The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial
Open accessAbstract
BACKGROUND: Mechanical chest compression devices have the potential to help maintain high-quality cardiopulmonary resuscitation (CPR), but despite their increasing use, little evidence exists for their effectiveness. We aimed to study whether the introduction of LUCAS-2 mechanical CPR into front-line emergency response vehicles would improve survival from out-of-hospital cardiac arrest. METHODS: The pre-hospital randomised assessment of a mechanical compression device in cardiac arrest (PARAMEDIC) trial was a pragmatic, cluster-randomised open-label trial including adults with non-traumatic, out-of-hospital cardiac arrest from four UK Ambulance Services (West Midlands, North East England, Wales, South Central). 91 urban and semi-urban ambulance stations were selected for participation. Clusters were ambulance service vehicles, which were randomly assigned (1:2) to LUCAS-2 or manual CPR. Patients received LUCAS-2 mechanical chest compression or manual chest compressions according to the first trial vehicle to arrive on scene. The primary outcome was survival at 30 days following cardiac arrest and was analysed by intention to treat. Ambulance dispatch staff and those collecting the primary outcome were masked to treatment allocation. Masking of the ambulance staff who delivered the interventions and reported initial response to treatment was not possible. The study is registered with Current Controlled Trials, number ISRCTN08233942. FINDINGS: We enrolled 4471 eligible patients (1652 assigned to the LUCAS-2 group, 2819 assigned to the control group) between April 15, 2010 and June 10, 2013. 985 (60%) patients in the LUCAS-2 group received mechanical chest compression, and 11 (<1%) patients in the control group received LUCAS-2. In the intention-to-treat analysis, 30 day survival was similar in the LUCAS-2 group (104 [6%] of 1652 patients) and in the manual CPR group (193 [7%] of 2819 patients; adjusted odds ratio [OR] 0·86, 95% CI 0·64-1·15). No serious adverse events were noted. Seven clinical adverse events were reported in the LUCAS-2 group (three patients with chest bruising, two with chest lacerations, and two with blood in mouth). 15 device incidents occurred during operational use. No adverse or serious adverse events were reported in the manual group. INTERPRETATION: We noted no evidence of improvement in 30 day survival with LUCAS-2 compared with manual compressions. On the basis of ours and other recent randomised trials, widespread adoption of mechanical CPR devices for routine use does not improve survival. FUNDING: National Institute for Health Research HTA - 07/37/69.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2014 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Blaha, M. J., Dai, S., Ford, E. S., Fox, C. S., Franco, S., et al. (2014) · Circulation · doi:10.1161/01.cir.0000441139.02102.80 · Cited by 5,215
Deakin, C. D., Nolan, J. P., Soar, J., Sunde, K., Koster, R. W., Smith, G. B., & Perkins, G. D. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.017 · Cited by 2,700
Self-citationJacobs, I., Nadkarni, V., the ILCOR Task Force on Cardiac Arrest and Cardiopulmonary Resuscitation Outcomes, PARTICIPANTS, C., Bahr, J., Berg, R. A., Billi, J. E., Bossaert, L., Cassan, P., Coovadia, A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000147236.85306.15 · Cited by 2,560
Koster, R. W., Baubin, M. A., Bossaert, L. L., Caballero, A., Cassan, P., Castrén, M., Granja, C., Handley, A. J., Monsieurs, K. G., Perkins, G. D., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.009 · Cited by 1,556
Self-citationQuality of Cardiopulmonary Resuscitation During Out-of-Hospital Cardiac Arrest
Wik, L. (2005) · JAMA · doi:10.1001/jama.293.3.299 · Cited by 1,538
Jacobs, I., Nadkarni, V., Bahr, J., Berg, R. A., Billi, J. E., Bossaert, L., Cassan, P., Coovadia, A., D’Este, K., Finn, J., et al. (2004) · Resuscitation · doi:10.1016/j.resuscitation.2004.09.008 · Cited by 914
Incidence of EMS-treated out-of-hospital cardiac arrest in Europe
Atwood, C., Eisenberg, M. S., Herlitz, J., & Rea, T. D. (2005) · Resuscitation · doi:10.1016/j.resuscitation.2005.03.021 · Cited by 849
Christenson, J., Andrusiek, D., Everson-Stewart, S., Kudenchuk, P., Hostler, D., Powell, J., Callaway, C. W., Bishop, D., Vaillancourt, C., Davis, D., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.852202 · Cited by 759
Giovino, G. A., Mirza, S. A., Samet, J. M., Gupta, P. C., Jarvis, M. J., Bhala, N., Peto, R., Zatonski, W., Hsia, J., Morton, J., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61085-x · Cited by 740
Nolan, J. P., Hazinski, M. F., Billi, J. E., Boettiger, B. W., Bossaert, L., de Caen, A. R., Deakin, C. D., Drajer, S., Eigel, B., Hickey, R. W., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.002 · Cited by 695
Self-citation
Cited by
Panchal, A. R., Bartos, J. A., Cabañas, J. G., Donnino, M. W., Drennan, I. R., Hirsch, K. G., Kudenchuk, P. J., Kurz, M. C., Lavonas, E. J., Morley, P. T., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000916 · Cited by 2,105
Topjian, A. A., Raymond, T. T., Atkins, D., Chan, M., Duff, J. P., Joyner, B. L., Lasa, J. J., Lavonas, E. J., Levy, A., Mahgoub, M., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000901 · Cited by 1,258
Field, J. M., Hazinski, M. F., Sayre, M. R., Chameides, L., Schexnayder, S. M., Hemphill, R., Samson, R. A., Kattwinkel, J., Berg, R. A., Bhanji, F., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970889 · Cited by 1,050
European Resuscitation Council Guidelines for Resuscitation 2015
Monsieurs, K. G., Nolan, J. P., Bossaert, L. L., Greif, R., Maconochie, I. K., Nikolaou, N. I., Perkins, G. D., Soar, J., Truhlář, A., Wyllie, J., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.038 · Cited by 915
Self-citationEpidemiology and outcomes from out-of-hospital cardiac arrests in England
Hawkes, C., Booth, S., Ji, C., Brace-McDonnell, S. J., Whittington, A., Mapstone, J., Cooke, M. W., Deakin, C. D., Gale, C. P., Fothergill, R., et al. (2017) · Resuscitation · doi:10.1016/j.resuscitation.2016.10.030 · Cited by 327
Self-citation
Metadata
- Authors
- Perkins, G. D., Lall, R., Quinn, T., Deakin, C. D., Cooke, M. W., Horton, J., Lamb, S. E., Slowther, A.-M., Woollard, M., Carson, A., Smyth, M., Whitfield, R., Williams, A., Pocock, H., Black, J. J. M., Wright, J., Han, K., & Gates, S.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 385
- Issue
- 9972
- Pages
- 947-955
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2110488567
- Cited by
- 538
- References
- 32
- FWCI
- 64.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial. https://app.cochat.ai/papers/10.1016/s0140-6736(14)61886-9
- The paper
- Perkins, G. D., Lall, R., Quinn, T., Deakin, C. D., Cooke, M. W., Horton, J., Lamb, S. E., Slowther, A.-M., Woollard, M., Carson, A., Smyth, M., Whitfield, R., Williams, A., Pocock, H., Black, J. J. M., Wright, J., Han, K., & Gates, S. (2015). Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial. The Lancet. https://doi.org/10.1016/s0140-6736(14)61886-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.