Identification of Patients at Low Risk for Recurrent Venous Thromboembolism by Measuring Thrombin Generation
Abstract
CONTEXT: Screening of patients with venous thromboembolism (VTE) for thrombophilic risk factors is common clinical practice. Because of the large number of risk factors, assessing the risk of recurrence in an individual patient is complex. A method covering multicausal thrombophilia is therefore required. OBJECTIVE: To investigate the relationship between recurrence of VTE and a simple global coagulation assay measuring thrombin generation. DESIGN, SETTING, AND PARTICIPANTS: Prospective cohort study of 914 patients with first spontaneous VTE who were followed up for an average of 47 months after discontinuation of vitamin K antagonist therapy. The study was conducted at the Department of Internal Medicine I, Medical University of Vienna, Vienna, Austria, between July 1992 and July 2005. Thrombin generation was measured by a commercially available assay system. Patients with a previous or secondary VTE; antithrombin, protein C, or protein S deficiencies; presence of lupus anticoagulant; cancer; or pregnancy were excluded. MAIN OUTCOME MEASURE: Objectively documented symptomatic recurrent VTE. RESULTS: Venous thromboembolism recurred in 100 patients (11%). Patients without recurrent VTE had lower thrombin generation than patients with recurrence (mean [SD], 349.2 [108.0] nM vs 419.5 [110.5] nM, respectively; P<.001). Compared with patients who had thrombin generation greater than 400 nM, the relative risk (RR) of recurrence was 0.42 (95% confidence interval [CI], 0.26-0.67; P<.001) in patients with values between 400 nM and 300 nM; for patients with lower values, the RR was 0.37 (95% CI, 0.21-0.66; P = .001). After 4 years, the probability of recurrence was 6.5% (95% CI, 4.0%-8.9%) among patients with thrombin generation less than 400 nM compared with 20.0% (95% CI, 14.9%-25.1%) among patients with higher values (P<.001). Patients with thrombin generation less than 400 nM, representing two thirds of patients, had a 60% lower RR of recurrence than those with greater values (RR, 0.40; 95% CI, 0.27-0.60; P<.001). CONCLUSION: Measurement of thrombin generation identifies patients at low risk for recurrent VTE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
The Statistical Analysis of Failure Time Data.
Aitkin, M., Kalbfleisch, J. D., & Prentice, R. L. (1981) · Biometrics · doi:10.2307/2530581 · Cited by 9,877
The Statistical Analysis of Failure Time Data
Klein, J. P. (1982) · Technometrics · doi:10.1080/00401706.1982.10487769 · Cited by 2,215
The Long-Term Clinical Course of Acute Deep Venous Thrombosis
Prandoni, P., Lensing, A. W. A., Cogo, A., Cuppini, S., Villalta, S., Carta, M., Cattelan, A. M., Polistena, P., Bernardi, E., & Prins, M. H. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-125-1-199607010-00001 · Cited by 2,109
Brandt, J. T., Triplett, D. A., Alving, B. M., & Scharrer, I. (1995) · PubMed · Cited by 1,164
Hemorrhagic Complications of Anticoagulant Treatment
Levine, M. N., Raskob, G., Landefeld, S., & Kearon, C. (2001) · Chest · doi:10.1378/chest.119.1_suppl.108s · Cited by 1,134
High plasma levels of factor VIII and the risk of recurrent venous thromboembolism
Kyrle, P. A., Minar, E., Hirschl, M., Bialonczyk, C., Stain, M., Schneider, B., Weltermann, A., Speiser, W., Lechner, K., & Eichinger, S. (2000) · New England Journal of Medicine · doi:10.1056/nejm200008173430702 · Cited by 763 · cited 1×
“Factor VIII and factor IX were measured by 1-stage clotting assays as recently described.(17,18)”
MethodSelf-citationRisk of Fatal Pulmonary Embolism in Patients With Treated Venous Thromboembolism
Douketis, J. D. (1998) · JAMA · doi:10.1001/jama.279.6.458 · Cited by 617
Kyrle, P. A., & Eichinger, S. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71880-8 · Cited by 616
Self-citation
Cited by
Meschia, J. F., Bushnell, C., Boden-Albala, B., Braun, L. T., Bravata, D. M., Chaturvedi, S., Creager, M. A., Eckel, R. H., Elkind, M. S. V., Fornage, M., et al. (2014) · Stroke · doi:10.1161/str.0000000000000046 · Cited by 2,650
Goldstein, L. B., Bushnell, C. D., Adams, R. J., Appel, L. J., Braun, L. T., Chaturvedi, S., Creager, M. A., Culebras, A., Eckel, R. H., Hart, R. G., et al. (2011) · Stroke · doi:10.1161/str.0b013e3181fcb238 · Cited by 1,306
Epidemiology and Risk Factors for Venous Thrombosis
Cushman, M. (2007) · Seminars in Hematology · doi:10.1053/j.seminhematol.2007.02.004 · Cited by 755
Eichinger, S., Heinze, G., Jandeck, L. M., & Kyrle, P. A. (2010) · Circulation · doi:10.1161/circulationaha.109.925214 · Cited by 510
Self-citationMarlu, R., Hodaj, E., Paris, A., Albaladejo, P., Crackowski, J., & Pernod, G. (2012) · Thrombosis and Haemostasis · doi:10.1160/th12-03-0179 · Cited by 501
Metadata
- Authors
- Hron, G., Kollars, M., Binder, B. R., Eichinger, S., & Kyrle, P. A.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2006-07-26
- Volume
- 296
- Issue
- 4
- Pages
- 397
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2071039800
- Cited by
- 381
- References
- 22
- FWCI
- 20.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identification of Patients at Low Risk for Recurrent Venous Thromboembolism by Measuring Thrombin Generation. https://app.cochat.ai/papers/10.1001/jama.296.4.397
- The paper
- Hron, G., Kollars, M., Binder, B. R., Eichinger, S., & Kyrle, P. A. (2006). Identification of Patients at Low Risk for Recurrent Venous Thromboembolism by Measuring Thrombin Generation. JAMA. https://doi.org/10.1001/jama.296.4.397