Determination of Feasibility and Utility of Microscope-Integrated Optical Coherence Tomography During Ophthalmic Surgery: The DISCOVER Study RESCAN Results
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Optical coherence tomography (OCT) has transformed the clinical management of a myriad of ophthalmic conditions. Applying OCT to ophthalmic surgery may have implications for surgical decision making and patient outcomes. OBJECTIVE: To assess the feasibility and effect on surgical decision making of a microscope-integrated intraoperative OCT (iOCT) system. DESIGN, SETTING, AND PARTICIPANTS: Report highlighting the 1-year results (March 2014-February 2015) of the RESCAN 700 portion of the DISCOVER (Determination of Feasibility of Intraoperative Spectral Domain Microscope Combined/Integrated OCT Visualization During En Face Retinal and Ophthalmic Surgery) study, a single-site, multisurgeon, prospective consecutive case series regarding this investigational device. Participants included patients undergoing ophthalmic surgery. Data on clinical characteristics were collected, and iOCT was performed during surgical milestones, as directed by the operating surgeon. A surgeon questionnaire was issued to each surgeon and was completed after each case to evaluate the role of iOCT during surgery and its particular role in select surgical procedures. MAIN OUTCOMES AND MEASURES: Percentage of cases with successful acquisition of iOCT (ie, feasibility). Percentage of cases in which iOCT altered surgical decision making (ie, utility). RESULTS: During year 1 of the DISCOVER study, a total of 227 eyes (91 anterior segment cases and 136 posterior segment cases) underwent imaging with the RESCAN 700 system. Successful imaging (eg, the ability to acquire an OCT image of the tissue of interest) was obtained for 224 of 227 eyes (99% [95% CI, 98%-100%]). During lamellar keratoplasty, the iOCT data provided information that altered the surgeon's decision making in 38% of the cases (eg, complete graft apposition when the surgeon believed there was interface fluid). In membrane peeling procedures, iOCT information was discordant with the surgeon's impression of membrane peel completeness in 19% of cases (eg, lack of residual membrane or presence of occult membrane), thus affecting additional surgical maneuvers. CONCLUSIONS AND RELEVANCE: The DISCOVER study demonstrates the feasibility of real-time iOCT with a microscope-integrated iOCT system for ophthalmic surgery. The information gained from iOCT appears to allow surgeons to assess subtle details in a unique perspective from standard en face visualization, which can affect surgical decision making some of the time, although the effect of these changes in decision making on outcomes remains unknown. A prospective randomized masked trial is needed to confirm these results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cook, R. J., Dickens, B. M., & Fathalla, M. F. (2003) · Reproductive Health and Human Rights · doi:10.1093/acprof:oso/9780199241323.003.0025 · Cited by 10,769
(2014) · Journal of the Korean Medical Association · doi:10.5124/jkma.2014.57.11.899 · Cited by 2,566
Ehlers, J. P., Dupps, W. J., Kaiser, P. K., Goshe, J., Singh, R. P., Petkovsek, D., & Srivastava, S. K. (2014) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2014.07.034 · Cited by 225 · cited 1×
“Scleral buckle without PPV 0 (0) 1 (1)”
Self-citationSteven, P., Le Blanc, C., Velten, K., Lankenau, E., Krug, M., Oelckers, S., Heindl, L. M., Gehlsen, U., Hüttmann, G., & Cursiefen, C. (2013) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.4672 · Cited by 190 · cited 1×
“Proliferative diabetic retinopathy 0 (0) 12 (9)”
DAYANI, P. N., MALDONADO, R., FARSIU, S., & TOTH, C. A. (2009) · Retina · doi:10.1097/iae.0b013e3181b266bc · Cited by 160
FEASIBILITY OF INTRASURGICAL SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
Binder, S., Falkner-Radler, C. I., Hauger, C. G., Matz, H., & Glittenberg, C. G. (2011) · Retina · doi:10.1097/iae.0b013e3182019c18 · Cited by 152
Ray, R., Barañano, D. E., Fortun, J. A., Schwent, B. J., Cribbs, B. E., Bergstrom, C. S., Hubbard, G. B., & Srivastava, S. K. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.04.012 · Cited by 149 · cited 1×
“Failed penetrating keratoplasty 7 (8) 0 (0)”
Self-citationEhlers, J. P., Tao, Y. K. K., Farsiu, S., Maldonado, R. S., Izatt, J. A., & Toth, C. A. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6720 · Cited by 145
Self-citationEhlers, J. P., Kaiser, P. K., & Srivastava, S. K. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2014-305294 · Cited by 131
Self-citationEhlers, J. P., Srivastava, S. K., Feiler, D. L., Noonan, A. I., Rollins, A. M., & Tao, Y. K. K. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105224 · Cited by 120
Self-citationEhlers, J. P., Tam, T., Kaiser, P. K., Martin, D. F., Smith, G., & Srivastava, S. K. (2014) · Retina · doi:10.1097/iae.0000000000000123 · Cited by 108
Self-citationINTRASURGICAL DYNAMICS OF MACULAR HOLE SURGERY
Ehlers, J. P., Xu, D. N., Kaiser, P. K., Singh, R. P., & Srivastava, S. K. (2013) · Retina · doi:10.1097/iae.0b013e318297daf3 · Cited by 106
Self-citationAnterior Segment Optical Coherence Tomography–Guided Big-Bubble Technique
Scorcia, V., Busin, M., Lucisano, A., Beltz, J., Carta, A., & Scorcia, G. B. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.08.041 · Cited by 95
Tao, Y. K. K., Srivastava, S. K., & Ehlers, J. P. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.001877 · Cited by 93
Self-citationEhlers, J. P., Ohr, M. P., Kaiser, P. K., & Srivastava, S. K. (2013) · Retina · doi:10.1097/iae.0b013e31828396b7 · Cited by 85
Self-citationThe value of intraoperative optical coherence tomography imaging in vitreoretinal surgery
Ehlers, J. P., Tao, Y. K. K., & Srivastava, S. K. (2014) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000044 · Cited by 77
Self-citationHahn, P., Migacz, J. V., O’Connell, R. V., Day, S., Lee, A., Lin, P., Vann, R. R., Kuo, A. N., Fekrat, S., Mruthyunjaya, P., et al. (2013) · Retina · doi:10.1097/iae.0b013e3182831293 · Cited by 75
Juthani, V. V., Goshe, J. M., Srivastava, S. K., & Ehlers, J. P. (2014) · Cornea · doi:10.1097/ico.0000000000000209 · Cited by 62
Self-citationXu, D. N., Yuan, A., Kaiser, P. K., Srivastava, S. K., Singh, R. P., Sears, J. E., Martin, D. F., & Ehlers, J. P. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10246 · Cited by 56
Self-citationIntraoperative SD-OCT in Macular Surgery
Pichi, F., Alkabes, M., Nucci, P., & Ciardella, A. P. (2012) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/15428877-20121001-08 · Cited by 46 · cited 1×
“Full-thickness macular hole 0 (0) 10 (7)”
Ehlers, J. P., Itoh, Y., Xu, L. T., Kaiser, P. K., Singh, R. P., & Srivastava, S. K. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15765 · Cited by 43
Self-citationXu, D. N., Dupps, W. J., Srivastava, S. K., & Ehlers, J. P. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14346 · Cited by 31
Self-citation
Cited by
Intraoperative optical coherence tomography: past, present, and future
Ehlers, J. P. (2016) · Eye · doi:10.1038/eye.2015.255 · Cited by 77
Self-citationHuman/robotic interaction: vision limits performance in simulated vitreoretinal surgery
de Smet, M. D., de Jonge, N., Iannetta, D., Faridpooya, K., van Oosterhout, E., Naus, G., Meenink, T. C. M., Mura, M., & Beelen, M. J. (2019) · Acta Ophthalmologica · doi:10.1111/aos.14003 · Cited by 13
“A surgeon’s use of heads-up displays can improve his depth perception (Eckardt & Paulo 2016), while the intraoperative OCT can improve his ability to position robotic instruments within the eye (Ehlers et al. 2015; Siebelmann et al. 2016).”
Background
Metadata
- Authors
- Ehlers, J. P., Goshe, J., Dupps, W. J., Kaiser, P. K., Singh, R. P., Gans, R., Eisengart, J., & Srivastava, S. K.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2015-10-01
- Volume
- 133
- Issue
- 10
- Pages
- 1124
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W1882869569
- Cited by
- 170
- References
- 22
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.