Association of Clinical Outcomes With Left Ventricular Assist Device Use by Bridge to Transplant or Destination Therapy Intent: The Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) Randomized Clinical Trial
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Importance: Left ventricular assist devices (LVADs) are well established in the treatment of advanced heart failure, but it is unclear whether outcomes are different based on the intended goal of therapy in patients who are eligible vs ineligible for heart transplant. Objective: To determine whether clinical outcomes in the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) trial differed by preoperative categories of bridge to transplant (BTT) or bridge to transplant candidacy (BTC) vs destination therapy (DT). Design, Setting, and Participants: This study was a prespecified secondary analysis of the MOMENTUM 3 trial, a multicenter randomized clinical trial comparing the magnetically levitated centrifugal-flow HeartMate 3 (HM3) LVAD to the axial-flow HeartMate II (HMII) pump. It was conducted in 69 centers with expertise in managing patients with advanced heart failure in the United States. Patients with advanced heart failure were randomized to an LVAD, irrespective of the intended goal of therapy (BTT/BTC or DT). Main Outcomes and Measures: The primary end point was survival free of disabling stroke or reoperation to remove or replace a malfunctioning device at 2 years. Secondary end points included adverse events, functional status, and quality of life. Results: Of the 1020 patients with implants (515 with HM3 devices [50.5%] and 505 with HMII devices [49.5%]), 396 (38.8%) were in the BTT/BTC group (mean [SD] age, 55 [12] years; 310 men [78.3%]) and 624 (61.2%) in the DT group (mean [SD] age, 63 [12] years; 513 men [82.2%]). Of the patients initially deemed as transplant ineligible, 84 of 624 patients (13.5%) underwent heart transplant within 2 years of LVAD implant. In the primary end point analysis, HM3 use was superior to HMII use in patients in the BTT/BTC group (76.8% vs 67.3% for survival free of disabling stroke and reoperation; hazard ratio, 0.62 [95% CI, 0.40-0.94]; log-rank P = .02) and patients in the DT group (73.2% vs 58.7%; hazard ratio, 0.61 [95% CI, 0.46-0.81]; log-rank P < .001). For patients in both BTT/BTC and DT groups, there were not significantly different reductions in rates of pump thrombosis, stroke, and gastrointestinal bleeding with HM3 use relative to HMII use. Improvements in quality of life and functional capacity for either pump were not significantly different regardless of preimplant strategy. Conclusions and Relevance: In this trial, the superior treatment effect of HM3 over HMII was similar for patients in the BTT/BTC or DT groups. It is possible that use of arbitrary categorizations based on current or future transplant eligibility should be clinically abandoned in favor of a single preimplant strategy: to extend the survival and improve the quality of life of patients with medically refractory heart failure. Trial Registration: ClinicalTrials.gov identifier: NCT02224755.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure
Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa012175 · Cited by 3,977
Advanced heart failure treated with continuous-flow left ventricular assist device
Slaughter, M. S., Rogers, J. G., Milano, C. A., Russell, S. D., Conte, J. V., Feldman, D., Sun, B., Tatooles, A. J., Delgado, R. M., Long, J. W., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0909938 · Cited by 3,063
Self-citationUse of a Continuous-Flow Device in Patients Awaiting Heart Transplantation
Miller, L. W., Pagani, F. D., Russell, S. D., John, R., Boyle, A. J., Aaronson, K. D., Conte, J. V., Naka, Y., Mancini, D., Delgado, R. M., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067758 · Cited by 1,733
Self-citationSeventh INTERMACS annual report: 15,000 patients and counting
Kirklin, J. K., Naftel, D. C., Pagani, F. D., Kormos, R. L., Stevenson, L. W., Blume, E. D., Myers, S. L., Miller, M. A., Baldwin, J. T., & Young, J. B. (2015) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2015.10.003 · Cited by 1,364 · cited 1×
“001), and the European Quality of Life–5 dimensions–5 level visual analog scale (mean [SD] score: BTT/ BTC group: baseline, 47 [24] points; 24 months, 75 [17] points; DT group: baseline, 51 [24] points; 24 months, 77 [19] points; both P < .”
A Fully Magnetically Levitated Left Ventricular Assist Device — Final Report
Mehra, M. R., Uriel, N., Naka, Y., Cleveland, J. C., Yuzefpolskaya, M., Salerno, C. T., Walsh, M. N., Milano, C. A., Patel, C. B., Hutchins, S. W., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1900486 · Cited by 1,312
Self-citationIntrapericardial Left Ventricular Assist Device for Advanced Heart Failure
Rogers, J. G., Pagani, F. D., Tatooles, A. J., Bhat, G., Slaughter, M. S., Birks, E. J., Boyce, S. W., Najjar, S. S., Jeevanandam, V., Anderson, A. S., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1602954 · Cited by 758
A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure
Mehra, M. R., Naka, Y., Uriel, N., Goldstein, D. J., Cleveland, J. C., Colombo, P. C., Walsh, M. N., Milano, C. A., Patel, C. B., Jorde, U. P., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1610426 · Cited by 751
Self-citationAaronson, K. D., Slaughter, M. S., Miller, L. W., McGee, E. C., Cotts, W., Acker, M. A., Jessup, M. L., Gregorič, I. D., Loyalka, P., Frazier, O. H., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.058412 · Cited by 688
Heatley, G. J., Sood, P., Goldstein, D. J., Uriel, N. Y., Cleveland, J. C., Middlebrook, D., & Mehra, M. R. (2016) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2016.01.021 · Cited by 158
Self-citationLeft ventricular assist device therapy improves utilization of donor hearts
Aaronson, K. D., Eppinger, M. J., Dyke, D. B. S., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01751-5 · Cited by 134
Implant Strategies Change Over Time and Impact Outcomes
Teuteberg, J. J., Stewart, G. C., Jessup, M. L., Kormos, R. L., Sun, B., Frazier, O. H., Naftel, D. C., & Stevenson, L. W. (2013) · JACC Heart Failure · doi:10.1016/j.jchf.2013.05.006 · Cited by 92 · cited 3×
“8%) were in the BTT/BTC group (mean [SD] age, 55 [12] years; 310 men [78.”
MethodInfluentialAcker, M. A., Pagani, F. D., Stough, W. G., Mann, D. L., Jessup, M. L., Kormos, R. L., Slaughter, M. S., Baldwin, T., Stevenson, L. W., Aaronson, K. D., et al. (2012) · Circulation Heart Failure · doi:10.1161/hhf.0b013e318279f6b5 · Cited by 14
Cited by
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
2023 ESC guidelines for the management of cardiomyopathies
Arbelo, E., Protonotarios, A., Gimeno, J. R., Arbustini, E., Barriales-Villa, R., Basso, C., Bezzina, C. R., Biagini, E., Blom, N. A., de Boer, R. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad194 · Cited by 2,844
Authors/Task Force Members:, McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., et al. (2022) · European Journal of Heart Failure · doi:10.1002/ejhf.2333 · Cited by 2,171
Peled, Y., Ducharme, A., Kittleson, M., Bansal, N., Stehlik, J., Amdani, S., Saeed, D., Cheng, R., Clarke, B., Dobbels, F., et al. (2024) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2024.05.010 · Cited by 240
Morris, A. A., Khazanie, P., Drazner, M. H., Albert, N. M., Breathett, K., Cooper, L. B., Eisen, H. J., O’Gara, P., Russell, S. D., & on behalf of the American Heart Association Heart Failure and Transplantation Committee of the Council on Clinical Cardiology; Council on Arteriosclerosis, T. A. V. B. C. O. C. R. A. I. A. C. O. H. (2021) · Circulation · doi:10.1161/cir.0000000000001016 · Cited by 201
Metadata
- Authors
- Goldstein, D. J., Naka, Y., Horstmanshof, D., Ravichandran, A. K., Schroder, J., Ransom, J., Itoh, A., Uriel, N., Cleveland, J. C., Raval, N. Y., Cogswell, R., Suarez, E. E., Lowes, B. D., Kim, G., Bonde, P., Sheikh, F. H., Sood, P., Farrar, D. J., & Mehra, M. R.
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2020-04-01
- Volume
- 5
- Issue
- 4
- Pages
- 411
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W3000422964
- Cited by
- 165
- References
- 12
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.