Compensation in Flow Cytometry
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Many people using multi‐color flow cytometry do not understand what compensation is, when it is needed, or how it should be applied. The author provides a clear explanation of the nature of compensation, the factors that affect compensation values, and the effect of compensation on data visualization. Both hardware and software compensation are covered. Although the subject is treated from a mathematical perspective, the manner of presentation is very straightforward. The unit discusses appropriate controls and protocols to check compensation settings, as well as introducing the concept of fluorescence‐minus‐one gates. Many example figures are supplied to give the reader a clear indication of how the author believes compensation should be handled. Keywords: flow cytometry; spectral compensation; fluorescence spillover; autofluorescence; fluorescence minus one
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is not possible to interpret data from multiparameter flow cytometry without including these essential controls [6].”
From Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition) (2021) · cites this paper as [6]
Citations
Cites
Spectral compensation for flow cytometry: Visualization artifacts, limitations, and caveats
Roederer, M. (2001) · Cytometry · doi:10.1002/1097-0320(20011101)45:3<194::aid-cyto1163>3.0.co;2-c · Cited by 558 · cited 2×
“While there are small errors in the electronics that can contribute to this spread, the most significant source of error is photon-counting statistics (Roederer, 2001).”
BackgroundSelf-citationTwo-color immunofluorescence using a fluorescence-activated cell sorter.
Loken, M. R., Parks, D. R., & Herzenberg, L. A. (1977) · Journal of Histochemistry & Cytochemistry · doi:10.1177/25.7.330738 · Cited by 193
Fluorescence Spectral Overlap Compensation for Any Number of Flow Cytometry Parameters
Bagwell, C. B., & Adams, E. G. (1993) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1993.tb38775.x · Cited by 157 · cited 1×
“This topic is dealt with in detail by Bagwell and Adams (1993).”
BackgroundHandbook of Experimental Immunology
Mellors, R. C. (1969) · American Journal of Clinical Pathology · doi:10.1093/ajcp/51.5.657 · Cited by 105
A single laser method for subtraction of cell autofluorescence in flow cytometry
Alberti, S., Parks, D. R., & Herzenberg, L. A. (1987) · Cytometry · doi:10.1002/cyto.990080203 · Cited by 98
Roederer, M., & Murphy, R. F. (1986) · Cytometry · doi:10.1002/cyto.990070610 · Cited by 95 · cited 1×
“Autofluorescence compensation is more fully described in published references by Roederer and Murphy (1986) and Alberti et al. (1987).”
BackgroundSelf-citation
Cited by
Items 201–235 of 235
Alternative Approaches for Analysis of Complex Data Sets in Flow Cytometry
Gondhalekar, C. (2017) · Series in bioengineering · doi:10.1007/978-981-10-4499-1_9 · Cited by 1
Ortolani, C. (2022) · Springer eBooks · doi:10.1007/978-3-031-10836-5_19 · Cited by 1
Buxbaum, E. (2025) · Springer eBooks · doi:10.1007/978-1-0716-4124-8_4 · Cited by 1
A Survey of Preprocessing Techniques for Flow Cytometry Data in Classification Tasks
Núñez-Nepomuceno, D., Sáez, J. A., & Carmona‐Sáez, P. (2025) · IEEE Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbbio.2025.3612573 · Cited by 1
Hersperger, A. R. (2010) · ScholarlyCommons (University of Pennsylvania)
Response to editorial by Mario Roederer
Stewart, C. C., & Stewart, S. J. (2001) · Cytometry · doi:10.1002/cyto.10044
Ernst, P. B., Erickson, L. D., Loo, W. M., Scott, K. G., Wiznerowicz, E. B., Brown, C. C., Torres-Velez, F. J., Alam, M. S., Black, S. G., MCDUFFIE, M. J., et al. (2011) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00194.2011
“Controls included beads coated with each antibody for compensation, and gates were set using gastric MNC labeled with combinations of all antibodies minus one (36), such that 97.”
MethodSpectral Compensation for Linear-Logarithmic Flow Cytometry Acquisitions
van Rodijnen, N., Pieters, M., & Nap, M. (2014) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2014.79063
“7) Compensation of the FL2 signal is performed by subtraction of the compensation value times the primary fluorescence in FL1 from the total fluorescence acquired in FL2 [1] [2] [4] [5] [8] [11] [12].”
BackgroundDong, H. P. (2013) · NVA (Nasjonalt vitenarkiv)
Evaluation of T Cell Function in Allergic Disease
Barker, B. R. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-496-8_3
Chemometrics in Flow Cytometry
Tinnevelt, G. H., & Jansen, J. J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.14596-2
Ablation of FAP+ stromal cells impairs endogenous revascularization during hind limb ischemia
Chao, J. C. (2020) · Arrow@dit (Dublin Institute of Technology) · doi:10.13025/17523
Bhowmick, D., van Diepen, F. N. J., Pfauth, A., Tissier, R., & Ratliff, M. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.10.31.363150
“Recent developments in Flow Cytometry and fluorochrome technology have made it possible to combine a large number of fluorescent labels to enumerate immune cell subsets and interrogate protein expression from a single biological sample [1].”
BackgroundChikina, A. S., Nadalin, F., Maurin, M., Jouve, M. J., Thomas-Bonafos, T., Li, X. V., Lameiras, S., Baulande, S., Henri, S., MALISSEN, B., et al. (2020) · SSRN Electronic Journal · doi:10.2139/ssrn.3582693
PAK5 is a potential target in myelodysplastic syndrome through interacting with LMO2 and GATA1
Pan, X., Liu, D., Ying, M., Zheng, G., Fan, C.-M., Pan, F., & Ke, Q. (2022) · Cellular and Molecular Biology · doi:10.14715/cmb/2022.68.9.12
Arrojo, M. L. (2024) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.17.2024.tde-13052024-152548
Lam, K. C., Chen, Q., & Goldszmid, R. S. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.07.23.604694
Saxena, A., Biancotto, A., Dagur, P. K., & McCoy, J. P. (2024) · Wiley eBooks · doi:10.1002/9781683674023.ch14
Highly Efficient Calibration‐Free Color Compensation Algorithm for Imaging Flow Cytometry
Zhou, Z., Lai, Z., Tang, R. H., Chen, X., Qu, Y., Xia, L., George, M., Munoz, A., Zhou, M., Tai, Y., et al. (2025) · Cytometry Part A · doi:10.1002/cyto.a.24931
“The earliest compensation methods involved directly calculating the spillover coefficients between different channels based on the filter's bandwidth and the fluorescence spectrum [17].”
Quantification of Adipogenesis Using Flow Cytometry
Babbo, C. C.-R., Durandt, C., Ambele, M. A., & Pepper, M. S. (2025) · Methods in molecular biology · doi:10.1007/978-1-0716-4607-6_2
Gerninghaus, H., Isensee, J., Kennel, L., Zhou, F., Kaiser, A., Gross, T., Flauaus, C., Engel, P., Jacobs, C., Petersen, J., et al. (2025) · Science Signaling · doi:10.1126/scisignal.adq4238
Ca V 1.2-dependent excitation-transcription coupling modulates nociceptionPreprint
Isensee, J., Engel, P., Chung, P. C. S., Lin, C., Dohai, B., Löchte, M., Siobal, M., Ostermann, P. N., Dinnendahl, R., Eberhardt, M. J., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.06.25.661480
Paschke, L. (2025) · University of Regensburg Publication Server (University of Regensburg) · doi:10.5283/epub.75034
Kmet, R., & Novo, D. (2026) · Cytometry Part A · doi:10.1002/cytoa.70005
“The empirical estimation of M follows well-established experimental protocols involving single-stained control samples [1, 5, 6].”
Etude du stroma de tumeurs mammaires humaines xénogreffées et de modèles transgéniques murins
Vallerand, D. (2014) · theses.fr (ABES) · doi:10.70675/70101d12z5b0fz4325za8e3z06c0b1a0036d
Découverte de marqueurs immunologiques permettant d’évaluer l’innocuité des nouveaux vaccins
Pereira, A. L. (2018) · theses.fr (ABES) · doi:10.70675/97571306zf33dz40dcz9c00z698f1f1c4a5c
Role of macrophages in colon homeostasis
Chikina, A. S. (2020) · theses.fr (ABES) · doi:10.70675/914bf102zc92ez4351zb4dbz1945d4116eea
Flow Cytometry Data: Processing, Analysis, Artifacts, and Pitfalls
Wang, X. (2026) · Cambridge University Press eBooks · doi:10.1017/9781009397797.041
Dias, J., Far, M. E., Boczar, K. E., Filali-Mouhim, A., Benlarbi, M., Gabriel, E. M., Moreaux, J., Khalfi, S., Salinas, T. R. W., Messier-Peet, M., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.08.20.746037
CaptureBody enables accurate unmixing for spectral flow cytometry
Zambidis, A. E., Siddaramaiah, L. K., Gray, M., Konecny, A., & Prlic, M. (2026) · Cell Reports Methods · doi:10.1016/j.crmeth.2026.101571
DNA ploidy analysis of body fluids and cerebrospinal fluid
Dhanasekaran, V., Awasthi, N. P., Sharma, P., & Mallik, N. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-27426-8.00015-6
Metadata
- Authors
- Roederer, M.
- Affiliations
- National Institutes of Health (US)
- Corresponding author
- Roederer, Mario
- ORCID
- Roederer, Mario
- Venue
- Current Protocols in Cytometry
- Publisher
- Wiley
- Published
- 2002-10
- Volume
- 22
- Issue
- 1
- Pages
- Unit 1.14-Unit 1.14
- ISSN
- 1934-9297 (ISSN-L)
- 1934-9300
- OpenAlex
- W1951089650
- Semantic Scholar
- c5a0a90fd59a12cd08c51284a73304f65856305f
- Cited by
- 228
- References
- 6
- Citations by year
- 2026: 7 · 2025: 15 · 2024: 13 · 2023: 14 · 2022: 19 · 2021: 19 · 2020: 30 · 2019: 15 · 2018: 8 · 2017: 14 · 2016: 12 · 2015: 11 · 2014: 8 · 2013: 18 · 2012: 4
- FWCI
- 0.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Current Protocols in Cytometry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- compensation, multiparameter flow cytometry, software compensation, compensation control, data visualization
- MeSH terms
- Flow Cytometry, Fluorescent Dyes, Leukocytes, Mononuclear, Microspheres, Phycoerythrin, Fluorescein-5-isothiocyanate, Fluorescence Resonance Energy Transfer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.