Performance of a Convolutional Neural Network and Explainability Technique for 12-Lead Electrocardiogram Interpretation
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Importance: Millions of clinicians rely daily on automated preliminary electrocardiogram (ECG) interpretation. Critical comparisons of machine learning-based automated analysis against clinically accepted standards of care are lacking. Objective: To use readily available 12-lead ECG data to train and apply an explainability technique to a convolutional neural network (CNN) that achieves high performance against clinical standards of care. Design, Setting, and Participants: This cross-sectional study was conducted using data from January 1, 2003, to December 31, 2018. Data were obtained in a commonly available 12-lead ECG format from a single-center tertiary care institution. All patients aged 18 years or older who received ECGs at the University of California, San Francisco, were included, yielding a total of 365 009 patients. Data were analyzed from January 1, 2019, to March 2, 2021. Exposures: A CNN was trained to predict the presence of 38 diagnostic classes in 5 categories from 12-lead ECG data. A CNN explainability technique called LIME (Linear Interpretable Model-Agnostic Explanations) was used to visualize ECG segments contributing to CNN diagnoses. Main Outcomes and Measures: Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were calculated for the CNN in the holdout test data set against cardiologist clinical diagnoses. For a second validation, 3 electrophysiologists provided consensus committee diagnoses against which the CNN, cardiologist clinical diagnosis, and MUSE (GE Healthcare) automated analysis performance was compared using the F1 score; AUC, sensitivity, and specificity were also calculated for the CNN against the consensus committee. Results: A total of 992 748 ECGs from 365 009 adult patients (mean [SD] age, 56.2 [17.6] years; 183 600 women [50.3%]; and 175 277 White patients [48.0%]) were included in the analysis. In 91 440 test data set ECGs, the CNN demonstrated an AUC of at least 0.960 for 32 of 38 classes (84.2%). Against the consensus committee diagnoses, the CNN had higher frequency-weighted mean F1 scores than both cardiologists and MUSE in all 5 categories (CNN frequency-weighted F1 score for rhythm, 0.812; conduction, 0.729; chamber diagnosis, 0.598; infarct, 0.674; and other diagnosis, 0.875). For 32 of 38 classes (84.2%), the CNN had AUCs of at least 0.910 and demonstrated comparable F1 scores and higher sensitivity than cardiologists, except for atrial fibrillation (CNN F1 score, 0.847 vs cardiologist F1 score, 0.881), junctional rhythm (0.526 vs 0.727), premature ventricular complex (0.786 vs 0.800), and Wolff-Parkinson-White (0.800 vs 0.842). Compared with MUSE, the CNN had higher F1 scores for all classes except supraventricular tachycardia (CNN F1 score, 0.696 vs MUSE F1 score, 0.714). The LIME technique highlighted physiologically relevant ECG segments. Conclusions and Relevance: The results of this cross-sectional study suggest that readily available ECG data can be used to train a CNN algorithm to achieve comparable performance to clinical cardiologists and exceed the performance of MUSE automated analysis for most diagnoses, with some exceptions. The LIME explainability technique applied to CNNs highlights physiologically relevant ECG segments that contribute to the CNN's diagnoses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mastering the game of Go with deep neural networks and tree search
Silver, D., Huang, A., Maddison, C. J., Guez, A., Sifre, L., van den Driessche, G., Schrittwieser, J., Antonoglou, I., Panneershelvam, V., Lanctot, M., et al. (2016) · Nature · doi:10.1038/nature16961 · Cited by 15,612
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Saito, T., & Rehmsmeier, M. (2015) · PLOS ONE · doi:10.1371/journal.pone.0118432 · Cited by 5,309
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Self-citationA Simple Generalisation of the Area Under the ROC Curve for Multiple Class Classification Problems
Hand, D. J., & Till, R. J. (2001) · Machine Learning · doi:10.1023/a:1010920819831 · Cited by 2,276
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613
Federated Learning for Healthcare Informatics
Xu, J., Glicksberg, B. S., Su, C., Walker, P., Bian, J., & Wang, F. (2021) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-020-00082-4 · Cited by 1,542
Federated Learning for Healthcare Informatics
Xu, J., Glicksberg, B. S., Su, C., Walker, P., Bian, J., & Wang, F. (2019) · arXiv · doi:10.48550/arxiv.1911.06270 · Cited by 1,538
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389
Samek, W., Wiegand, T., & Müller, K.-R. (2017) · arXiv · doi:10.48550/arxiv.1708.08296 · Cited by 1,080
Cited by
Kaur, D., Hughes, J. W., Rogers, A. J., Kang, G., Narayan, S. M., Ashley, E. A., & Perez, M. V. (2024) · Circulation: Heart Failure · doi:10.1161/circheartfailure.123.010879 · Cited by 58
“10 The application of artificial intelligence to ECG data has additionally been used to identify conditions that are not typically detected by the human eye.”
Self-citationExplaining Deep Learning for ECG Analysis: Building Blocks for Auditing and Knowledge Discovery
Wagner, P., Mehari, T., Haverkamp, W., & Strodthoff, N. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108525 · Cited by 48
Electrocardiogram Detection of Pulmonary Hypertension Using Deep Learning
ARAS, M. A., ABREAU, S., MILLS, H., RADHAKRISHNAN, L., KLEIN, L., MANTRI, N., RUBIN, B., BARRIOS, J., CHEHOUD, C., KOGAN, E., et al. (2023) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2022.12.016 · Cited by 46
Self-citationSerum Potassium Monitoring Using AI-Enabled Smartwatch Electrocardiograms
Chiu, I.-M., Wu, P.-J., Zhang, H., Hughes, J. W., Rogers, A. J., Jalilian, L., Perez, M., Lin, C.-H. R., Lee, C.-T., Zou, J., et al. (2024) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2024.07.023 · Cited by 31
Self-citation
Metadata
- Authors
- Hughes, J. W., Olgin, J. E., Avram, R., Abreau, S. A., Sittler, T., Radia, K., Hsia, H., Walters, T., Lee, B., Gonzalez, J. E., & Tison, G. H.
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2021-11-01
- Volume
- 6
- Issue
- 11
- Pages
- 1285
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W3188409561
- Cited by
- 127
- References
- 15
- FWCI
- 12.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of a Convolutional Neural Network and Explainability Technique for 12-Lead Electrocardiogram Interpretation. https://app.cochat.ai/papers/10.1001/jamacardio.2021.2746
- The paper
- Hughes, J. W., Olgin, J. E., Avram, R., Abreau, S. A., Sittler, T., Radia, K., Hsia, H., Walters, T., Lee, B., Gonzalez, J. E., & Tison, G. H. (2021). Performance of a Convolutional Neural Network and Explainability Technique for 12-Lead Electrocardiogram Interpretation. JAMA Cardiology. https://doi.org/10.1001/jamacardio.2021.2746
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.