Identification of Patients at Low Risk for Recurrent Venous Thromboembolism by Measuring Thrombin Generation

Hron, Gregor, Kollars, Marietta, Binder, Bernd R., Eichinger, Sabine, Kyrle, Paul A.·2006·JAMA

Abstract

CONTEXT: Screening of patients with venous thromboembolism (VTE) for thrombophilic risk factors is common clinical practice. Because of the large number of risk factors, assessing the risk of recurrence in an individual patient is complex. A method covering multicausal thrombophilia is therefore required. OBJECTIVE: To investigate the relationship between recurrence of VTE and a simple global coagulation assay measuring thrombin generation. DESIGN, SETTING, AND PARTICIPANTS: Prospective cohort study of 914 patients with first spontaneous VTE who were followed up for an average of 47 months after discontinuation of vitamin K antagonist therapy. The study was conducted at the Department of Internal Medicine I, Medical University of Vienna, Vienna, Austria, between July 1992 and July 2005. Thrombin generation was measured by a commercially available assay system. Patients with a previous or secondary VTE; antithrombin, protein C, or protein S deficiencies; presence of lupus anticoagulant; cancer; or pregnancy were excluded. MAIN OUTCOME MEASURE: Objectively documented symptomatic recurrent VTE. RESULTS: Venous thromboembolism recurred in 100 patients (11%). Patients without recurrent VTE had lower thrombin generation than patients with recurrence (mean [SD], 349.2 [108.0] nM vs 419.5 [110.5] nM, respectively; P<.001). Compared with patients who had thrombin generation greater than 400 nM, the relative risk (RR) of recurrence was 0.42 (95% confidence interval [CI], 0.26-0.67; P<.001) in patients with values between 400 nM and 300 nM; for patients with lower values, the RR was 0.37 (95% CI, 0.21-0.66; P = .001). After 4 years, the probability of recurrence was 6.5% (95% CI, 4.0%-8.9%) among patients with thrombin generation less than 400 nM compared with 20.0% (95% CI, 14.9%-25.1%) among patients with higher values (P<.001). Patients with thrombin generation less than 400 nM, representing two thirds of patients, had a 60% lower RR of recurrence than those with greater values (RR, 0.40; 95% CI, 0.27-0.60; P<.001). CONCLUSION: Measurement of thrombin generation identifies patients at low risk for recurrent VTE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.296.4.397

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 381

Metadata

Authors
Hron, G., Kollars, M., Binder, B. R., Eichinger, S., & Kyrle, P. A.
Venue
JAMA
Published
2006-07-26
Volume
296
Issue
4
Pages
397
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2071039800
Cited by
381
References
22
FWCI
20.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Identification of Patients at Low Risk for Recurrent Venous Thromboembolism by Measuring Thrombin Generation. https://app.cochat.ai/papers/10.1001/jama.296.4.397
The paper
Hron, G., Kollars, M., Binder, B. R., Eichinger, S., & Kyrle, P. A. (2006). Identification of Patients at Low Risk for Recurrent Venous Thromboembolism by Measuring Thrombin Generation. JAMA. https://doi.org/10.1001/jama.296.4.397

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.