Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 61 of the 67 references it cites were found in a registry or an index.

Deep learning interpretation of echocardiograms

Open access

Published version of a preprint

Abstract

Echocardiography uses ultrasound technology to capture high temporal and spatial resolution images of the heart and surrounding structures, and is the most common imaging modality in cardiovascular medicine. Using convolutional neural networks on a large new dataset, we show that deep learning applied to echocardiography can identify local cardiac structures, estimate cardiac function, and predict systemic phenotypes that modify cardiovascular risk but not readily identifiable to human interpretation. Our deep learning model, EchoNet, accurately identified the presence of pacemaker leads (AUC = 0.89), enlarged left atrium (AUC = 0.86), left ventricular hypertrophy (AUC = 0.75), left ventricular end systolic and diastolic volumes ( $${R}^{2}$$ R 2 = 0.74 and $${R}^{2}$$ R 2 = 0.70), and ejection fraction ( $${R}^{2}$$ R 2 = 0.50), as well as predicted systemic phenotypes of age ( $${R}^{2}$$ R 2 = 0.46), sex (AUC = 0.88), weight ( $${R}^{2}$$ R 2 = 0.56), and height ( $${R}^{2}$$ R 2 = 0.33). Interpretation analysis validates that EchoNet shows appropriate attention to key cardiac structures when performing human-explainable tasks and highlights hypothesis-generating regions of interest when predicting systemic phenotypes difficult for human interpretation. Machine learning on echocardiography images can streamline repetitive tasks in the clinical workflow, provide preliminary interpretation in areas with insufficient qualified cardiologists, and predict phenotypes challenging for human evaluation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41746-019-0216-8

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 EchoNet machine learning pipeline for outcome prediction. a EchoNet workflow for image selection, cleaning, and model training. b Comparison of model performance with different cardiac views as input. c Examples of data augmentation. The original frame is rotated (left to right) and its intensity is increase (top to bottom) as augmentations.
Fig. 1 EchoNet machine learning pipeline for outcome prediction. a EchoNet workflow for image selection, cleaning, and model training. b Comparison of model performance with different cardiac views as input. c Examples of data augmentation. The original frame is rotated (left to right) and its intensity is increase (top to bottom) as augmentations.CC BY · PubMed Central
Fig. 2 EchoNet performance and interpretation for three clinical interpretations of local structures and features. For each task, representative positive examples are shown side-by-side with regions of interest from the respective model. Shaded areas indicate 95% confidence intervals.
Fig. 2 EchoNet performance and interpretation for three clinical interpretations of local structures and features. For each task, representative positive examples are shown side-by-side with regions of interest from the respective model. Shaded areas indicate 95% confidence intervals.CC BY · PubMed Central
Fig. 3 EchoNet performance and interpretation for ventricular size and function. EchoNet performance for a predicted left ventricular end systolic volume, b predicted end diastolic volume, c calculated ejection fraction from predicted ESV and EDV, and d predicted ejection fraction. e Input image, interpretation, and overlap for ejection fraction model.
Fig. 3 EchoNet performance and interpretation for ventricular size and function. EchoNet performance for a predicted left ventricular end systolic volume, b predicted end diastolic volume, c calculated ejection fraction from predicted ESV and EDV, and d predicted ejection fraction. e Input image, interpretation, and overlap for ejection fraction model.CC BY · PubMed Central
Fig. 4 EchoNet performance and interpretation for systemic phenotypes. a EchoNet performance for prediction of four systemic phenotypes (sex, weight, height and age) using apical-4-chamber view images. Shaded areas indicate 95% confidence intervals. b Interpretation of systemic phenotype models with representative positive examples shown side-by-side with regions of interest.
Fig. 4 EchoNet performance and interpretation for systemic phenotypes. a EchoNet performance for prediction of four systemic phenotypes (sex, weight, height and age) using apical-4-chamber view images. Shaded areas indicate 95% confidence intervals. b Interpretation of systemic phenotype models with representative positive examples shown side-by-side with regions of interest.CC BY · PubMed Central
Fig. 5 Bland-Altman plotsBland-Altman plots of EchoNet performance for regression predictiontasks. The solid black line indicates the median. Orange, red, and blue dashed lines delineate the central 50%, 75%, and 95% of cases based on differences between automated and measured values.
Fig. 5 Bland-Altman plotsBland-Altman plots of EchoNet performance for regression predictiontasks. The solid black line indicates the median. Orange, red, and blue dashed lines delineate the central 50%, 75%, and 95% of cases based on differences between automated and measured values.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 67 references

Research works printed but not linked: 1

  1. Madani, A., Ong, J. R., Tiberwal, A. & Mofrad, M. R. US hospital use of echocardiography: Insights from the nationwide inpatient sample. J. Am. Coll. Cardiol. 67, 502–511 (2016).

Cited by

See all 534

Metadata

Authors
Ghorbani, A., Ouyang, D., Abid, A., He, B., Chen, J. H., Harrington, R. A., Liang, D. H., Ashley, E. A., & Zou, J. Y.
Affiliations
  • Stanford University (US)
  • Stanford Medicine (US)
  • Chan Zuckerberg Biohub San Francisco (US)
Corresponding author
  • Ouyang, David
  • Zou, James Y.
Venue
npj Digital Medicine
Published
2020-01-24
Volume
3
Issue
1
Pages
10-10
ISSN
2398-6352 (ISSN-L)
OpenAlex
W3002705197
Cited by
518
References
67
Citations by year
2026: 68 · 2025: 91 · 2024: 95 · 2023: 91 · 2022: 75 · 2021: 60 · 2020: 36
FWCI
57.83
Type
journal article
Language
en
Open access
Licence
Locations
  • npj Digital Medicine (publishedVersion, cc-by)
  • bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nd)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
American College of Cardiology/ Merck Research Fellowship
Topics
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
Keywords
echocardiography, convolutional neural networks, cardiac structure segmentation, left ventricular hypertrophy, left atrial enlargement, ejection fraction estimation, cardiovascular risk prediction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep learning interpretation of echocardiograms. https://app.cochat.ai/papers/10.1038/s41746-019-0216-8
The paper
Ghorbani, A., Ouyang, D., Abid, A., He, B., Chen, J. H., Harrington, R. A., Liang, D. H., Ashley, E. A., & Zou, J. Y. (2020). Deep learning interpretation of echocardiograms. npj Digital Medicine. https://doi.org/10.1038/s41746-019-0216-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.