Assays for Determination of Protein Concentration
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Biochemical analysis of proteins relies on accurate quantitation of protein concentration. This appendix describes how to perform commonly used protein assays, e.g., Lowry, Bradford, BCA, and UV spectroscopic protein assays. The primary focus of the appendix is assay selection, emphasizing sample and buffer compatibility. Protein assay standard curves and data processing fundamentals are discussed in detail. This appendix also details high‐throughput adaptations of the commonly used protein assays, and also contains a protocol for BCA assay of total protein in SDS‐PAGE sample buffer that is used for equal loading of SDS‐PAGE gels, which is reliable, inexpensive, and quick. Curr. Protoc. Pharmacol. 38:A.3A.1‐A.3A.29. © 2007 by John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of protein using bicinchoninic acid
Smith, P. K., Krohn, R. I., Hermanson, G. T., Mallia, A. K., Gartner, F. H., Provenzano, M. D., Fujimoto, E. K., Goeke, N. M., Olson, B. J., & Klenk, D. C. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90442-7 · Cited by 18,482
Self-citationStoscheck, C. M. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)82008-p · Cited by 1,438
Wiechelman, K. J., Braun, R. D., & Fitzpatrick, J. D. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90383-1 · Cited by 766 · cited 1×
“Originally, the mechanism of the BCA assay was thought to be similar to the Lowry assay, but it is now known that there are two distinct reactions that take place with copper ions unique to the BCA assay (Wiechelman et al., 1988).”
ResultHow to prevent losses of protein by adsorption to glass and plastic
Suelter, C. H., & DeLuca, M. (1983) · Analytical Biochemistry · doi:10.1016/0003-2697(83)90738-8 · Cited by 105
Cited by
Chapter 8 Quantitation of Protein
Noble, J. E., & Bailey, M. J. A. (2009) · Methods in Enzymology · doi:10.1016/s0076-6879(09)63008-1 · Cited by 492
Roberts, C. A., Al-Tameemi, H. M., Mashruwala, A. A., Rosario-Cruz, Z., Chauhan, U., Sause, W. E., Torres, V. J., Belden, W. J., & Boyd, J. M. (2017) · Infection and Immunity · doi:10.1128/iai.00100-17 · Cited by 84
Mashruwala, A. A., Pang, Y. Y., Rosario‐Cruz, Z., Chahal, H. K., Benson, M. A., Mike, L. A., Skaar, E. P., Torres, V. J., Nauseef, W. M., & Boyd, J. M. (2015) · Molecular Microbiology · doi:10.1111/mmi.12860 · Cited by 79
Wang, G., Zhang, M., Zhao, J., Xia, Y., Lai, P. F.-H., & Ai, L. (2018) · Frontiers in Microbiology · doi:10.3389/fmicb.2018.02858 · Cited by 58
Bacillithiol has a role in Fe–S cluster biogenesis in Staphylococcus aureus
Rosario‐Cruz, Z., Chahal, H. K., Mike, L. A., Skaar, E. P., & Boyd, J. M. (2015) · Molecular Microbiology · doi:10.1111/mmi.13115 · Cited by 50
Metadata
- Authors
- Olson, B. J. S. C., & Markwell, J.
- Venue
- Current Protocols in Pharmacology
- Publisher
- Wiley
- Published
- 2007-09
- Volume
- 38
- Issue
- 1
- Pages
- 3A-3A
- ISSN
- 1934-8282 (ISSN-L)
- 1934-8290
- OpenAlex
- W1843243568
- Cited by
- 244
- References
- 4
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.