Using ProSight PTM and Related Tools for Targeted Protein Identification and Characterization with High Mass Accuracy Tandem MS Data
The DOI matches its Crossref record.
Abstract
ProSight PTM v2.0, neuroProSight, and the Sequence Gazer allow the identification and characterization of proteins from high mass accuracy tandem mass spectrometric data of intact proteins and large peptides. Input data consists of one or more neutral precursor ion masses and a set of neutral b/y or c/z. fragment ions masses. This data is compared against “shotgun annotated” proteome databases or known protein sequences. With these tools it is possible to not only identify unknown proteins, but to determine the location of post‐translational modifications (PTM) with 100% sequence coverage. Collectively, the tools create a search environment that allows five different search modes, including absolute mass and sequence tag searching, which are conveniently employed via a graphical user interface. Data management and chemical noise reduction tools are also available. These tools provide a complete environment for the identification and characterization of proteins from high resolution tandem mass spectrometry of intact proteins and large peptides. Curr. Protoc. Bioinform. 19:13.6.1‐13.6.28. © 2007 by John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Precision proteomics: The case for high resolution and high mass accuracy
Mann, M., & Kelleher, N. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800788105 · Cited by 450
“ProSight is the first high-throughput search environment to support error-tolerant proteomics based on resolved isotopic distributions for 3- to 40-kDa fragment ions, and uses a candidate expansion approach in a preconstructed database to expose known proteomic information for primary database searches (58).”
Self-citationMichalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373
Zamdborg, L., LeDuc, R. D., Glowacz, K. J., Kim, Y.-B., Viswanathan, V., Spaulding, I. T., Early, B. P., Bluhm, E. J., Babai, S., & Kelleher, N. L. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm371 · Cited by 251
Self-citationOn the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
Self-citationOptimizing capillary electrophoresis for top‐down proteomics of 30–80 kDa proteins
Li, Y., Compton, P. D., Tran, J. C., Ntai, I., & Kelleher, N. L. (2014) · PROTEOMICS · doi:10.1002/pmic.201300381 · Cited by 95
“Each precursor ion was searched against the database using a 100 000 Da window and fragment ions were matched using an absolute mass search logic with a tolerance of 10 ppm [23].”
MethodSelf-citation
Metadata
- Authors
- D. LeDuc, R., & L. Kelleher, N.
- Venue
- Current Protocols in Bioinformatics
- Publisher
- Wiley
- Published
- 2007-09
- Volume
- 19
- Issue
- 1
- Pages
- Unit 13.6-Unit 13.6
- ISSN
- 1934-3396 (ISSN-L)
- 1934-340X
- OpenAlex
- W2100051497
- Cited by
- 42
- References
- 0
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using ProSight PTM and Related Tools for Targeted Protein Identification and Characterization with High Mass Accuracy Tandem MS Data. https://app.cochat.ai/papers/10.1002/0471250953.bi1306s19
- The paper
- D. LeDuc, R., & L. Kelleher, N. (2007). Using ProSight PTM and Related Tools for Targeted Protein Identification and Characterization with High Mass Accuracy Tandem MS Data. Current Protocols in Bioinformatics. https://doi.org/10.1002/0471250953.bi1306s19
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.