Manual Chest Compression vs Use of an Automated Chest Compression Device During Resuscitation Following Out-of-Hospital Cardiac Arrest: A Randomized Trial
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
CONTEXT: High-quality cardiopulmonary resuscitation (CPR) may improve both cardiac and brain resuscitation following cardiac arrest. Compared with manual chest compression, an automated load-distributing band (LDB) chest compression device produces greater blood flow to vital organs and may improve resuscitation outcomes. OBJECTIVE: To compare resuscitation outcomes following out-of-hospital cardiac arrest when an automated LDB-CPR device was added to standard emergency medical services (EMS) care with manual CPR. DESIGN, SETTING, AND PATIENTS: Multicenter, randomized trial of patients experiencing out-of-hospital cardiac arrest in the United States and Canada. The a priori primary population was patients with cardiac arrest that was presumed to be of cardiac origin and that had occurred prior to the arrival of EMS personnel. Initial study enrollment varied by site, ranging from late July to mid November 2004; all sites halted study enrollment on March 31, 2005. INTERVENTION: Standard EMS care for cardiac arrest with an LDB-CPR device (n = 554) or manual CPR (n = 517). MAIN OUTCOME MEASURES: The primary end point was survival to 4 hours after the 911 call. Secondary end points were survival to hospital discharge and neurological status among survivors. RESULTS: Following the first planned interim monitoring conducted by an independent data and safety monitoring board, study enrollment was terminated. No difference existed in the primary end point of survival to 4 hours between the manual CPR group and the LDB-CPR group overall (N = 1071; 29.5% vs 28.5%; P = .74) or among the primary study population (n = 767; 24.7% vs 26.4%, respectively; P = .62). However, among the primary population, survival to hospital discharge was 9.9% in the manual CPR group and 5.8% in the LDB-CPR group (P = .06, adjusted for covariates and clustering). A cerebral performance category of 1 or 2 at hospital discharge was recorded in 7.5% of patients in the manual CPR group and in 3.1% of the LDB-CPR group (P = .006). CONCLUSIONS: Use of an automated LDB-CPR device as implemented in this study was associated with worse neurological outcomes and a trend toward worse survival than manual CPR. Device design or implementation strategies require further evaluation. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00120965.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2001) · RePEc: Research Papers in Economics · Cited by 27,577
Modern Applied Statistics with S
Venables, W. N., & Ripley, B. D. (2002) · Statistics and Computing · doi:10.1007/978-0-387-21706-2 · Cited by 24,305
Regression standard errors in clustered samples
Rogers, W. H. (1993) · Stata technical bulletin · Cited by 2,694
Jacobs, I., Nadkarni, V., the ILCOR Task Force on Cardiac Arrest and Cardiopulmonary Resuscitation Outcomes, PARTICIPANTS, C., Bahr, J., Berg, R. A., Billi, J. E., Bossaert, L., Cassan, P., Coovadia, A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000147236.85306.15 · Cited by 2,560
A Note on Robust Variance Estimation for Cluster‐Correlated Data
Williams, R. L. (2000) · Biometrics · doi:10.1111/j.0006-341x.2000.00645.x · Cited by 2,501
Quality of Cardiopulmonary Resuscitation During Out-of-Hospital Cardiac Arrest
Wik, L. (2005) · JAMA · doi:10.1001/jama.293.3.299 · Cited by 1,538
Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest
Abella, B. S., Alvarado, J. P., & Myklebust, H. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.03.040 · Cited by 941
H 2 S Induces a Suspended Animation-Like State in Mice
Blackstone, E., Morrison, M., & Roth, M. B. (2005) · Science · doi:10.1126/science.1108581 · Cited by 802
Cobb, L. A. (1999) · JAMA · doi:10.1001/jama.281.13.1182 · Cited by 730
Self-citationWik, L., Hansen, T. B., Fylling, F., Steen, T., Vaagenes, P., Auestad, B. H., & Steen, P. A. (2003) · JAMA · doi:10.1001/jama.289.11.1389 · Cited by 646
Cited by
Deakin, C. D., Nolan, J. P., Soar, J., Sunde, K., Koster, R. W., Smith, G. B., & Perkins, G. D. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.017 · Cited by 2,700
Panchal, A. R., Bartos, J. A., Cabañas, J. G., Donnino, M. W., Drennan, I. R., Hirsch, K. G., Kudenchuk, P. J., Kurz, M. C., Lavonas, E. J., Morley, P. T., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000916 · Cited by 2,105
European Resuscitation Council Guidelines for Resuscitation 2015
Soar, J., Nolan, J. P., Böttiger, B. W., Perkins, G. D., Lott, C., Carli, P., Pellis, T., Sandroni, C., Skrifvars, M. B., Smith, G. B., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.016 · Cited by 1,503
Callaway, C. W., Soar, J., Aibiki, M., Böttiger, B. W., Brooks, S. C., Deakin, C. D., Donnino, M. W., Drajer, S., Kloeck, W., Morley, P. T., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000273 · Cited by 1,390
European Resuscitation Council Guidelines for Resuscitation 2010 Section 1. Executive summary
Nolan, J. P., Soar, J., Zideman, D. A., Biarent, D., Bossaert, L. L., Deakin, C., Koster, R. W., Wyllie, J., & Böttiger, B. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.021 · Cited by 1,375
European Resuscitation Council Guidelines for Resuscitation 2015
Perkins, G. D., Handley, A. J., Koster, R. W., Castrén, M., Smyth, M. A., Olasveengen, T., Monsieurs, K. G., Raffay, V., Gräsner, J.-T., Wenzel, V., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.015 · Cited by 1,287
Topjian, A. A., Raymond, T. T., Atkins, D., Chan, M., Duff, J. P., Joyner, B. L., Lasa, J. J., Lavonas, E. J., Levy, A., Mahgoub, M., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000901 · Cited by 1,258
European Resuscitation Council Guidelines 2021: Adult advanced life support
Soar, J., Böttiger, B. W., Carli, P., Couper, K., Deakin, C. D., Djärv, T., Lott, C., Olasveengen, T., Paal, P., Pellis, T., et al. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.02.010 · Cited by 1,225
Meaney, P. A., Bobrow, B. J., Mancini, M. E., Christenson, J., de Caen, A. R., Bhanji, F., Abella, B. S., Kleinman, M. E., Edelson, D. P., Berg, R. A., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829d8654 · Cited by 1,072
Self-citationField, J. M., Hazinski, M. F., Sayre, M. R., Chameides, L., Schexnayder, S. M., Hemphill, R., Samson, R. A., Kattwinkel, J., Berg, R. A., Bhanji, F., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970889 · Cited by 1,050
Self-citationSoar, J., Berg, K. M., Andersen, L. W., Böttiger, B. W., Cacciola, S., Callaway, C. W., Couper, K., Cronberg, T., D’Arrigo, S., Deakin, C. D., et al. (2020) · Resuscitation · doi:10.1016/j.resuscitation.2020.09.012 · Cited by 616
Perkins, G. D., Lall, R., Quinn, T., Deakin, C. D., Cooke, M. W., Horton, J., Lamb, S. E., Slowther, A.-M., Woollard, M., Carson, A., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61886-9 · Cited by 538
Improving In-Hospital Cardiac Arrest Process and Outcomes With Performance Debriefing
Edelson, D. P. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.10.1063 · Cited by 479
Thrombolysis during Resuscitation for Out-of-Hospital Cardiac Arrest
Böttiger, B. W., Arntz, H.-R., Chamberlain, D. A., Bluhmki, E., Belmans, A., Danays, T., Carli, P. A., Adgey, J. A., Bode, C., & Wenzel, V. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070570 · Cited by 403
The use of CPR feedback/prompt devices during training and CPR performance: A systematic review
Yeung, J., Meeks, R., Edelson, D., Gao, F., Soar, J., & Perkins, G. D. (2009) · Resuscitation · doi:10.1016/j.resuscitation.2009.04.012 · Cited by 372
Abella, B. S., Edelson, D. P., Kim, S., Retzer, E., Myklebust, H., Barry, A. M., O’Hearn, N., Hoek, T. L. V., & Becker, L. B. (2007) · Resuscitation · doi:10.1016/j.resuscitation.2006.10.027 · Cited by 367
Wik, L., Olsen, J.-A., Persse, D., Sterz, F., Lozano, M., Brouwer, M. A., Westfall, M., Souders, C. M., Malzer, R., van Grunsven, P. M., et al. (2014) · Resuscitation · doi:10.1016/j.resuscitation.2014.03.005 · Cited by 315
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Olasveengen, T. M., Mancini, M. E., Perkins, G. D., Avis, S., Brooks, S., Castrén, M., Chung, S. P., Considine, J., Couper, K., Escalante, R., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000892 · Cited by 257
Soar, J., Callaway, C. W., Aibiki, M., Böttiger, B. W., Brooks, S. C., Deakin, C. D., Donnino, M. W., Drajer, S., Kloeck, W., Morley, P. T., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.042 · Cited by 253
Gates, S., Lall, R., Quinn, T., Deakin, C. D., Cooke, M. W., Horton, J., Lamb, S. E., Slowther, A.-M., Woollard, M., Carson, A., et al. (2017) · Health Technology Assessment · doi:10.3310/hta21110 · Cited by 62
“At the time that the PARAMEDIC trial was initiated, we were aware of two other planned or ongoing trials of mechanical chest compression devices(70,71) and two that had been published.(32,72) These trials used either the LUCAS device (original version of the battery-powered LUCAS-2) or the AutoPulse (ZOLL Medical Corp…”
Method
Metadata
- Authors
- Hallstrom, A., Rea, T. D., Sayre, M. R., Christenson, J., Anton, A. R., Mosesso, V. N., Van Ottingham, L., Olsufka, M., Pennington, S., White, L. J., Yahn, S., Husar, J., Morris, M. F., & Cobb, L. A.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2006-06-14
- Volume
- 295
- Issue
- 22
- Pages
- 2620-8
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2129291952
- Cited by
- 389
- References
- 24
- FWCI
- 32.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.