Compensation in Flow Cytometry
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Many people using multi‐color flow cytometry do not understand what compensation is, when it is needed, or how it should be applied. The author provides a clear explanation of the nature of compensation, the factors that affect compensation values, and the effect of compensation on data visualization. Both hardware and software compensation are covered. Although the subject is treated from a mathematical perspective, the manner of presentation is very straightforward. The unit discusses appropriate controls and protocols to check compensation settings, as well as introducing the concept of fluorescence‐minus‐one gates. Many example figures are supplied to give the reader a clear indication of how the author believes compensation should be handled. Keywords: flow cytometry; spectral compensation; fluorescence spillover; autofluorescence; fluorescence minus one
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is not possible to interpret data from multiparameter flow cytometry without including these essential controls [6].”
From Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition) (2021) · cites this paper as [6]
Citations
Cites
Spectral compensation for flow cytometry: Visualization artifacts, limitations, and caveats
Roederer, M. (2001) · Cytometry · doi:10.1002/1097-0320(20011101)45:3<194::aid-cyto1163>3.0.co;2-c · Cited by 558 · cited 2×
“While there are small errors in the electronics that can contribute to this spread, the most significant source of error is photon-counting statistics (Roederer, 2001).”
BackgroundSelf-citationTwo-color immunofluorescence using a fluorescence-activated cell sorter.
Loken, M. R., Parks, D. R., & Herzenberg, L. A. (1977) · Journal of Histochemistry & Cytochemistry · doi:10.1177/25.7.330738 · Cited by 193
Fluorescence Spectral Overlap Compensation for Any Number of Flow Cytometry Parameters
Bagwell, C. B., & Adams, E. G. (1993) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1993.tb38775.x · Cited by 157 · cited 1×
“This topic is dealt with in detail by Bagwell and Adams (1993).”
BackgroundHandbook of Experimental Immunology
Mellors, R. C. (1969) · American Journal of Clinical Pathology · doi:10.1093/ajcp/51.5.657 · Cited by 105
A single laser method for subtraction of cell autofluorescence in flow cytometry
Alberti, S., Parks, D. R., & Herzenberg, L. A. (1987) · Cytometry · doi:10.1002/cyto.990080203 · Cited by 98
Roederer, M., & Murphy, R. F. (1986) · Cytometry · doi:10.1002/cyto.990070610 · Cited by 95 · cited 1×
“Autofluorescence compensation is more fully described in published references by Roederer and Murphy (1986) and Alberti et al. (1987).”
BackgroundSelf-citation
Cited by
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols
on behalf of the EuroFlow Consortium (EU-FP6, L.-C.-2.-0., Kalina, T., Flores-Montero, J., van der Velden, V. H. J., Martin-Ayuso, M., Böttcher, S., Ritgen, M., Almeida, J., Lhermitte, L., Asnafi, V, et al. (2012) · Leukemia · doi:10.1038/leu.2012.122 · Cited by 783
Guidelines for the use of flow cytometry and cell sorting in immunological studies *
Cossarizza, A., Chang, H., Radbruch, A., Akdis, M., Andrä, I., Annunziato, F., Bacher, P., Barnaba, V., Battistini, L., Bauer, W. M., et al. (2017) · European Journal of Immunology · doi:10.1002/eji.201646632 · Cited by 542
Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition)
Cossarizza, A., Chang, H., Radbruch, A., Abrignani, S., Addo, R., Akdis, M., Andrä, I., Andreata, F., Annunziato, F., Arranz, E., et al. (2021) · European Journal of Immunology · doi:10.1002/eji.202170126 · Cited by 531
Gerner, M. Y., Kastenmuller, W., Ifrim, I., Kabat, J., & Germain, R. N. (2012) · Immunity · doi:10.1016/j.immuni.2012.07.011 · Cited by 425
“We mathematically apply simple compensation correction algorithms to every imaged voxel after data acquisition in a manner akin to flow cytometry (Roederer, 2002), which results in robust removal of the spillover signal (Fig.”
MethodInfluentialAutissier, P., Soulas, C., Burdo, T. H., & Williams, K. C. (2010) · Cytometry Part A · doi:10.1002/cyto.a.20859 · Cited by 236
“Gating controls were determined using fluorescence minus one (FMO) controls for CD1c, CD14, CD16 where all antibodies are used except one (22,23) (Supporting Information Figs.”
MethodGut Dysbiosis Promotes Preeclampsia by Regulating Macrophages and Trophoblasts
Jin, J., Gao, L., Zou, X., Zhang, Y., Zheng, Z., Zhang, X., Li, J., Tian, Z., Wang, X., Gu, J., et al. (2022) · Circulation Research · doi:10.1161/circresaha.122.320771 · Cited by 187
Detection of Intracellular Cytokines by Flow Cytometry
Yin, Y., Mitson‐Salazar, A., & Prussin, C. (2015) · Current Protocols in Immunology · doi:10.1002/0471142735.im0624s110 · Cited by 162
“Every sample should be analyzed with both a specifically stained tube (i.e., anti-cytokine MAbs) and a control tube (e.g., isotype-matched or fluorescence minus one control; Roederer, 2002).”
BackgroundIL-4 induces M2 macrophages to produce sustained analgesia via opioids
Celik, M. Ö., Łabuz, D., Keye, J., Glauben, R., & Machelska, H. (2020) · JCI Insight · doi:10.1172/jci.insight.133093 · Cited by 163
“solutions according to the manufacturer’s recommendations before the flow cytometer analysis (66, 67).”
MethodEscribano, L., Diaz‐Agustin, B., López, A., Núñez López, R., García‐Montero, A., Almeida, J., Prados, A., Angulo, M., Herrero, S., Orfao, A., et al. (2004) · Cytometry Part B: Clinical Cytometry · doi:10.1002/cyto.b.10072 · Cited by 147
“immunophenotypic analysis of other nucleated blood cells (21).”
BackgroundHIV persists in CCR6+CD4+ T cells from colon and blood during antiretroviral therapy
Gosselin, A., Wiche Salinas, T. R., Planas, D., Wacleche, V. S., Zhang, Y., Fromentin, R., Chomont, N., Cohen, É. A., Shacklett, B., Mehraj, V., et al. (2017) · AIDS · doi:10.1097/qad.0000000000001309 · Cited by 137
“The sorting gates were set using fluorescence minus one controls [41,69].”
BackgroundMethodMacrophages Maintain Epithelium Integrity by Limiting Fungal Product Absorption
Chikina, A. S., Nadalin, F., Maurin, M., San-Roman, M., Thomas-Bonafos, T., Li, X. V., Lameiras, S., Baulande, S., Henri, S., Malissen, B., et al. (2020) · Cell · doi:10.1016/j.cell.2020.08.048 · Cited by 138
Adoptive transfer of M2 macrophages reduces neuropathic pain via opioid peptides
Pannell, M., Łabuz, D., Celik, M. Ö., Keye, J., Batra, A., Siegmund, B., & Machelska, H. (2016) · Journal of Neuroinflammation · doi:10.1186/s12974-016-0735-z · Cited by 141
“The staining specificity of antibodies was tested by using fluorescence minus one (FMO) controls [38].”
Lo Celso, C., Lin, C. P., & Scadden, D. T. (2011) · Nature Protocols · doi:10.1038/nprot.2010.168 · Cited by 115
Standard methods for Apis mellifera honey research
de Almeida‐Muradian, L. B., Barth, O. M., Dietemann, V., Eyer, M., de Freitas, A. D. S., Martel, A., Marcazzan, G. L., Marchese, C. M., Mucignat‐Caretta, C., Pascual‐Maté, A., et al. (2020) · Journal of Apicultural Research · doi:10.1080/00218839.2020.1738135 · Cited by 119
O’Neill, K., Aghaeepour, N., Špidlen, J., & Brinkman, R. R. (2013) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003365 · Cited by 106
“The total signal to remove from each channel can be computed by solving a system of linear equations based on this data to produce a spillover matrix, which when inverted and multiplied with the raw data from the cytometer produces the compensated data [12,13].”
BackgroundMethodIsensee, J., Krahé, L., Moeller, K., Pereira, V., Sexton, J. E., Sun, X., Emery, E. C., Wood, J. N., & Hucho, T. B. (2017) · Science Signaling · doi:10.1126/scisignal.aah4874 · Cited by 102
“Raw fluorescence data of the controls were used to calculate the slope of best-fit straight lines by linear regression, which was then used to compensate for spillover, as described previously (47).”
MethodHIV-1 selectively targets gut-homing CCR6+CD4+ T cells via mTOR-dependent mechanisms
Planas, D., Zhang, Y., Monteiro, P., Goulet, J.-P., Gosselin, A., Grandvaux, N., Hope, T. J., Fassati, A., Routy, J., & Ancuța, P. (2017) · JCI Insight · doi:10.1172/jci.insight.93230 · Cited by 105
“Flow cytometry gates were defined using the fluorescence minus one strategy (16, 91).”
MethodThe evolution of spectral flow cytometry
Nolan, J. P. (2022) · Cytometry Part A · doi:10.1002/cyto.a.24566 · Cited by 97
“expansion in the number of different fluorescent conjugates for antibody labeling and software tools to facilitate data analysis [23, 24], characterized so-called polychromatic flow cytometry [25].”
MethodMass cytometry panel optimization through the designed distribution of signal interference
Takahashi, C., Au‐Yeung, A., Fuh, F. K., Ramirez‐Montagut, T., Bolen, C., Mathews, W. R., & O’Gorman, W. E. (2016) · Cytometry Part A · doi:10.1002/cyto.a.22977 · Cited by 88
“In 2002, Roederer introduced the concept of the fluorescence-minus-one (FMO) control as a method to properly define thresholds for gate boundaries in flow cytometry data (17).”
BackgroundMethodPKA-RII subunit phosphorylation precedes activation by cAMP and regulates activity termination
Isensee, J., Kaufholz, M., Knape, M. J., Hasenauer, J., Hammerich, H., Gonczarowska-Jorge, H., Zahedi, R. P., Schwede, F., Herberg, F. W., & Hucho, T. B. (2018) · The Journal of Cell Biology · doi:10.1083/jcb.201708053 · Cited by 92
“Raw fluorescence data of the controls were used to calculate the slope of best fit straight lines by linear regression, which was then used to compensate spill-over as described previously (Roederer, 2002).”
MethodFlow Cytometry: A Blessing and a Curse
Drescher, H. K., Weiskirchen, S., & Weiskirchen, R. (2021) · Biomedicines · doi:10.3390/biomedicines9111613 · Cited by 83
“FITC and PE overlapping signals that are not detected in either of the channels can be ignored [25].”
BackgroundLymph nodes as barriers to T‐cell rejuvenation in aging mice and nonhuman primates
Thompson, H. L., Smithey, M. J., Uhrlaub, J. L., Jeftić, I., Jergović, M., White, S. E., Currier, N., Lang, A. M., Okoye, A., Park, B., et al. (2019) · Aging Cell · doi:10.1111/acel.12865 · Cited by 75
“Optimization procedures for flow cytometry are based on current standards and include full‐minus‐one (FMO) gating controls (Roederer, 2002).”
MethodPrietl, B., Treiber, G. M., Mader, J. K., Höller, E., Wolf, M., Pilz, S., Graninger, W. B., Obermayer-Pietsch, B. M., & Pieber, T. R. (2013) · European Journal of Nutrition · doi:10.1007/s00394-013-0579-6 · Cited by 84
“isotype controls and the fluorochrome minus one (FMO) method [25] were used to avoid measuring unspecific binding signals and to obtain a more precise definition for cells having fluorescence above the background level.”
MethodNovo, D. J., Grégori, G., & Rajwa, B. P. (2013) · Cytometry Part A · doi:10.1002/cyto.a.22272 · Cited by 79
“This process leading to the recovery of abundances is known as FC compensation and is described extensively in the FC literature (7,8).”
MethodCarlson, L.-M., Rasmuson, A., Idborg, H., Segerström, L., Jakobsson, P., Sveinbjørnsson, B., & Kogner, P. (2013) · Carcinogenesis · doi:10.1093/carcin/bgt009 · Cited by 77
Tighe, R. M., Redente, E. F., Yu, Y.-R. A., Herold, S., Sperling, A. I., Curtis, J. L., Duggan, R., Swaminathan, S., Nakano, H., Zacharias, W. J., et al. (2019) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2019-0191st · Cited by 74
“However, in reality, compensation is a simple and logical procedure, and a variety of detailed step-by-step guides are available (28, 29); for new and less-experienced investigators it produces better and more reproducible results.”
BackgroundMackroth, M. S., Malhotra, I. J., Mungai, P., Koech, D., Muchiri, E. M., & King, C. L. (2011) · The Journal of Immunology · doi:10.4049/jimmunol.1001188 · Cited by 73
“It is a staining control that employs all reagents used in a flow cytometry assay except for one fluorochrome of interest (termed FMO) to control for the contribution of spectral overlap to the background when using multiple fluorochromes (43, 44).”
MethodSelective targeting of NaV1.7 via inhibition of the CRMP2-Ubc9 interaction reduces pain in rodents
Cai, S., Moutal, A., Yu, J., Chew, L. A., Isensee, J., Chawla, R., Gómez, K., Luo, S., Zhou, Y., Chefdeville, A., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abh1314 · Cited by 66
Autissier, P., Soulas, C., Burdo, T. H., & Williams, K. C. (2010) · Journal of Immunological Methods · doi:10.1016/j.jim.2010.06.017 · Cited by 66
“Further gating adjustments were made based on fluorescence minus one (FMO) where all antibodies were present except the one of interest as previously described (Roederer, 2002; Autissier et al., 2010).”
MethodAtehortúa, L., Rojas, M., Vásquez, G. M., Muñoz‐Vahos, C. H., Vanegas-García, A. L., Posada‐Duque, R., & Castaño, D. (2019) · Arthritis Research & Therapy · doi:10.1186/s13075-018-1796-4 · Cited by 67
“Ashland, OR, USA) software; the fluorescence minus one method was performed for each antibody to determine the positive and negative events [35].”
MethodVenning, F. A., Zornhagen, K. W., Wullkopf, L., Sjölund, J., Rodriguez-Cupello, C., Kjellman, P., Morsing, M., Hajkarim, M. C., Won, K., Erler, J. T., et al. (2021) · Journal of Experimental & Clinical Cancer Research · doi:10.1186/s13046-021-01944-4 · Cited by 66
“Fluorescent minus one (FMO) controls were used for each fluorophore to help guide proper gating on each marker [24] (see Suppl.”
MethodEvaluating spectral cytometry for immune profiling in viral disease
Niewold, P., Ashhurst, T. M., Smith, A. L., & King, N. J. C. (2020) · Cytometry Part A · doi:10.1002/cyto.a.24211 · Cited by 68
Separating Stem Cells by Flow Cytometry: Reducing Variability for Solid Tissues
Alexander, C. M., Puchalski, J. R., Klos, K. S., Badders, N. M., Ailles, L., Kim, C. F., Dirks, P. B., & Smalley, M. J. (2009) · Cell stem cell · doi:10.1016/j.stem.2009.11.008 · Cited by 70
“For the ability to reproduce functional data from live cell sorts, machine factors December 4, 2009 ª2009 Elsevier Inc. 579 that can affect sample recovery, viability, and function, such as nozzle tip diameter, sheath pressure and fluid composition should be reported (see examples in figures in the Supplemental Data).”
BackgroundMethodInfluentialAcute Malaria Induces PD1+CTLA4+ Effector T Cells with Cell-Extrinsic Suppressor Function
Mackroth, M. S., Abel, A., Steeg, C., Wiesch, J. S. Z., & Jacobs, T. (2016) · PLoS Pathogens · doi:10.1371/journal.ppat.1005909 · Cited by 68
Live cell microscopy: From image to insight
Cuny, A. P., Schlottmann, F. P., Ewald, J. C., Pelet, S. B., & Schmoller, K. M. (2022) · Biophysics Reviews · doi:10.1063/5.0082799 · Cited by 66
Biological surface properties in extracellular vesicles and their effect on cargo proteins
Santucci, L., Bruschi, M., Zotto, G. D., Antonini, F., Ghiggeri, G. M., Panfoli, I., & Candiano, G. (2019) · Scientific Reports · doi:10.1038/s41598-019-47598-3 · Cited by 65
Russell, K. C., Tucker, H. A., Bunnell, B. A., Andreeff, M., Schober, W., Gaynor, A. S., Strickler, K. L., Lin, S., Lacey, M. R., & O'Connor, K. C. (2013) · Tissue Engineering Part A · doi:10.1089/ten.tea.2012.0649 · Cited by 56
“Spectral overlap was corrected with multicolor compensation as previously described.(28) Samples were analyzed and sorted by gating on live cells by forward and side scatter.”
MethodFluorochrome choices for multi-color flow cytometry
Flores-Montero, J. A., Kalina, T., Corral-Mateos, A., Sanoja-Flores, L., Pérez‐Andrés, M., Martin-Ayuso, M., Sędek, Ł., Rejlová, K., Mayado, A., Fernandez, P. C., et al. (2019) · Journal of Immunological Methods · doi:10.1016/j.jim.2019.06.009 · Cited by 56
Single-Cell Approaches to Profile the Response to Immune Checkpoint Inhibitors
Gibellini, L., Biasi, S. D., Porta, C., Tartaro, D. L., Depenni, R., Pellacani, G., Sabbatini, R., & Cossarizza, A. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.00490 · Cited by 56
Basics of standardization and calibration in cytometry – a review
Mittag, A., & Tárnok, A. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910033 · Cited by 53
Loos, C., Moeller, K., Fröhlich, F., Hucho, T. B., & Hasenauer, J. (2018) · Cell Systems · doi:10.1016/j.cels.2018.04.008 · Cited by 59
“The slope of best fit straight lines were determined by linear regression and used to compensate bleed through as described previously (Roederer, 2002).”
MethodIntroduction to flow cytometry
Marti, G. E., Stetler‐Stevenson, M., Bleesing, J., & Fleisher, T. A. (2001) · Seminars in Hematology · doi:10.1016/s0037-1963(01)90043-5 · Cited by 54
Bernier, A., Cleret‐Buhot, A., Zhang, Y., Goulet, J.-P., Monteiro, P., Gosselin, A., DaFonseca, S., Wacleche, V. S., Jenabian, M.-A., Routy, J., et al. (2013) · Retrovirology · doi:10.1186/1742-4690-10-160 · Cited by 56
“Positivity gates were placed using fluorescence minus one (FMO), as previously described [124].”
MethodPain modulators regulate the dynamics of PKA-RII phosphorylation in subgroups of sensory neurons
Isensee, J., Diskar, M., Waldherr, S., Buschow, R., Hasenauer, J., Prinz, A., Allgöwer, F., Herberg, F. W., & Hucho, T. B. (2013) · Journal of Cell Science · doi:10.1242/jcs.136580 · Cited by 58
“Bleed-through was compensated as described previously (Roederer, 2002).”
Standard methods forApis melliferavenom research
de Graaf, D. C., Brochetto-Braga, M. R., de Abreu, R. M. M., Blank, S., Bridts, C. H., Clerck, L. S. D., Devreese, B. V., Ebo, D. G., Ferris, T. J., Hagendorens, M. M., et al. (2020) · Journal of Apicultural Research · doi:10.1080/00218839.2020.1801073 · Cited by 50
“This can be done by using different dilutions of the antibody and, using the correct flow cytometric settings, looking for the most optimal resolution in comparison with an FMO (Fluorescence Minus One) measurement as a control (Roederer, 2002).”
MethodInfluentialDauby, N., Kummert, C., Lecomte, S., Liesnard, C., Delforge, M., Donner, C., & Marchant, A. (2014) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiu255 · Cited by 49
“cells within the different subsets [28].”
Compensation in multicolor flow cytometry
Szalóki, G., & Goda, K. (2015) · Cytometry Part A · doi:10.1002/cyto.a.22736 · Cited by 49
Oncostatin M induces hyperalgesic priming and amplifies signaling of cAMP to ERK by RapGEF2 and PKA
Carbajal, A. G., Ebersberger, A., Thiel, A., Ferrari, L. F., Acuna, J., Brosig, S., Isensee, J., Moeller, K., Siobal, M., Rose‐John, S., et al. (2020) · Journal of Neurochemistry · doi:10.1111/jnc.15172 · Cited by 46
“The slope of best linear fit was determined by linear regression and used to compensate spill-over as described (Roederer, 2002).”
MethodDepolarization induces nociceptor sensitization by CaV1.2-mediated PKA-II activation
Isensee, J., van Cann, M., Despang, P., Araldi, D., Moeller, K., Petersen, J., Schmidtko, A., Matthes, J., Levine, J. D., & Hucho, T. B. (2021) · The Journal of Cell Biology · doi:10.1083/jcb.202002083 · Cited by 48
DaFonseca, S., Niessl, J., Pouvreau, S., Wacleche, V. S., Gosselin, A., Cleret‐Buhot, A., Bernard, N. F., Tremblay, C. L., Jenabian, M.-A., Routy, J., et al. (2015) · Retrovirology · doi:10.1186/s12977-015-0164-6 · Cited by 52
“The sorting gates were set as depicted in Additional file 2: Figure S2 using the FMOs controls, as previously described [21,101].”
MethodSarikonda, G., Pahuja, A., Kalfoglou, C., Burns, K., Nguyen, K., Ch’en, I. L., Pollner, R., Tangri, S., & Dakappagari, N. K. (2020) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.21891 · Cited by 45
“As a generally accepted principle (Roederer, 2002), 0.”
BackgroundInfluentialPetit, V., Massonnet, G., Maciorowski, Z., Touhami, J., Thuleau, A., Némati, F., Laval, J., Château‐Joubert, S., Servely, J., Vallerand, D., et al. (2013) · Laboratory Investigation · doi:10.1038/labinvest.2013.44 · Cited by 45
Cattin, A., Salinas, T. R. W., Gosselin, A., Planas, D., Shacklett, B. L., Cohen, É. A., Ghali, M. P., Routy, J., & Ancuța, P. (2019) · AIDS · doi:10.1097/qad.0000000000002195 · Cited by 53
Analyzing the Tumor Microenvironment by Flow Cytometry
Young, Y. K., Bolt, A. M., Ahn, R., & Mann, K. K. (2016) · Methods in molecular biology · doi:10.1007/978-1-4939-3801-8_8 · Cited by 42
Immune Cell Phenotyping Using Flow Cytometry
Pockley, A. G., Foulds, G. A., Oughton, J. A., Kerkvliet, N. I., & Multhoff, G. (2015) · Current Protocols in Toxicology · doi:10.1002/0471140856.tx1808s66 · Cited by 40
“…essential to understand the principles of compensation, (in-depth discussions on compensation can be found in a number of resources; Roederer, 2000; Roederer, 2002; Roederer, 2011; Nguyen et al., 2013) the only approach for effectively compensating samples is to use automatic compensation…”
BackgroundBrussel, I. V., Vré, E. A. V., Meyer, G. R. Y. D., Vrints, C. J., Bosmans, J. M., & Bult, H. (2011) · Clinical Science · doi:10.1042/cs20100440 · Cited by 45
High‐Sensitivity Detection of PNH Red Blood Cells, Red Cell Precursors, and White Blood Cells
Sutherland, D. R., Illingworth, A. J., Keeney, M., & Richards, S. J. (2015) · Current Protocols in Cytometry · doi:10.1002/0471142956.cy0637s72 · Cited by 38
“…Metal or hard plastic test tube rack for racking samples (see step 10) before acquisition Flow cytometer able to detect emissions from FITC and PE, appropriately compensated (see UNIT 1.14; Roederer, 2002) Phenotypic Analysis 6.37.3 Current Protocols in Cytometry Supplement 72 Prepare sample 1.”
MethodInfluentialvan Cann, M., Kuzmenkov, A. I., Isensee, J., Andreev-Andrievskiy, A. A., Peigneur, S., Khusainov, G., Berkut, A. A., Tytgat, J., Vassilevski, A. A., & Hucho, T. B. (2020) · FEBS Journal · doi:10.1111/febs.15593 · Cited by 38
High‐Dimensional Fluorescence Cytometry
Ashhurst, T. M., Smith, A. L., & King, N. J. C. (2017) · Current Protocols in Immunology · doi:10.1002/cpim.37 · Cited by 38
Perfetto, S. P., Chattopadhyay, P. K., Wood, J. C. S., Nguyen, R., Ambrozak, D. R., Hill, J. P., & Roederer, M. (2014) · Cytometry Part A · doi:10.1002/cyto.a.22579 · Cited by 36
“SIps5MFIðmAbÞ ffiffiffiffi Q p =ðBCAL1BSOSÞ (3)”
BackgroundSelf-citationKling, H. M., & Norris, K. A. (2016) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiw032 · Cited by 35
“An ELISpot assay was used for detection of cells secreting anti-KEX1 antibody, to determine the presence of KEX1-specific memory B cells, according to previously described methods (Supplementary Materials) [22].”
BackgroundInfluentialConacher, C. G., Naidoo-Blassoples, R. K., Rossouw, D., & Bauer, F. F. (2020) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-020-10607-x · Cited by 35
“This is an essential step in multicolour flow cytometric analyses as it removes the signal of a target fluorochrome from all detectors except the specific detector measuring that fluorochrome (Roederer 2002).”
BackgroundDong, M. B., Rahman, M. J., & Tarbell, K. V. (2015) · Journal of Immunological Methods · doi:10.1016/j.jim.2015.08.015 · Cited by 37
“FMO controls are samples that include all fluorophores, except the color being analyzed, and have been validated as an optimal negative control (Roederer, 2002).”
BackgroundWacleche, V. S., Cattin, A., Goulet, J.-P., Gauchat, D., Gosselin, A., Cleret‐Buhot, A., Zhang, Y., Tremblay, C. L., Routy, J., & Ancuța, P. (2018) · Blood Advances · doi:10.1182/bloodadvances.2018020123 · Cited by 36
Lopez, E. R., Carbajal, A. G., Tian, J., Bavencoffe, A. G., Zhu, M. X., DESSAUER, C. W., & Walters, E. T. (2020) · Neuropharmacology · doi:10.1016/j.neuropharm.2020.108408 · Cited by 34
“When appropriate, bleed through between channels was compensated with raw fluorescence data from fluorescence controls using the slope determined by linear regression (Prism, GraphPad) as described by Roederer, 2002.”
MethodQuantitative Flow Cytometry Measurements in Antibodies Bound per Cell Based on a CD4 Reference
Wang, L., Degheidy, H. A., Abbasi, F., Mostowski, H. S., Marti, G. E., Bauer, S. R., Hoffman, R. A., & Gaigalas, A. K. (2016) · Current Protocols in Cytometry · doi:10.1002/0471142956.cy0129s75 · Cited by 34
“Clearly the fluorescence signal in the FC not assigned to a given label fluorophore is a bias and should be corrected using a process called compensation (UNIT 1.14; Roederer, 2002).”
MethodInfluentialMatz, R. L., Erickson, B. W., Vaidyanathan, S., Kukowska‐Latallo, J. F., Baker, J. R., Orr, B. G., & Holl, M. M. B. (2013) · Molecular Pharmaceutics · doi:10.1021/mp300470d · Cited by 35
Salisch, N. C., Gil, A. I., Czapska-Casey, D. N., Vorthoren, L., Serroyen, J., Tolboom, J. T. B. M., Saeland, E., Schuitemaker, H., & Zahn, R. C. (2019) · npj Vaccines · doi:10.1038/s41541-019-0150-4 · Cited by 33
Advantages of full spectrum flow cytometry
Sanders, C. K., & Mourant, J. R. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.3.037004 · Cited by 32
“18(3) Journal of Biomedical Optics 18(3), 037004 (March 2013)”
BackgroundPeripheral blood invariant natural killer T cells throughout pregnancy and in preeclamptic women
Southcombe, J. H., Redman, C. W. G., & Sargent, I. L. (2010) · Journal of Reproductive Immunology · doi:10.1016/j.jri.2010.07.003 · Cited by 30
Feher, K., Kirsch, J., Radbruch, A., Chang, H., & Kaiser, T. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu575 · Cited by 30
“In fact, these are such pervasive problems that a specific type of biological control has been designed for their detection: the fluorescence-minus-one (FMO) control (Roederer, 2002).”
BackgroundAn Anti-Inflammatory Role for NLRP10 in Murine Cutaneous Leishmaniasis
Clay, G. M., Valadares, D. G., Graff, J. W., Ulland, T. K., Davis, R. E., Scorza, B. M., Zhanbolat, B., Chen, Y., Sutterwala, F. S., & Wilson, M. E. (2017) · The Journal of Immunology · doi:10.4049/jimmunol.1500832 · Cited by 30
“Fluorescence minus one controls were used to set all gates (27).”
MethodChaudhary, O., Trotta, D., Wang, K., Wang, X., Chu, X., Bradley, C., Okulicz, J. F., Maves, R. C., Kronmann, K., Schofield, C. M., et al. (2022) · Journal for ImmunoTherapy of Cancer · doi:10.1136/jitc-2022-004564 · Cited by 32
Schneider, L., Marcondes, N. A., Hax, V., Moreira, I. F. D. S., Ueda, C. Y., Piovesan, R. R., Xavier, R. M., & Chakr, R. M. D. S. (2021) · Revista Brasileira de Reumatologia · doi:10.1186/s42358-021-00182-8 · Cited by 31
“Fluorescence-minus-one (FMO) methodology was used to differentiate autoflourescent events from events with low concentrations of cell surface markers [21].”
MethodNovo, D. J. (2022) · Cytometry Part A · doi:10.1002/cyto.a.24669 · Cited by 28
“assume the autofluorescence is similar on all cells, or assume that the autofluorescence is negligible and ignore it [2].”
BackgroundEl‐Hajjar, L., Ahmad, F. A., & Nasr, R. (2023) · Current Protocols · doi:10.1002/cpz1.721 · Cited by 32
“…background and any fluorescent spread from the other fluorochromes into the channel of interest (Busuttil-Crellin et al., 2020; Cossarizza et al., 2017; Dorn-Beineke & Sack, 2016; Maecker & Trotter, 2006; Perfetto et al., 2004; Roederer, 2001; see Current Protocols article: Roederer, 2002) (Fig.”
BackgroundAutoGate: automating analysis of flow cytometry data
Meehan, S., Walther, G., Moore, W., Orlova, D. Y., Meehan, C., Parks, D. R., Ghosn, E., Philips, M., Mitsunaga, E. M., Waters, J., et al. (2014) · Immunologic Research · doi:10.1007/s12026-014-8519-y · Cited by 28
Zhang, W., Nilles, T. L., Johnson, J. R., & Margolick, J. B. (2016) · Journal of Immunological Methods · doi:10.1016/j.jim.2016.02.004 · Cited by 26
“For all flow cytometry analyses, fluorescence-minus-one controls (Roederer, 2002) were applied to set appropriate analysis thresholds.”
Hunka, J., Riley, J. T., & Debes, G. F. (2020) · BMC Veterinary Research · doi:10.1186/s12917-020-02299-2 · Cited by 26
“T cells; the approach is less suitable for co-expression studies [24, 38].”
BackgroundDevelopment of gut-homing receptors on circulating B cells during infancy
Lundell, A., Rabe, H., Quiding‐Järbrink, M., Andersson, K., Nordström, I., Adlerberth, I., Wold, A. E., & Rudin, A. (2010) · Clinical Immunology · doi:10.1016/j.clim.2010.10.003 · Cited by 25
Bridging the Gap: A Roadmap to Breaking the Biological Design Barrier
Beal, J. (2015) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2014.00087 · Cited by 26
“The TASBE method (Beal et al., 2012) builds on prior methods for flow cytometry calibration (Roederer, 2001, 2002; Schwartz et al., 2004; Hoffman et al., 2012), enhancing them to allow equivalent units to be read from all channels of a flow cytometer.”
Lingblom, C., Wallander, J., Ingelsten, M., Bergquist, H., Bove, M., Saalman, R., Welin, A., & Wennerås, C. (2016) · Clinical & Experimental Immunology · doi:10.1111/cei.12898 · Cited by 25
Carbajal, A. G., Bavencoffe, A. G., Walters, E. T., & DESSAUER, C. W. (2020) · Journal of Neuroscience · doi:10.1523/jneurosci.0810-20.2020 · Cited by 26
“The slope of best linear fit was determined by linear regression (Prism, GraphPad) and used to compensate spillover as described previously (Roederer, 2002).”
MethodMonserrat, J., Sánchez, M. Á., de Paz, R., Díaz, D., Mur, S. M., Reyes, E., I, A. P., de la Hera, A., Martínez‐A, C., & Álvarez‐Mon, M. (2013) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.21120 · Cited by 24
“Appay V, van Lier RA, Sallusto F, Roederer M. Phenotype and function of human T lymphocyte subsets: Consensus and issues.”
MethodInfluentialIntroduction to Multiparametric Flow Cytometry and Analysis of High-Dimensional Data
Sun, J. X., Kroeger, J. L., & Markowitz, J. (2020) · Methods in molecular biology · doi:10.1007/978-1-0716-0849-4_13 · Cited by 25
Wojciechowski, S., Virenque, A., Vihma, M., Galbardi, B., Rooney, E. J., Keuters, M. H., Antila, S., Koıstınaho, J., & Noè, F. M. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2020.559810 · Cited by 23
“These control samples contained all antibodies except one to display fluorescent spreading error of compensated data in each channel (31).”
BackgroundSong, Y., & Lee, Y. (2024) · Molecules and Cells · doi:10.1016/j.mocell.2024.100129 · Cited by 24
TASBE Flow Analytics: A Package for Calibrated Flow Cytometry Analysis
Beal, J., Overney, C., Adler, A., Yaman, F., Tiberio, L., & Samineni, M. (2019) · ACS Synthetic Biology · doi:10.1021/acssynbio.8b00533 · Cited by 22
Human Lymphoid Development in the Absence of Common γ-Chain Receptor Signaling
Kohn, L. A., Seet, C. S., Scholes, J., Codrea, F., Chan, R., Zaidi-Merchant, S., Zhu, Y., Oliveira, S. N. D., Kapoor, N., Shah, A. J., et al. (2014) · The Journal of Immunology · doi:10.4049/jimmunol.1303496 · Cited by 24
“B1 cells were defined as DAPI(2)CD20CD27CD43CD3(2) as described previously (34, 35); B1 cell gating was defined by negative controls using the florescent minus one technique (36).”
MethodTauschmann, M., Prietl, B., Treiber, G. M., Gorkiewicz, G., Kump, P. K., Högenauer, C., & Pieber, T. R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080362 · Cited by 24
“Gates and quadrants were set based on isotype control staining and FMO-controls (Fluorescence Minus One) [27].”
MethodStudying the Human Immunome: The Complexity of Comprehensive Leukocyte Immunophenotyping
Biancotto, A., & McCoy, J. P. (2013) · Current topics in microbiology and immunology · doi:10.1007/82_2013_336 · Cited by 22
“For this reason, one can use beads that bind to the Fc region of antibodies, and thus obtain a non-antigen binding, positive staining with high fluorescence intensity to determine compensation (Roederer 2002).”
BackgroundPolychromatic flow cytometry in the clinical laboratory
Sewell, W. A., & Smith, S. A. B. C. (2011) · Pathology · doi:10.1097/pat.0b013e32834a69ae · Cited by 22
“Compensation can be performed by labelling either cells or antibody capture beads with the antibody of interest.(9,77,82,85) Cells have the advantage that any background factors are taken into account, and forward scatter and side scatter can be set at the same time.”
BackgroundZhang, Y., Planas, D., Marchand, L. R., Massanella, M., Chen, H., Wacleche, V. S., Gosselin, A., Goulet, J.-P., Filion, M., Routy, J., et al. (2020) · Frontiers in Microbiology · doi:10.3389/fmicb.2020.00902 · Cited by 22
“Flow cytometry gates were defined using the fluorescence minus one (FMO) strategy (Roederer, 2002; Gosselin et al., 2010).”
MethodGarg, A., Yuen, S., Seekhao, N., Yu, G., Karwowsky, J., Powell, M. D., Sakata, J. T., Mongeau, L., JáJá, J. F., & Li‐Jessen, N. Y. K. (2019) · Applied Sciences · doi:10.3390/app9152974 · Cited by 20
“His48 was used to separate His48+CD31+ neutrophils from His48-CD31+ macrophages by using a His48 vs CD31 gate [80,81].”
MethodInfluentialRöderer, P., Belu, A., Heidrich, L., Siobal, M., Isensee, J., Prolingheuer, J., Janocha, E., Valdor, M., Hagendorf, S., Bahrenberg, G., et al. (2023) · Pain · doi:10.1097/j.pain.0000000000002860 · Cited by 19
Lingblom, C., Bergquist, H., Johnsson, M., Sundström, P., Quiding‐Järbrink, M., Bove, M., & Wennerås, C. (2014) · Inflammation · doi:10.1007/s10753-014-9926-x · Cited by 19
“Instead of multiple isotype controls, “fluorescence-minus-one” technique was employed [16].”
MethodArger, N., Machiraju, S. N., Allen, I. E., Woodruff, P. G., & Koth, L. L. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.01129 · Cited by 20
Ab initio spillover compensation in mass cytometry data
Miao, Q., Wang, F., Dou, J., Iqbal, R., Müftüoğlu, M., Başar, R., Li, L., Rezvani, K., & Chen, K. (2020) · Cytometry Part A · doi:10.1002/cyto.a.24298 · Cited by 19
“The spillover compensation problem in CyTOF data is similar to the complete compensation problem defined in flow cytometry literate.(9) Let”
Isensee, J., Schild, C., Schwede, F., & Hucho, T. B. (2017) · Journal of Cell Science · doi:10.1242/jcs.197327 · Cited by 20
“controls were used to calculate the slope of best fit straight lines by linear regression, which was then used to compensate spill-over as described previously (Roederer, 2002).”
Method
Metadata
- Authors
- Roederer, M.
- Affiliations
- National Institutes of Health (US)
- Corresponding author
- Roederer, Mario
- ORCID
- Roederer, Mario
- Venue
- Current Protocols in Cytometry
- Publisher
- Wiley
- Published
- 2002-10
- Volume
- 22
- Issue
- 1
- Pages
- Unit 1.14-Unit 1.14
- ISSN
- 1934-9297 (ISSN-L)
- 1934-9300
- OpenAlex
- W1951089650
- Cited by
- 228
- References
- 6
- Citations by year
- 2026: 7 · 2025: 15 · 2024: 13 · 2023: 14 · 2022: 19 · 2021: 19 · 2020: 30 · 2019: 15 · 2018: 8 · 2017: 14 · 2016: 12 · 2015: 11 · 2014: 8 · 2013: 18 · 2012: 4
- FWCI
- 0.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Current Protocols in Cytometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- compensation, multiparameter flow cytometry, software compensation, compensation control, data visualization
- MeSH terms
- Flow Cytometry, Fluorescent Dyes, Leukocytes, Mononuclear, Microspheres, Phycoerythrin, Fluorescein-5-isothiocyanate, Fluorescence Resonance Energy Transfer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.