Compensation in Flow Cytometry
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Many people using multi‐color flow cytometry do not understand what compensation is, when it is needed, or how it should be applied. The author provides a clear explanation of the nature of compensation, the factors that affect compensation values, and the effect of compensation on data visualization. Both hardware and software compensation are covered. Although the subject is treated from a mathematical perspective, the manner of presentation is very straightforward. The unit discusses appropriate controls and protocols to check compensation settings, as well as introducing the concept of fluorescence‐minus‐one gates. Many example figures are supplied to give the reader a clear indication of how the author believes compensation should be handled. Keywords: flow cytometry; spectral compensation; fluorescence spillover; autofluorescence; fluorescence minus one
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is not possible to interpret data from multiparameter flow cytometry without including these essential controls [6].”
From Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition) (2021) · cites this paper as [6]
Citations
Cites
Spectral compensation for flow cytometry: Visualization artifacts, limitations, and caveats
Roederer, M. (2001) · Cytometry · doi:10.1002/1097-0320(20011101)45:3<194::aid-cyto1163>3.0.co;2-c · Cited by 558 · cited 2×
“While there are small errors in the electronics that can contribute to this spread, the most significant source of error is photon-counting statistics (Roederer, 2001).”
BackgroundSelf-citationTwo-color immunofluorescence using a fluorescence-activated cell sorter.
Loken, M. R., Parks, D. R., & Herzenberg, L. A. (1977) · Journal of Histochemistry & Cytochemistry · doi:10.1177/25.7.330738 · Cited by 193
Fluorescence Spectral Overlap Compensation for Any Number of Flow Cytometry Parameters
Bagwell, C. B., & Adams, E. G. (1993) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1993.tb38775.x · Cited by 157 · cited 1×
“This topic is dealt with in detail by Bagwell and Adams (1993).”
BackgroundHandbook of Experimental Immunology
Mellors, R. C. (1969) · American Journal of Clinical Pathology · doi:10.1093/ajcp/51.5.657 · Cited by 105
A single laser method for subtraction of cell autofluorescence in flow cytometry
Alberti, S., Parks, D. R., & Herzenberg, L. A. (1987) · Cytometry · doi:10.1002/cyto.990080203 · Cited by 98
Roederer, M., & Murphy, R. F. (1986) · Cytometry · doi:10.1002/cyto.990070610 · Cited by 95 · cited 1×
“Autofluorescence compensation is more fully described in published references by Roederer and Murphy (1986) and Alberti et al. (1987).”
BackgroundSelf-citation
Cited by
Items 101–200 of 235
Multiparameter Conventional Flow Cytometry
McKinnon, K. M. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-7346-0_8 · Cited by 19
“To combat this, fluorescence minus one (FMO) controls should be used whenever possible [5].”
MethodSalinas, T. R. W., Gosselin, A., Marchand, L. R., Gabriel, E. M., Tastet, O., Goulet, J.-P., Zhang, Y., Vlad, D., Touil, H., Routy, J., et al. (2021) · iScience · doi:10.1016/j.isci.2021.103225 · Cited by 18
Improved compensation in flow cytometry by multivariable optimization
Sugár, I. P., González‐Lergier, J., & Sealfon, S. C. (2011) · Cytometry Part A · doi:10.1002/cyto.a.21062 · Cited by 18
“The use of multi-stained samples for compensation was first proposed by Roederer and Murphy (2).”
MethodInfluentialMonserrat, J., Heras, C. B., Gomez-Lahoz, A. M., Movasat, A., Pérez, A., Ruiz, L., Díaz, D., Chara, L. E., Sánchez, A. I., Albarrán, F., et al. (2019) · Cells · doi:10.3390/cells8080871 · Cited by 18
“[48]; the flow cytometry results are presented following the guidelines of the International Society of Advancement of Cytometry (ISAC) [49].”
MethodZhang, W., Nilles, T. L., Johnson, J. R., & Margolick, J. B. (2015) · The Journals of Gerontology Series A · doi:10.1093/gerona/glv132 · Cited by 17
“Ethnicity Black 0 (0)*,‡ 5 (28) 5† (12) 4‡ (19) 10 (56) 14 (36) White 22 (100) 13 (72) 35 (88) 17 (81) 8 (44) 25 (64) Diabetes mellitus No 18‡ (82) 9 (50) 27 (68) 15 (71) 12 (67) 27 (69) Yes 1 (5) 7 (39) 8 (20) 2 (10) 3 (17) 5 (13) Unknown 3 (14) 2 (11) 5 (12) 4 (19) 3 (17) 7 (18) Hepatitis C status Negative 21 (95) 1…”
Far, M. E., Ancuța, P., Routy, J., Zhang, Y., Bakeman, W., Bordi, R., DaFonseca, S., Said, E. A., Gosselin, A., Tep, T.-S., et al. (2015) · Journal of General Virology · doi:10.1099/vir.0.000065 · Cited by 17
Quantitative Fluorescence Measurements with Multicolor Flow Cytometry
Wang, L., Gaigalas, A. K., & Wood, J. C. S. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-7346-0_6 · Cited by 17
Stripping flow cytometry: How many detectors do we need for bacterial identification?
Rubbens, P., Props, R., García‐Timermans, C., Boon, N., & Waegeman, W. (2017) · Cytometry Part A · doi:10.1002/cyto.a.23284 · Cited by 20
“As this information is often neglected based on a theoretical point of view, most researchers are interested in compensating for this effect in multicolor experiments (16–18).”
BackgroundSpectral Flow Cytometry: The Current State and Future of the Technology
Astakhova, E. A., Gubaeva, A., Naumova, D. A., Egorova, A., Maznina, A. A., Rybkina, I. G., Osmanov, I. M., Tabakov, D., Mityaeva, O. N., & Volchkov, P. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26125911 · Cited by 20
“There is a wide variety of recommendations for compensation optimization, with their number increasing every year [48].”
Update on Acute Leukemias of Ambiguous Lineage
Aggarwal, N., & Weinberg, O. K. (2021) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2021.03.016 · Cited by 16
SAIBR: a simple, platform-independent method for spectral autofluorescence correction
Rodrigues, N. T. L., Bland, T., Borrego-Pinto, J., Ng, K., Hirani, N., Gu, Y., Foo, S., & Goehring, N. W. (2022) · Development · doi:10.1242/dev.200545 · Cited by 16
Ganesh, A., Lemongello, D., Lee, E., Peterson, J. J., McLaughlin, B. E., Ferre, A. L., Gillespie, G. M. A., Fuchs, D., Deeks, S. G., Hunt, P. W., et al. (2016) · AIDS Research and Human Retroviruses · doi:10.1089/aid.2015.0313 · Cited by 16
“Bivariate plots were constructed using ‘‘fluorescence minus one’’ controls to confirm placement of individual gates.(42) Statistical analyses were performed using GraphPad Prism software (GraphPad software, San Diego, CA).”
Mao, L., Boddeda, S. R., Chen, B., Zeng, Q., Schoeb, T. R., Velazquez, V. M., & Shimamura, M. (2018) · American Journal of Transplantation · doi:10.1111/ajt.14868 · Cited by 15
Fox, A. C., Dutt, T. S., Karger, B. R., Rojas, M., Obregón‐Henao, A., Anderson, G. B., & Henao-Tamayo, M. I. (2020) · Scientific Reports · doi:10.1038/s41598-020-64516-0 · Cited by 18
“When there is good separation between the positive and negative populations within a marker, it is acceptable to base the MFI cutoffs on the sample data 12 .”
BackgroundMethodInfluentialVirk, H., Rana, S., Sharma, P. R. N., Bose, P. L., Yadav, D. D., Sachdeva, M. U. S., Varma, N., Trehan, A., Lad, D. P., Khadwal, A., et al. (2021) · Annals of Hematology · doi:10.1007/s00277-021-04574-0 · Cited by 17
“The expression of TSLPR was determined by fluorescence minus one (FMO) method [6, 7].”
MethodArroyo, E., Tagesen, E. C., Hart, T. L., Miller, B. A., & Jajtner, A. R. (2022) · Brain Behavior & Immunity - Health · doi:10.1016/j.bbih.2022.100415 · Cited by 15
“Unstained blood samples and fluorescence-minus-one (FMO) controls were used to determine optimal gate positions (Roederer, 2002).”
MethodAbsolute Quantification of Plasma Membrane Receptors Via Quantitative Flow Cytometry
Fang, Y., Malik, M., England, S. K., & Imoukhuede, P. I. (2022) · Methods in molecular biology · doi:10.1007/978-1-0716-2217-9_4 · Cited by 15
Udomkarnjananun, S., Francke, M. I., Dieterich, M., van de Velde, D., Litjens, N. H. R., Boer, K., de Winter, B. C. M., Baan, C. C., & Hesselink, D. A. (2022) · Transplantation · doi:10.1097/tp.0000000000004287 · Cited by 17
“The percentage of cytokine-positive cells was compared between the samples with and without verapamil by using the fluorescence-minus-one gating strategy.(30) Figure S2 (SDC, http://links.”
MethodDynamic Proliferation Assessment in Flow Cytometry
Diermeier‐Daucher, S., & Brockhoff, G. (2010) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb0806s48 · Cited by 15
“If the experimenter wants to check whether compensation is needed with the specific experimental system, prepare unstained, singlestained, and one triple-stained sample and refer to Roederer (2002) for the procedure of compensation.”
BackgroundMethodShevchenko, Y., Lurje, I., Tacke, F., & Hammerich, L. (2024) · Cytometry Part A · doi:10.1002/cyto.a.24836 · Cited by 14
“In this case, compensation beads show some significant advantages as they bind a consistent amount of antibody independent of its specificity [13].”
BackgroundDias, J., Cattin, A., Bendoumou, M., Dutilleul, A., Lodge, R., Goulet, J.-P., Fert, A., Marchand, L. R., Salinas, T. R. W., Yoka, C. D. N., et al. (2024) · Cell Reports · doi:10.1016/j.celrep.2024.114414 · Cited by 15
Mage, P. L., Konecny, A., & Mair, F. (2026) · Cytometry Part A · doi:10.1002/cyto.a.70044 · Cited by 14
“The impact of SSE on biological resolution must be managed through careful panel design [10–12] and appropriate staining controls such as fluorescence- minus-one (FMO) samples [13, 14].”
Acquisition of High‐Quality Spectral Flow Cytometry Data
Fox, A. C., Dutt, T. S., Karger, B. R., Obregón‐Henao, A., Anderson, G. B., & Henao-Tamayo, M. I. (2020) · Current Protocols in Cytometry · doi:10.1002/cpcy.74 · Cited by 14
“Fluorescent minus one (FMO) controls are an example of a “best practice” control used in both conventional flow cytometry and spectral flow cytometry (Current Protocols article: Roederer, 2002).”
BackgroundMethodMonserrat, J., Heras, C. B., Gomez-Lahoz, A. M., Movasat, A., Pérez, A., Ruiz, L., Díaz, D., Sánchez, A. I., Albarrán, F., Sanz, I., et al. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21186847 · Cited by 14
“[49], and the flow cytometry results were presented following the guidelines of the International Society of Advancement of Cytometry (ISAC) [50].”
MethodMartín‐Cano, F. E., Gaitskell‐Phillips, G., da Silva‐Álvarez, E., Silva‐Rodríguez, A., Castillejo-Rufo, A., Tapia, J. A., Gil, M. C., Ortega‐Ferrusola, C., & Peña, F. J. (2024) · Reproduction · doi:10.1530/rep-23-0067 · Cited by 14
Balatskaya, M. N., Baglay, A. I., Rubtsov, Y. P., & Sharonov, G. V. (2020) · Methods and Protocols · doi:10.3390/mps3020033 · Cited by 12
“Compensation is often used in multi-color flow cytometry, and the relevant details are often discussed in the literature [40].”
BackgroundClick Chemistry for Analysis of Cell Proliferation in Flow Cytometry
Clarke, S. T., Calderon, V., & Bradford, J. A. (2017) · Current Protocols in Cytometry · doi:10.1002/cpcy.24 · Cited by 12
“With multi-parameter testing, single color controls for compensation calculation is necessary and the use of fluorescence-minus-one (FMO) controls is helpful for the setting of markers (Maecker & Trotter, 2006; Roederer, 2001), and is covered in detail in UNIT 10.14 (Roederer, 2002).”
MethodInfluentialSommer, U., Morales, J., Groenewegen, A., Müller, A., Naab, J., Woerly, G., Kamphausen, E., Marsot, H., Bennett, P. K., Kakkanaiah, V. N., et al. (2015) · Bioanalysis · doi:10.4155/bio.15.61 · Cited by 12
Cromvik, J., Johnsson, M., Vaht, K., Johansson, J., & Wennerås, C. (2014) · Immunity Inflammation and Disease · doi:10.1002/iid3.25 · Cited by 12
“Instead of multiple isotype controls, the Fluorescence Minus One (FMO) technique was used [30].”
MethodWoo, H.-K., Kim, C., Choi, Y., Cho, Y. K., Do, L.-N., Kim, H., Jung, D.-H., Allen, M., Jeon, J., Chung, S. H., et al. (2026) · Nature Biomedical Engineering · doi:10.1038/s41551-025-01601-7 · Cited by 11
“Exported data were post-processed to compensate for signal bleed-through between fluorescein isothiocyanate and phycoerythrin channels 57 and remove outliers using the median absolute deviation algorithm 58 with a threshold of 2.5.”
InfluentialA new approach to the study of Hodgkin lymphoma by flow cytometry
Flores, M. B. Á., Corvinos, M. S., Élez, M. M., del Pecho, B. S., Sánchez, L. C., de la Fe, J. G., Santos, R. G., & Valenciano, F. C. (2022) · Pathology · doi:10.1016/j.pathol.2022.07.005 · Cited by 11
Photonic reagents for concentration measurement of flu-orescent proteins with overlapping spectra
Goun, A., Bondar, D. I., Er, A. O., Quine, Z., & RABITZ, H. A. (2016) · Scientific Reports · doi:10.1038/srep25827 · Cited by 11
Lucas, F., Gil‐Pulido, J., LaMacchia, J., Preffer, F., Wallace, P. K., & Lopez, P. (2020) · Cytometry Part A · doi:10.1002/cyto.a.23940 · Cited by 10
“As a result, critical methods of instrument standardization and calibration (27–31), panel and experimental design (32–36), sample preparation and controls (37–39), spillover correction (40), and data presentation and publication (41,42) are emphasized in various seminal publications.”
MethodAdvances in Clinical Mass Cytometry
Koladiya, A., & Davis, K. L. (2023) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2023.05.004 · Cited by 11
Reviving vacuum-dried encapsulated ram spermatozoa via ICSI after 2 years of storage
Palazzese, L., Turri, F., Anzalone, D. A., Saragusty, J., Bonnet, J., Colotte, M., Tuffet, S., Pizzi, F., Luciani, A., Matsukawa, K., et al. (2023) · Frontiers in Veterinary Science · doi:10.3389/fvets.2023.1270266 · Cited by 14
Schmit, T., Klomp, M., & Khan, M. N. (2020) · Methods in molecular biology · doi:10.1007/978-1-0716-1001-5_14 · Cited by 10
Bhowmick, D., van Diepen, F. N. J., Pfauth, A., Tissier, R., & Ratliff, M. (2021) · Scientific Reports · doi:10.1038/s41598-021-99831-7 · Cited by 9
“It has long been established that within different lots, the brightness and emission spectra of Tandem dyes differs [6,7].”
BackgroundSide-by-Side Comparison of Compensation Beads Used in Polychromatic Flow Cytometry
Bhowmick, D., Lowe, S. K., & Ratliff, M. (2023) · ImmunoHorizons · doi:10.4049/immunohorizons.2300066 · Cited by 9
“With improper correction, it is still possible to draw the correct regions/gates if fluorescence minus one controls are used for all fluorochromes (3), but that is not practical to implement.”
BackgroundStandardized flow-cytometry-based protocol to simultaneously measure transcription factor levels
Manso, B. A., & Medina, K. L. (2021) · STAR Protocols · doi:10.1016/j.xpro.2021.100485 · Cited by 9
“Given that transcription factor expression with flow cytometry is often low, proper use of isotype and fluorescence minus one (FMO) controls (Roederer, 2002) during testing is invaluable for determining detection and calls of positivity.”
BackgroundCrawford, L. B. (2022) · Current Protocols · doi:10.1002/cpz1.622 · Cited by 9
Optical sensing and control of T cell signaling pathways
Lee, H. N., Lee, S. E., Inn, K., & Seong, J. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2023.1321996 · Cited by 10
“It heavily relies on fl uorescence analysis, often requiring compensation for signal interference (Roederer, 2002; Szaloki and Goda, 2015; Adan et al., 2017; Staats et al., 2019).”
BackgroundAnyaegbu, C. C., Mao, Y., McGonigle, T., Raja, S., Clarke, T. O., Solomon, T., Black, A. M. B., Fuller, K. A., & Fitzgerald, M. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109223 · Cited by 10
“Fluorescence minus one (FMO) controls (Roederer, 2002) were not used as preliminary cell counts indicated that too few cells would remain available for characterising all cell populations of interest.”
McMenamin, M. B., Lysakova-Devine, T., Wingfield, M. B., O’Herlihy, C., & O’Farrelly, C. (2012) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2012.05.001 · Cited by 9
“To facilitate setting of the electronic gates, fluorescence-minus-one (FMO) controls were used where cells were stained with all but one antibody (Roederer, 2002).”
MethodVisualizing intracellular glycine with two-dye and single-dye ratiometric RNA-based sensors
Bodin, M. R., & Hammond, M. C. (2025) · Nucleic Acids Research · doi:10.1093/nar/gkaf839 · Cited by 9
“Therefore, the TxRed channel represented solely Red Broccoli’s fluorescence, and only a one-way spillover correction was necessary for the determination of FITC channel fluorescence [ 31 ] due solely to Golden Broc-coli.”
InfluentialRaman Flow Cytometry and Its Biomedical Applications
Xu, J., Chen, H., Wang, C., Ma, Y., & Song, Y. (2024) · Biosensors · doi:10.3390/bios14040171 · Cited by 8
“Thirdly, fluorescence labeling can complicate data analysis, particularly when using multiple labels, as the overlap of emission spectra requires complex compensation techniques [17].”
MethodMeeting Measurement Precision Requirements for Effective Engineering of Genetic Regulatory Networks
Beal, J., Teague, B. P., Sexton, J. T., Castillo-Hair, S. M., DeLateur, N. A., Samineni, M., Tabor, J. J., Weiss, R., & the Calibrated Flow Cytometry Study Consortium (2022) · ACS Synthetic Biology · doi:10.1021/acssynbio.1c00488 · Cited by 8
Rare Cells: Focus on Detection and Clinical Relevance
Biasi, S. D., Gibellini, L., Nasi, M., Pinti, M., & Cossarizza, A. (2017) · Series in bioengineering · doi:10.1007/978-981-10-4499-1_2 · Cited by 8
Concomitant Isolation of Primary Astrocytes and Microglia for Protozoa Parasite Infection
Pacheco, A. D. O. L., Amaral, M. P., de Farias, I. S., Bottino, L. Z. M. F., & Bortoluci, K. R. (2020) · Journal of Visualized Experiments · doi:10.3791/60680 · Cited by 8
Hypomorphic mutation in the RAG2 gene affects dendritic cell distribution and migration
Maina, V., Marrella, V., Mantero, S., Cassani, B., Fontana, E., Anselmo, A., Prete, A. D., Sozzani, S., Vezzoni, P., Poliani, P. L., et al. (2013) · Journal of Leukocyte Biology · doi:10.1189/jlb.0713365 · Cited by 8
“correction method was used for all antibodies tested [26].”
MethodPAMPs and DAMPs in Allergy Exacerbation Models
Willart, M. A. M., Pouliot, P., Lambrecht, B. N., & Kool, M. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-496-8_15 · Cited by 7
Introduction to Flow Cytometry
Raveche, E. S., Abbasi, F., Yao, Y., Salerno, E., Kasar, S. N., & Marti, G. E. (2010) · Wiley eBooks · doi:10.1002/9780470910085.ch1 · Cited by 7
Chiang, C., Hu, E. Y., Chang, L., Labanowska, J. M., Zapolnik, K., Mo, X. M., Shi, J., Doong, T.-J., Lozanski, A., Yan, P. S., et al. (2022) · Cell Reports · doi:10.1016/j.celrep.2022.111115 · Cited by 7
Pieper, I. L., Smith, R., Bishop, J., Aldalati, O., Chase, A. J., Morgan, G., & Thornton, C. A. (2017) · Artificial Organs · doi:10.1111/aor.12829 · Cited by 6
“Fluorescence-minusone (FMO) controls (44) were created in parallel”
MethodAn optimized protocol to quantify signaling in human transitional B cells by phospho flow cytometry
Zwang, N. A., Ganesh, B. B., Cardenas, K. T., Chong, A. S., Finn, P. W., & Perkins, D. L. (2018) · Journal of Immunological Methods · doi:10.1016/j.jim.2018.10.002 · Cited by 6
Imaging Flow Cytometry Quantifies Neural Genome Dynamics
Michel, N., Majumdar, U., Lannigan, J. A., & McConnell, M. J. (2019) · Cytometry Part A · doi:10.1002/cyto.a.23783 · Cited by 6
“Single stain controls were used for compensation and gating was determined through unstained and fluorescence minus one controls (FMOs) (22), which are experimental cells stained with all the fluorophores minus the one fluorophore for which positive and negative cutoffs are determined.”
MethodAlgorithms for the selection of fluorescent reporters
Vaidyanathan, P., Appleton, E., Tran, D., Vahid, A., Church, G. M., & Densmore, D. M. (2021) · Communications Biology · doi:10.1038/s42003-020-01599-5 · Cited by 7
Jawbone periosteum‐derived cells with high osteogenic potential controlled by R‐spondin 3
Zhang, S., Zhu, J., Jin, S., Sun, W., Ji, W., & Chen, Z. (2024) · The FASEB Journal · doi:10.1096/fj.202400988rr · Cited by 5
Lost in Translation: Harmonizing Terminology and Defining Mathematical Tools for Panel Optimization
Rajwa, B. P., & Roederer, M. (2025) · Cytometry Part A · doi:10.1002/cyto.a.24972 · Cited by 5
Self-citationEnumerating Hematopoietic Stem and Progenitor Cells in Zebrafish Embryos
Esain, V., Cortes, M., & North, T. E. (2016) · Methods in molecular biology · doi:10.1007/978-1-4939-3771-4_13 · Cited by 5
A Functional Assay to Assess Toxicity During Murine B Cell Development In Vitro
Guilbert, C., Chou, H., Bolt, A. M., Wu, T. H., Luo, V. M., Orthwein, A., & Mann, K. K. (2019) · Current Protocols in Toxicology · doi:10.1002/cptx.91 · Cited by 5
“We also find staining unsorted murine bone marrow samples, either fresh or cryopreserved, useful as gating controls (fluorescence minus one [FMO]; see Current Protocols article: Roederer, 2002; Young, Bolt, Ahn, & Mann, 2016).”
BackgroundMatos, D. M. (2020) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13153 · Cited by 5
Orrù, V., Steri, M., Cucca, F., & Fiorillo, E. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.714461 · Cited by 5
A cross-circulatory platform for monitoring innate allo-responses in lung grafts
Glorion, M., Pascale, F., Estephan, J., Huriet, M., Gouin, C., Urien, C., Blanc, F., Rivière, J., Richard, C., Gelin, V., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0285724 · Cited by 5
Haubruck, P., Colbath, A. C., Blaker, C. L., Clarke, E., Moradi, B., Shu, C. C., & Little, C. B. (2026) · Scientific Reports · doi:10.1038/s41598-026-40338-4 · Cited by 4
“…overlap on the multi-colour flow cytometer were set using the AbC Total Antibody Compensation Kit (Thermo Fischer), isotype control antibodies were used during optimization of the experiments to assess any non-specific binding, and “fluorescent minus one” were used to set initial gates 36 .”
Zhou, Q., Song, J.-L., Wu, X., Ke, Q., Hu, L.-L., Ma, X.-Y., Zhou, J.-M., Zhu, J.-J., Aimaiti, M., Huang, R.-T., et al. (2026) · LabMed discovery. · doi:10.1016/j.lmd.2026.100116 · Cited by 5
Multiplexed cytometry for single cell chemical biology
Schares, H. A. M., Hayes, M., Balsamo, J. A., Thirman, H. L., Bachmann, B. O., & Irish, J. M. (2023) · Methods in cell biology · doi:10.1016/bs.mcb.2023.03.007 · Cited by 4
Comparison of Deep-Learning Models for Classification of Cellular Phenotype From Flow Cytometry Data
Mashford, B. S., Hewitt, T., May, M., Chuah, A., & Andrews, T. D. (2025) · IEEE Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbbio.2025.3562597 · Cited by 4
Reducing Spreading: Removing the Impact of Irrelevant Dyes Improves Unmixed Flow Cytometry Data
Kmet, R., & Novo, D. J. (2025) · Cytometry Part A · doi:10.1002/cyto.a.24957 · Cited by 4
Kaposi, A., Toldi, G., Meszaros, G., Szalay, B., Veress, G., & Vásárhelyi, B. (2012) · InTech eBooks · doi:10.5772/38513 · Cited by 5
“, the amount of fluorescence has to reflect a biochemical quantity), samples stained with a single dye should be included for use in setting fluorescence compensation (Roederer, 2002).”
BackgroundFlow Cytometry and Immunophenotyping in Drug Development
Papenfuss, T. L. (2017) · Molecular and integrative toxicology · doi:10.1007/978-3-319-47377-2_6 · Cited by 5
Eberhardt, N., Sanmarco, L. M., & Aoki, M. P. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9148-8_28 · Cited by 5
B-Cell Commitment to IL-10 Production: The VertX Il10egfp Mouse
Oka, A., Liu, B., Herzog, J., & Sartor, R. B. (2021) · Methods in molecular biology · doi:10.1007/978-1-0716-1237-8_19 · Cited by 4
Flow Cytometry Analysis of Cell-Surface Markers to Identify Human Naïve Pluripotent Stem Cells
Rugg‐Gunn, P. J. (2021) · Methods in molecular biology · doi:10.1007/978-1-0716-1908-7_16 · Cited by 4
Coupled Tensor Factorization for Flow Cytometry Data Analysis
Flores, P., Harlé, G., Notarantonio, A., Usevich, K., D’Aveni, M., Grandemange, S., Rubio, M., & Brie, D. (2022) · Machine learning for signal processing ... · doi:10.1109/mlsp55214.2022.9943436 · Cited by 4
“To validate our method, CTFlowHD is applied to FCM controlled data sets after compensation [10] and a non-linear transformation [11].”
MethodGlorion, M., Pascale, F., Huriet, M., Estephan, J., Gouin, C., Urien, C., Bourge, M., Egidy, G., Richard, C., Gelin, V., et al. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1281546 · Cited by 4
Data-Driven Compensation for Flow Cytometry of Solid Tissues
van Rodijnen, N., Pieters, M. H. E. C., Hoop, S., & Nap, M. (2011) · Advances in Bioinformatics · doi:10.1155/2011/184731 · Cited by 4
“This percentage is based on the correlation coefficient between the fluorochrome intensity of a SSC in the primary and secondary detector(s) [1, 3].”
BackgroundMethodPrimary and Secondary Antibodies and Flow Cytometry Controls
Hammerbeck, C. D., Goetz, C. A., & Bonnevier, J. L. (2018) · Techniques in life science and biomedicine for the non-expert · doi:10.1007/978-3-319-98071-3_6 · Cited by 4
Anthrax Toxin as a Molecular Platform to Target Nociceptive Neurons and Modulate PainPreprint
Yang, N. J., Isensee, J., Neel, D. V., Liu, S. M., Zhang, H. X. B., Belu, A., Palan, S., Kennedy-Curran, A., Röderer, P., Nitzsche, A., et al. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.03.28.004150 · Cited by 4
Sample multiplexing in CyTOF: Path to optimize single-cell proteomic profiling
Müftüoğlu, M., & Andreeff, M. (2024) · Cell Signaling · doi:10.46439/signaling.2.041 · Cited by 3
“Flow cytometry often suffers from signal spillover between barcoding and analyte-specific channels, necessitating meticulous panel design and sometimes leading to the exclusion of certain fluorophores, which compromises the simultaneous assessment of multiple analytes [35,36].”
Immunophenotyping of Tissue Samples Using Multicolor Flow Cytometry
Sykora, M. M., & Reschke, M. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9145-7_16 · Cited by 4
High-throughput single cell data analysis – A tutorial
Tinnevelt, G. H., Wouters, K., Postma, G., Folcarelli, R., & Jansen, J. J. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338872 · Cited by 4
Isolation of macrophages from mouse skin wounds for single-cell RNA sequencing
Willenborg, S., Roscito, J. G., Gerbaulet, A., Roers, A., Dahl, A., Eming, S. A., & Reinhardt, S. (2022) · STAR Protocols · doi:10.1016/j.xpro.2022.101337 · Cited by 3
“, prepare a set of control stainings with leaving out each antibody once) (Herzenberg et al., 2006; Roederer 2002).”
BackgroundAnalyzing the Tumor-Immune Microenvironment by Flow Cytometry
Santinon, F., Young, Y. K., Rincon, S. V. D., & Mann, K. K. (2023) · Methods in molecular biology · doi:10.1007/978-1-0716-2914-7_2 · Cited by 3
Sara, W., Maria, V., Barbara, G., Anaïs, V., Keuters, M. H., Salli, A., Kari, A., Koıstınaho, J., & Noè, F. M. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/821645 · Cited by 3
Andersen, M. N., Skovbo, A., Petersen, C. C., & Hokland, M. (2020) · Cytometry Part A · doi:10.1002/cyto.a.24013 · Cited by 2
“This is of special importance for multi-color panels including tandem fluorochromes (6).”
BackgroundSelective vulnerability of human synapses to soluble tau oligomers
Kadamangudi, S., Sánchez-Sánchez, L., Kayed, R., Limón, A., & Taglialatela, G. (2026) · Journal of Alzheimer s Disease · doi:10.1177/13872877261416539 · Cited by 2
Transcription Factor Evaluation by Flow Cytometry
Fenoglio, D., & Altosole, T. (2021) · Methods in molecular biology · doi:10.1007/978-1-0716-1311-5_3 · Cited by 2
Mutavhatsindi, H., & Riou, C. (2022) · STAR Protocols · doi:10.1016/j.xpro.2022.101771 · Cited by 2
“Note: To aid with the discrimination of positive events, one can set up fluorescent minus one (FMO) controls, where the marker of interest is omitted from the staining mix (Roederer, 2002).”
Mesocosm evidence for sandprawn-mediated shifts in pelagic resource ratios and phytoplankton traits
de Cerff, C., Rocke, E., Oyatoye, A. E., Maniel, G., & Pillay, D. (2024) · Estuarine Coastal and Shelf Science · doi:10.1016/j.ecss.2024.108874 · Cited by 2
Single-cell RNA flow cytometry to assess intratumoral production of cytokines/chemokines
Lam, K. C., & Goldszmid, R. S. (2024) · Methods in cell biology · doi:10.1016/bs.mcb.2024.10.013 · Cited by 2
Morales, M., Zhang, F., & Xiang, Y. (2024) · Methods in molecular biology · doi:10.1007/978-1-0716-4160-6_14 · Cited by 2
Measuring T Cell Function in Innate Immune Models
Barker, B. R. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-481-4_10 · Cited by 2
Rajwa, B. P. (2011) · Cytometry Part A · doi:10.1002/cyto.a.21118 · Cited by 2
“Putting aside the practical difficulty of preparing such a set of controls [which has been addressed in detail in the letter by Roederer (9)], in the general case this may lead to a model with an underdetermined system of equations that do not allow for a unique solution, although if some constraints are imposed one m…”
BackgroundInfluentialBurton, O. T., Bücken, L., Vuyst, L. D., Humblet‐Baron, S., Leon, A. L. M. D., Khan, S., Cerveira, J., Dooley, J., & Liston, A. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.10.27.684855 · Cited by 2
Porphyrin-Modified Beads for Use as Compensation Controls in Flow Cytometry
Bauta, W. E., Grayson, M. H., Titone, R., Rebeles, J., & Rebel, V. I. (2023) · Journal of Visualized Experiments · doi:10.3791/65294 · Cited by 1
Anselmo, A., & Boselli, D. (2023) · Methods in molecular biology · doi:10.1007/978-1-0716-3366-3_6 · Cited by 1
Complete CD16A Deficiency and Defective NK Cell Function in a Man Living with HIV
Zhang, W., Scott, A. F., Mohr, D. W., Ingersoll, R., Shoucair, P. E. J., Bream, J. H., Nilles, T. L., Zhang, H., Chen, Y., Mailliard, R. B., et al. (2025) · Journal of Clinical Immunology · doi:10.1007/s10875-025-01886-y · Cited by 2
“Gates were set using fluorescence-minus-one controls [24 ].”
InfluentialHumoral and Cellular Immune Responses to SARS-CoV-2 in Participants with Head and Neck Cancer
Marutescu, L. G., Enea, A. G., Antoniadis, N.-M., Neculae, M., Costea, D.-A., Popa, M., Dragu, E., Codrici, E., Ristoiu, V., Gălățeanu, B., et al. (2025) · Viruses · doi:10.3390/v17060848 · Cited by 1
Preconditioning donors with corticosteroids improves early lung graft immunity
Schwartz-Cornil, I., Pascale, F., Jouneau, L., Huriet, M., Estephan, J., Bourge, M., Richard, C., Gelin, V., Bevilacqua, C., Rivière, J., et al. (2025) · Frontiers in Immunology · doi:10.3389/fimmu.2025.1668591 · Cited by 1
Bonavita, O., Massara, M., Anselmo, A., Somma, P., Brühl, H., Mack, M., Locati, M., & Bonecchi, R. (2015) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/bs.mie.2015.09.011 · Cited by 1
Metadata
- Authors
- Roederer, M.
- Affiliations
- National Institutes of Health (US)
- Corresponding author
- Roederer, Mario
- ORCID
- Roederer, Mario
- Venue
- Current Protocols in Cytometry
- Publisher
- Wiley
- Published
- 2002-10
- Volume
- 22
- Issue
- 1
- Pages
- Unit 1.14-Unit 1.14
- ISSN
- 1934-9297 (ISSN-L)
- 1934-9300
- OpenAlex
- W1951089650
- Cited by
- 228
- References
- 6
- Citations by year
- 2026: 7 · 2025: 15 · 2024: 13 · 2023: 14 · 2022: 19 · 2021: 19 · 2020: 30 · 2019: 15 · 2018: 8 · 2017: 14 · 2016: 12 · 2015: 11 · 2014: 8 · 2013: 18 · 2012: 4
- FWCI
- 0.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Current Protocols in Cytometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- compensation, multiparameter flow cytometry, software compensation, compensation control, data visualization
- MeSH terms
- Flow Cytometry, Fluorescent Dyes, Leukocytes, Mononuclear, Microspheres, Phycoerythrin, Fluorescein-5-isothiocyanate, Fluorescence Resonance Energy Transfer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.