CoChat

A Multimodal Video-Based AI Biomarker for Aortic Stenosis Development and Progression

Open access
Oikonomou, Evangelos K., Holste, Gregory, Yuan, Neal, Coppi, Andreas, McNamara, Robert L., Haynes, Norrisa A., Vora, Amit N., Velazquez, Eric J., Li, Fan, Menon, Venu, Kapadia, Samir R., Gill, Thomas M., Nadkarni, Girish N., Krumholz, Harlan M., Wang, Zhangyang, Ouyang, David, Khera, Rohan · 2024 · JAMA Cardiology
Cited by 61

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Importance: Aortic stenosis (AS) is a major public health challenge with a growing therapeutic landscape, but current biomarkers do not inform personalized screening and follow-up. A video-based artificial intelligence (AI) biomarker (Digital AS Severity index [DASSi]) can detect severe AS using single-view long-axis echocardiography without Doppler characterization. Objective: To deploy DASSi to patients with no AS or with mild or moderate AS at baseline to identify AS development and progression. Design, Setting, and Participants: This is a cohort study that examined 2 cohorts of patients without severe AS undergoing echocardiography in the Yale New Haven Health System (YNHHS; 2015-2021) and Cedars-Sinai Medical Center (CSMC; 2018-2019). A novel computational pipeline for the cross-modal translation of DASSi into cardiac magnetic resonance (CMR) imaging was further developed in the UK Biobank. Analyses were performed between August 2023 and February 2024. Exposure: DASSi (range, 0-1) derived from AI applied to echocardiography and CMR videos. Main Outcomes and Measures: Annualized change in peak aortic valve velocity (AV-V max) and late (>6 months) aortic valve replacement (AVR). Results: A total of 12 599 participants were included in the echocardiographic study (YNHHS: n = 8798; median [IQR] age, 71 [60-80] years; 4250 [48.3%] women; median [IQR] follow-up, 4.1 [2.4-5.4] years; and CSMC: n = 3801; median [IQR] age, 67 [54-78] years; 1685 [44.3%] women; median [IQR] follow-up, 3.4 [2.8-3.9] years). Higher baseline DASSi was associated with faster progression in AV-V max (per 0.1 DASSi increment: YNHHS, 0.033 m/s per year [95% CI, 0.028-0.038] among 5483 participants; CSMC, 0.082 m/s per year [95% CI, 0.053-0.111] among 1292 participants), with values of 0.2 or greater associated with a 4- to 5-fold higher AVR risk than values less than 0.2 (YNHHS: 715 events; adjusted hazard ratio [HR], 4.97 [95% CI, 2.71-5.82]; CSMC: 56 events; adjusted HR, 4.04 [95% CI, 0.92-17.70]), independent of age, sex, race, ethnicity, ejection fraction, and AV-V max. This was reproduced across 45 474 participants (median [IQR] age, 65 [59-71] years; 23 559 [51.8%] women; median [IQR] follow-up, 2.5 [1.6-3.9] years) undergoing CMR imaging in the UK Biobank (for participants with DASSi ≥0.2 vs those with DASSi <.02, adjusted HR, 11.38 [95% CI, 2.56-50.57]). Saliency maps and phenome-wide association studies supported associations with cardiac structure and function and traditional cardiovascular risk factors. Conclusions and Relevance: In this cohort study of patients without severe AS undergoing echocardiography or CMR imaging, a new AI-based video biomarker was independently associated with AS development and progression, enabling opportunistic risk stratification across cardiovascular imaging modalities as well as potential application on handheld devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamacardio.2024.0595

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 61

Metadata

Authors
Oikonomou, E. K., Holste, G., Yuan, N., Coppi, A., McNamara, R. L., Haynes, N. A., Vora, A. N., Velazquez, E. J., Li, F., Menon, V., Kapadia, S. R., Gill, T. M., Nadkarni, G. N., Krumholz, H. M., Wang, Z., Ouyang, D., & Khera, R.
Venue
JAMA Cardiology
Published
2024-06-01
Volume
9
Issue
6
Pages
534
ISSN
2380-6583 (ISSN-L)
OpenAlex
W4394009815
Cited by
61
References
11
FWCI
16.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Multimodal Video-Based AI Biomarker for Aortic Stenosis Development and Progression. https://app.cochat.ai/papers/10.1001/jamacardio.2024.0595
The paper
Oikonomou, E. K., Holste, G., Yuan, N., Coppi, A., McNamara, R. L., Haynes, N. A., Vora, A. N., Velazquez, E. J., Li, F., Menon, V., Kapadia, S. R., Gill, T. M., Nadkarni, G. N., Krumholz, H. M., Wang, Z., Ouyang, D., & Khera, R. (2024). A Multimodal Video-Based AI Biomarker for Aortic Stenosis Development and Progression. JAMA Cardiology. https://doi.org/10.1001/jamacardio.2024.0595

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.