Utility of a Deep-Learning Algorithm to Guide Novices to Acquire Echocardiograms for Limited Diagnostic Use
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Importance: Artificial intelligence (AI) has been applied to analysis of medical imaging in recent years, but AI to guide the acquisition of ultrasonography images is a novel area of investigation. A novel deep-learning (DL) algorithm, trained on more than 5 million examples of the outcome of ultrasonographic probe movement on image quality, can provide real-time prescriptive guidance for novice operators to obtain limited diagnostic transthoracic echocardiographic images. Objective: To test whether novice users could obtain 10-view transthoracic echocardiographic studies of diagnostic quality using this DL-based software. Design, Setting, and Participants: This prospective, multicenter diagnostic study was conducted in 2 academic hospitals. A cohort of 8 nurses who had not previously conducted echocardiograms was recruited and trained with AI. Each nurse scanned 30 patients aged at least 18 years who were scheduled to undergo a clinically indicated echocardiogram at Northwestern Memorial Hospital or Minneapolis Heart Institute between March and May 2019. These scans were compared with those of sonographers using the same echocardiographic hardware but without AI guidance. Interventions: Each patient underwent paired limited echocardiograms: one from a nurse without prior echocardiography experience using the DL algorithm and the other from a sonographer without the DL algorithm. Five level 3-trained echocardiographers independently and blindly evaluated each acquisition. Main Outcomes and Measures: Four primary end points were sequentially assessed: qualitative judgement about left ventricular size and function, right ventricular size, and the presence of a pericardial effusion. Secondary end points included 6 other clinical parameters and comparison of scans by nurses vs sonographers. Results: A total of 240 patients (mean [SD] age, 61 [16] years old; 139 men [57.9%]; 79 [32.9%] with body mass indexes >30) completed the study. Eight nurses each scanned 30 patients using the DL algorithm, producing studies judged to be of diagnostic quality for left ventricular size, function, and pericardial effusion in 237 of 240 cases (98.8%) and right ventricular size in 222 of 240 cases (92.5%). For the secondary end points, nurse and sonographer scans were not significantly different for most parameters. Conclusions and Relevance: This DL algorithm allows novices without experience in ultrasonography to obtain diagnostic transthoracic echocardiographic studies for evaluation of left ventricular size and function, right ventricular size, and presence of a nontrivial pericardial effusion, expanding the reach of echocardiography to clinical settings in which immediate interrogation of anatomy and cardiac function is needed and settings with limited resources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mitchell, C., Rahko, P. S., Blauwet, L. A., Canaday, B., Finstuen, J. A., Foster, M. C., Horton, K., Ogunyankin, K. O., Palma, R. A., & Velazquez, E. J. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2018.06.004 · Cited by 2,547
American college of emergency physicians
(1980) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(80)80511-7 · Cited by 1,545
Video-based AI for beat-to-beat assessment of cardiac function
Ouyang, D., He, B., Ghorbani, A., Yuan, N., Ebinger, J., Langlotz, C. P., Heidenreich, P. A., Harrington, R. A., Liang, D. H., Ashley, E. A., et al. (2020) · Nature · doi:10.1038/s41586-020-2145-8 · Cited by 1,153
Zhang, J., Gajjala, S., Agrawal, P., Tison, G. H., Hallock, L. A., Beussink-Nelson, L., Lassen, M. H., Fan, E., Aras, M. A., Jordan, C., et al. (2018) · Circulation · doi:10.1161/circulationaha.118.034338 · Cited by 1,006
Fast and accurate view classification of echocardiograms using deep learning
Madani, A., Arnaout, R., Mofrad, M., & Arnaout, R. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0013-1 · Cited by 585
Deep learning interpretation of echocardiograms
Ghorbani, A., Ouyang, D., Abid, A., He, B., Chen, J. H., Harrington, R. A., Liang, D. H., Ashley, E. A., & Zou, J. Y. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0216-8 · Cited by 518
Narula, S., Shameer, K., Salem Omar, A. M., Dudley, J. T., & Sengupta, P. P. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.08.062 · Cited by 410
American society of echocardiography
Ryan, T., & Khandheria, B. K. (2000) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(00)90052-x · Cited by 347
Knackstedt, C., Bekkers, S. C. A. M., Schummers, G., Schreckenberg, M., Muraru, D., Badano, L. P., Franke, A., Bavishi, C., Omar, A. M. S., & Sengupta, P. P. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.07.052 · Cited by 262
Kusunose, K., Abe, T., Haga, A., Fukuda, D., Yamada, H., Harada, M., & Sata, M. (2020) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.02.024 · Cited by 223
Sengupta, P. P., Huang, Y.-M., Bansal, M., Ashrafi, A., Fisher, M., Shameer, K., Gall, W., & Dudley, J. T. (2016) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.115.004330 · Cited by 203
Asch, F. M., Poilvert, N., Abraham, T., Jankowski, M., Cleve, J., Adams, M., Romano, N., Hong, H., Mor-Avi, V., Martin, R. P., et al. (2019) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.119.009303 · Cited by 194
Self-citationSanchez-Martinez, S., Duchateau, N., Erdei, T., Kunszt, G., Aakhus, S., Degiovanni, A., Marino, P., Carluccio, E., Piella, G., Fraser, A. G., et al. (2018) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.007138 · Cited by 144
Tabassian, M., Sunderji, I. D., Erdei, T., Sanchez‐Martinez, S., Degiovanni, A., Marino, P. N., Fraser, A. G., & D’hooge, J. (2018) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2018.07.013 · Cited by 139
Medvedofsky, D. A., Mor‐Avi, V., Amzulescu, M. S., Fernández‐Golfín, C., Hinojar, R., Monaghan, M. J., Otani, K., Reiken, J., Takeuchi, M., Tsang, W., et al. (2016) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jew328 · Cited by 125
Self-citationGenovese, D., Rashedi, N., Weinert, L., Narang, A., Addetia, K., Patel, A. R., Prater, D. M., Gonçalves, A., Mor‐Avi, V., & Lang, R. M. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.04.001 · Cited by 115
Self-citationUtilization of Artificial Intelligence in Echocardiography
Kusunose, K., Haga, A., Abe, T., & Sata, M. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0420 · Cited by 109
Mobile and pervasive computing technologies and the future of Alzheimer’s clinical trials
Doraiswamy, P. M., Narayan, V. A., & Manji, H. K. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0008-y · Cited by 97
Machine learning based automated dynamic quantification of left heart chamber volumes
Narang, A., Mor‐Avi, V., Prado, A. D., Volpato, V., Prater, D. M., Tamborini, G., Fusini, L., Pepi, M., Goyal, N., Addetia, K., et al. (2018) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jey137 · Cited by 93
Self-citationCOCATS 4 Task Force 5: Training in Echocardiography
Ryan, T., Berlacher, K. L., Lindner, J. R., Mankad, S. V., Rose, G. A., & Wang, A. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.035 · Cited by 74
Raghavendra, U., Acharya, U. R., Gudigar, A., Tan, J. H., Fujita, H., Hagiwara, Y., Molinari, F., Kongmebhol, P., & Ng, K. H. (2017) · Ultrasonics · doi:10.1016/j.ultras.2017.02.003 · Cited by 70
Multireader multicase variance analysis for binary data
Gallas, B. D., Pennello, G. A., & Myers, K. J. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.000b70 · Cited by 56
Automated, machine learning‐based, 3D echocardiographic quantification of left ventricular mass
Volpato, V., Mor‐Avi, V., Narang, A., Prater, D. M., Gonçalves, A., Tamborini, G., Fusini, L., Pepi, M., Patel, A. R., & Lang, R. M. (2018) · Echocardiography · doi:10.1111/echo.14234 · Cited by 52
Self-citationWiegers, S. E., Ryan, T., Arrighi, J. A., Brown, S. M., Canaday, B., Damp, J. B., Díaz‐Gómez, J. L., Figueredo, V. M., Garcia, M. J., Gillam, L. D., et al. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.04.002 · Cited by 35
Research works printed but not linked: 1
- American College of Cardiology. COVID-19 clinical guidance for the cardiovascular care team. Published 2020. Accessed March 23, 2020. https://www.acc.org/~/media/Non-Clinical/Files-PDFs-Excel-MS-Word-etc/2020/02/S20028-ACC-Clinical-Bulletin-Coronavirus.pdf
Cited by
Díaz-Gómez, J. L., Mayo, P. H., & Koenig, S. J. (2021) · New England Journal of Medicine · doi:10.1056/nejmra1916062 · Cited by 499
The current and future state of AI interpretation of medical images
Rajpurkar, P., & Lungren, M. P. (2023) · New England Journal of Medicine · doi:10.1056/nejmra2301725 · Cited by 443
Artificial Intelligence -based technologies in nursing: A scoping literature review of the evidence
von Gerich, H., Moen, H., Block, L. J., Chu, C. H., DeForest, H., Hobensack, M., Michalowski, M., Mitchell, J., Nibber, R., Olalia, M. A., et al. (2022) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2021.104153 · Cited by 360
“…2018 , Korach et al., 2020 , Ladios-Martin et al., 2020 , Lopes et al., 2013 , Mairittha et al., 2019; Moen et al., 2020b , Mufti et al., 2019 , Narang et al., 2021 , Nuutinen et al., 2020 , Oh et al., 2014 , Subramaniam and Dass, 2021 , Suominen et al., 2015 , Topaz et al., 2019a , Wang et…”
InfluentialData drift in medical machine learning: implications and potential remedies
Sahiner, B., Chen, W., Samala, R. K., & Petrick, N. (2023) · The British Journal of Radiology · doi:10.1259/bjr.20220878 · Cited by 279
Transforming Cardiovascular Care With Artificial Intelligence: From Discovery to Practice
Khera, R., Oikonomou, E. K., Nadkarni, G. N., Morley, J. R., Wiens, J., Butte, A. J., & Topol, E. J. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.05.003 · Cited by 264
Metadata
- Authors
- Narang, A., Bae, R., Hong, H., Thomas, Y., Surette, S., Cadieu, C., Chaudhry, A., Martin, R. P., McCarthy, P. M., Rubenson, D. S., Goldstein, S., Little, S. H., Lang, R. M., Weissman, N. J., & Thomas, J. D.
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2021-06-01
- Volume
- 6
- Issue
- 6
- Pages
- 624
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W3132346797
- Cited by
- 442
- References
- 24
- FWCI
- 13.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.