Characterization of Drusen and Hyperreflective Foci as Biomarkers for Disease Progression in Age-Related Macular Degeneration Using Artificial Intelligence in Optical Coherence Tomography
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Importance: The morphologic changes and their pathognomonic distribution in progressing age-related macular degeneration (AMD) are not well understood. Objectives: To characterize the pathognomonic distribution and time course of morphologic patterns in AMD and to quantify changes distinctive for progression to macular neovascularization (MNV) and macular atrophy (MA). Design, Setting, and Participants: This cohort study included optical coherence tomography (OCT) volumes from study participants with early or intermediate AMD in the fellow eye in the HARBOR (A Study of Ranibizumab Administered Monthly or on an As-needed Basis in Patients With Subfoveal Neovascular Age-Related Macular Degeneration) trial. Patients underwent imaging monthly for 2 years (July 1, 2009, to August 31, 2012) following a standardized protocol. Data analysis was performed from June 1, 2018, to January 21, 2020. Main Outcomes and Measures: To obtain topographic correspondence between patients and over time, all scans were mapped into a joint reference frame. The time of progression to MNV and MA was established, and drusen volumes and hyperreflective foci (HRF) volumes were automatically segmented in 3 dimensions using validated artificial intelligence algorithms. Topographically resolved population means of these markers were constructed by averaging quantified drusen and HRF maps in the patient subgroups. Results: Of 1097 patients enrolled in HARBOR, 518 (mean [SD] age, 78.1 [8.2] years; 309 [59.7%] female) had early or intermediate AMD in the fellow eye at baseline. During the 24-month follow-up period, 135 (26%) eyes developed MNV, 50 eyes (10%) developed MA, and 333 (64%) eyes did not progress to advanced AMD. Drusen and HRF had distinct topographic patterns. Mean drusen thickness at the fovea was 29.6 μm (95% CI, 20.2-39.0 μm) for eyes progressing to MNV, 17.2 μm (95% CI, 9.8-24.6 μm) for eyes progressing to MA, and 17.1 μm (95% CI, 12.5-21.7 μm) for eyes without disease progression. At 0.5-mm eccentricity, mean drusen thickness was 25.8 μm (95% CI, 19.1-32.5 μm) for eyes progressing to MNV, 21.7 μm (95% CI, 14.6-28.8 μm) for eyes progressing to MA, and 14.4 μm (95% CI, 11.2-17.6 μm) for eyes without disease progression. The mean HRF thickness at the foveal center was 0.072 μm (95% CI, 0-0.152 μm) for eyes progressing to MNV, 0.059 μm (95% CI, 0-0.126 μm) for eyes progressing to MA, and 0.044 μm (95% CI, 0.007-0.081) for eyes without disease progression. At 0.5-mm eccentricity, the largest mean HRF thickness was seen in eyes progressing to MA (0.227 μm; 95% CI, 0.104-0.349 μm) followed by eyes progressing to MNV (0.161 μm; 95% CI, 0.101-0.221 μm) and eyes without disease progression (0.085 μm; 95% CI, 0.058-0.112 μm). Conclusions and Relevance: In this study, drusen and HRF represented imaging biomarkers of disease progression in AMD, demonstrating distinct topographic patterns over time that differed between eyes progressing to MNV, eyes progressing to MA, or eyes without disease progression. Automated localization and precise quantification of these factors may help to develop reliable methods of predicting future disease progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cook, R. J., Dickens, B. M., & Fathalla, M. F. (2003) · Reproductive Health and Human Rights · doi:10.1093/acprof:oso/9780199241323.003.0025 · Cited by 10,769
De Cillà, S. D., Farruggio, S., Vujosevic, S., Raina, G., Filippini, D., Gatti, V., Clemente, N., Mary, D., Vezzola, D., Casini, G., et al. (2017) · Cellular Physiology and Biochemistry · doi:10.1159/000479441 · Cited by 5,136
Clinical Classification of Age-related Macular Degeneration
Ferris, F. L., Wilkinson, C. P., Bird, A., Chakravarthy, U., Chew, E., Csaky, K., & Sadda, S. R. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.10.036 · Cited by 1,863
Age-related macular degeneration
Lim, L. S., Mitchell, P., Seddon, J. M., Holz, F. G., & Wong, T. Y. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60282-7 · Cited by 1,717
Consensus Definition for Atrophy Associated with Age-Related Macular Degeneration on OCT
Sadda, S. R., Guymer, R., Holz, F. G., Schmitz-Valckenberg, S., Curcio, C. A., Bird, A. C., Blodi, B. A., Bottoni, F., Chakravarthy, U., Chew, E. Y., et al. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.09.028 · Cited by 922
A Simplified Severity Scale for Age-Related Macular Degeneration: AREDS Report No. 18
(2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.11.1570 · Cited by 807
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
Self-citationHo, A. C., Busbee, B. G., Regillo, C. D., Wieland, M. R., Van Everen, S. A., Li, Z., Rubio, R. G., & Lai, P. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.05.009 · Cited by 590
Deep learning in ophthalmology: The technical and clinical considerations
Ting, D. S. W., Peng, L., Varadarajan, A. V., Keane, P. A., Burlina, P. M., Chiang, M. F., Schmetterer, L., Pasquale, L. R., Bressler, N. M., Webster, D. R., et al. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2019.04.003 · Cited by 534
Cited by
Age-related macular degeneration
Fleckenstein, M., Keenan, T. D. L., Guymer, R. H., Chakravarthy, U., Schmitz-Valckenberg, S., Klaver, C. C., Wong, W. T., & Chew, E. Y. (2021) · Nature Reviews Disease Primers · doi:10.1038/s41572-021-00265-2 · Cited by 978
Age-related macular degeneration
Guymer, R. H., & Campbell, T. G. (2023) · The Lancet · doi:10.1016/s0140-6736(22)02609-5 · Cited by 502
AI in diagnostic imaging: Revolutionising accuracy and efficiency
Khalifa, M., & Albadawy, M. (2024) · Computer Methods and Programs in Biomedicine Update · doi:10.1016/j.cmpbup.2024.100146 · Cited by 517
Age-Related Macular Degeneration: Pathophysiology, Management, and Future Perspectives
Flores, R., Carneiro, Â., Vieira, M., Tenreiro, S., & Seabra, M. C. (2021) · Ophthalmologica · doi:10.1159/000517520 · Cited by 173
Sura, A. A., Chen, L., Messinger, J. D., Swain, T. A., McGwin, G., Freund, K. B., & Curcio, C. A. (2020) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.61.13.19 · Cited by 148
Retinal Progression Biomarkers of Early and Intermediate Age-Related Macular Degeneration
Flores, R., Carneiro, Â., Tenreiro, S., & Seabra, M. C. (2021) · Life · doi:10.3390/life12010036 · Cited by 42
Trinh, M., Kalloniatis, M., Alonso-Caneiro, D., & Nivison-Smith, L. (2022) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.63.5.36 · Cited by 29
Trinh, M., Khou, V., Kalloniatis, M., & Nivison-Smith, L. (2021) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.62.13.13 · Cited by 14
Metadata
- Authors
- Waldstein, S. M., Vogl, W.-D., Bogunovic, H., Sadeghipour, A., Riedl, S., & Schmidt-Erfurth, U.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2020-07-01
- Volume
- 138
- Issue
- 7
- Pages
- 740
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W3022543352
- Cited by
- 203
- References
- 35
- FWCI
- 15.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.