D. L. (1997) · Anesthesiology · doi:10.1097/00000542-199710000-00037 · Cited by 142 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundGladwin, M. T., Schechter, A. N., Shelhamer, J. H., Pannell, L. K., Conway, D. A., Hrinczenko, B. W., Nichols, J. S., Pease-Fye, M. E., Noguchi, C. T., Rodgers, G. P., et al. (1999) · Journal of Clinical Investigation · doi:10.1172/jci7637 · Cited by 131 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundMorris, C. R., Kuypers, F. A., Larkin, S., Sweeters, N., Simon, J., Vichinsky, E. P., & Styles, L. A. (2000) · British Journal of Haematology · doi:10.1111/j.1365-2141.2000.02403.x · Cited by 126
Glover, R. E., Ivy, E. D., Orringer, E. P., Maeda, H., & Mason, R. P. (1999) · Molecular Pharmacology · doi:10.1124/mol.55.6.1006 · Cited by 119 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundThe endothelial biology of sickle cell disease
Hebbel, R. P., & Vercellotti, G. M. (1997) · Journal of Laboratory and Clinical Medicine · doi:10.1016/s0022-2143(97)90176-1 · Cited by 117 · cited 2×
“of sites, median (range) 1 (1-3) 1 (1-4)”
BackgroundSullivan, K., Goodwin, S. R., Evangelist, J., Moore, R. D., & Mehta, P. (1999) · Critical Care Medicine · doi:10.1097/00003246-199911000-00039 · Cited by 115
American Journal of Hematology
Zaja, F. F., FANIN, R., Barcellini, W., Cantoni, S., Carpenedo, M., Caparrotti, G., Carrai, V., Renzo, N. D., Santoro, C., Nicola, M. D., et al. (2006) · American Journal of Hematology · doi:10.1002/(issn)1096-8652 · Cited by 107
Nitric oxide therapy in sickle cell disease
Gladwin, M. T., & Schechter, A. N. (2001) · Seminars in Hematology · doi:10.1016/s0037-1963(01)90027-7 · Cited by 91 · cited 2×
“Systolic blood pressure (6 h), mm Hg Lowest 92 97 Mean (SD) 113 (19) 113 (10) Oxygen saturation (4 h), % Lowest 90 94 Mean (SD) 96.”
BackgroundLopez, B. L., Davis‐Moon, L., Ballas, S. K., & Ma, X.-L. (2000) · American Journal of Hematology · doi:10.1002/(sici)1096-8652(200005)64:1<15::aid-ajh3>3.0.co;2-p · Cited by 54 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundEnrolling patients into clinical trials faster using RealTime Recuiting.
Butte, A. J., Weinstein, D. A., & Kohane, I. S. (2000) · PubMed Central · Cited by 51
Computerized recruiting for clinical trials in real time
Weiner, D. L., Butte, A. J., Hibberd, P. L., & FLEISHER, G. R. (2003) · Annals of Emergency Medicine · doi:10.1067/mem.2003.52 · Cited by 49 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundSelf-citationInhaled Nitric Oxide Improves Survival Rates during Hypoxia in a Sickle Cell (SAD) Mouse Model
Martinez-Ruiz, R., Montero-Huerta, P., Hromi, J., & Head, C. A. (2001) · Anesthesiology · doi:10.1097/00000542-200106000-00028 · Cited by 47 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
BackgroundHrinczenko, B. W., Schechter, A. N., Wojtkowski, T. L., Pannell, L. K., Cashon, R. E., & Alayash, A. I. (2000) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2000.3413 · Cited by 22
Kalweit, G. A., Schipke, J. D., Godehardt, E. A. J., & Gams, E. (2001) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.115158 · Cited by 11 · cited 1×
“Time from onset of pain to morphine receipt, median (range), h 17 (3-114) 14 (1-83)”
Background
Cited by
Rees, D. C., Williams, T. N., & Gladwin, M. T. (2010) · The Lancet · doi:10.1016/s0140-6736(10)61029-x · Cited by 2,504
Better Reporting of Harms in Randomized Trials: An Extension of the CONSORT Statement
Ioannidis, J. P. A., Evans, S. J. W., Gøtzsche, P. C., O'Neill, R. T., Altman, D. G., Schulz, K., Moher, D., & for the CONSORT Group* (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-10-200411160-00009 · Cited by 1,593
Kato, G. J., Gladwin, M. T., & Steinberg, M. H. (2007) · Blood Reviews · doi:10.1016/j.blre.2006.07.001 · Cited by 876
Stuart, M. J., & Nagel, R. L. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17192-4 · Cited by 819
Red blood cells express a functional endothelial nitric oxide synthase
Kleinbongard, P. (2006) · Blood · doi:10.1182/blood-2005-10-3992 · Cited by 568
Metadata
- Authors
- Weiner, D. L., Hibberd, P. L., Betit, P., Cooper, A. B., Botelho, C. A., & Brugnara, C.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2003-03-05
- Volume
- 289
- Issue
- 9
- Pages
- 1136
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W1974649841
- Cited by
- 178
- References
- 36
- FWCI
- 6.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.