The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Bispectral index for improving anaesthetic delivery and postoperative recovery
Open accessAbstract
BACKGROUND: The use of clinical signs may not be reliable in measuring the hypnotic component of anaesthesia. The use of bispectral index (BIS) to guide the dose of anaesthetic may have certain advantages over clinical signs. This is the second update of a review originally published in 2007. OBJECTIVES: The primary objective of this review focused on whether the incorporation of BIS into the standard practice for management of anaesthesia can reduce the risk of intraoperative awareness, consumption of anaesthetic agents, recovery time and total cost of anaesthesia in surgical patients undergoing general anaesthesia. SEARCH METHODS: In this updated version, we searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 1), MEDLINE (1990 to 31 January 2013), EMBASE (1990 to 31 January 2013) and reference lists of articles. Previously, we searched to May 2009. SELECTION CRITERIA: We included randomized controlled trials comparing BIS with standard practice criteria for titration of anaesthetic agents. DATA COLLECTION AND ANALYSIS: Two authors independently assessed trial quality, extracted data and analysed the data. We contacted study authors for further details. MAIN RESULTS: We included 36 trials. In studies using clinical signs as standard practice, the results demonstrated a significant effect of the BIS-guided anaesthesia in reducing the risk of intraoperative awareness among surgical patients at high risk for awareness (7761 participants; odds ratio (OR) 0.24, 95% confidence interval (CI) 0.12 to 0.48). This effect was not demonstrated in studies using end tidal anaesthetic gas (ETAG) monitoring as standard practice (26,530 participants; OR 1.13, 95% CI 0.56 to 2.26). BIS-guided anaesthesia reduced the requirement for propofol by 1.32 mg/kg/hr (672 participants; 95% CI -1.91 to -0.73) and for volatile anaesthetics (desflurane, sevoflurane, isoflurane) by 0.65 minimal alveolar concentration equivalents (MAC) (95% CI -1.01 to -0.28) in 985 participants. Irrespective of the anaesthetics used, BIS reduced the following recovery times: time for eye opening (2557 participants; by 1.93 min, 95% CI -2.70 to -1.16), response to verbal command (777 participants; by 2.73 min, 95% CI -3.92 to -1.54), time to extubation (1501 participants; by 2.62 min, 95% CI -3.46 to -1.78), and time to orientation (373 participants; by 3.06 min, 95% CI -3.63 to -2.50). BIS shortened the duration of postanaesthesia care unit stay by 6.75 min (1953 participants; 95% CI -11.20 to -2.31) but did not significantly reduce the time to home readiness (329 participants; -7.01 min, 95% CI -30.11 to 16.09). AUTHORS' CONCLUSIONS: BIS-guided anaesthesia can reduce the risk of intraoperative awareness in surgical patients at high risk for awareness in comparison to using clinical signs as a guide for anaesthetic depth. BIS-guided anaesthesia and ETAG-guided anaesthesia may be equivalent in protection against intraoperative awareness but the evidence for this is inconclusive. In addition, anaesthesia guided by BIS kept within the recommended range improves anaesthetic delivery and postoperative recovery from relatively deep anaesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimating the mean and variance from the median, range, and the size of a sample
Hozo, S. P., Djulbegovic, B., & Hozo, I. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-13 · Cited by 9,062
Davis, H. S. (1966) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1966.03100200106038 · Cited by 1,719
A Primer for EEG Signal Processing in Anesthesia
Rampil, I. J. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00023 · Cited by 1,503
(2010) · Handbook of Disease Burdens and Quality of Life Measures · doi:10.1007/978-0-387-78665-0_6514 · Cited by 1,385
Myles, P., Leslie, K., McNeil, J., Forbes, A., & Chan, M. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16300-9 · Cited by 1,301
Glass, P. S., Bloom, M., Kearse, L., Rosow, C., Sebel, P., & Manberg, P. (1997) · Anesthesiology · doi:10.1097/00000542-199704000-00014 · Cited by 1,274
Published by John Wiley & Sons Ltd
Modarresi, O. A. F., & Shakibaie, M. M. M. R. (2015) · Cited by 1,111
Anesthesia Awareness and the Bispectral Index
Avidan, M. S., Zhang, L., Burnside, B. A., Finkel, K. J., Searleman, A. C., Selvidge, J. A., Saager, L., Turner, M. S., Rao, S., Bottros, M., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0707361 · Cited by 975
The Incidence of Awareness During Anesthesia: A Multicenter United States Study
Sebel, P. S., Bowdle, T. A., Ghoneim, M. M., Rampil, I. J., Padilla, R. E., Gan, T. J., & Domino, K. B. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000130261.90896.6c · Cited by 722
Gan, T. J., Glass, P. S. A., Windsor, A. C. J., Payne, F. C., Rosow, C. E., Sebel, P. S., & Manberg, P. J. (1997) · Anesthesiology · doi:10.1097/00000542-199710000-00014 · Cited by 691
Cited by
Nygren, J., Thacker, J., Carli, F., Fearon, K. C. H., Norderval, S., Lobo, D. N., Ljungqvist, O., Soop, M., & Ramirez, J. (2013) · World Journal of Surgery · doi:10.1007/s00268-012-1787-6 · Cited by 2,171
Gustafsson, U. O., Scott, M. J., Hubner, M., Nygren, J., Demartines, N., Francis, N., Rockall, T. A., Young‐Fadok, T. M., Hill, A. G., Soop, M., et al. (2019) · World Journal of Surgery · doi:10.1007/s00268-018-4844-y · Cited by 2,119
Gustafsson, U. O., Scott, M. J., Schwenk, W., Demartines, N., Roulin, D., Francis, N., McNaught, C. E., MacFie, J., Liberman, A. S., Soop, M., et al. (2013) · World Journal of Surgery · doi:10.1007/s00268-012-1772-0 · Cited by 1,082
Anesthesia Awareness and the Bispectral Index
Avidan, M. S., Zhang, L., Burnside, B. A., Finkel, K. J., Searleman, A. C., Selvidge, J. A., Saager, L., Turner, M. S., Rao, S., Bottros, M., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0707361 · Cited by 975
Gustafsson, U. O., Scott, M. J., Schwenk, W., Demartines, N., Roulin, D., Francis, N., McNaught, C. E., MacFie, J., Liberman, A. S., Soop, M., et al. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.08.013 · Cited by 839
Consensus guidelines for enhanced recovery after gastrectomy
Mortensen, K., Nilsson, M., Slim, K., Schäfer, M., Mariette, C., Braga, M., Carli, F., Demartines, N., Griffin, S. M., Lassen, K., et al. (2014) · British Journal of Surgery · doi:10.1002/bjs.9582 · Cited by 767
Nelson, G., Bakkum-Gamez, J., Kalogera, E., Glaser, G., Altman, A., Meyer, L. A., Taylor, J. S., Iniesta, M., Lasala, J., Mena, G., et al. (2019) · International Journal of Gynecological Cancer · doi:10.1136/ijgc-2019-000356 · Cited by 758
Feldheiser, A., Aziz, O., Baldini, G., Cox, B. P. B. W., Fearon, K. C. H., Feldman, L. S., Gan, T. J., Kennedy, R. H., Ljungqvist, O., Lobo, D. N., et al. (2016) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12651 · Cited by 714
Low, D. E., Allum, W., De Manzoni, G., Ferri, L., Immanuel, A., Kuppusamy, M., Law, S., Lindblad, M., Maynard, N., Neal, J., et al. (2019) · World Journal of Surgery · doi:10.1007/s00268-018-4786-4 · Cited by 641
Prevention of Intraoperative Awareness in a High-Risk Surgical Population
Avidan, M. S., Jacobsohn, E., Glick, D., Burnside, B. A., Zhang, L., Villafranca, A., Karl, L., Kamal, S., Torres, B., O'Connor, M., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1100403 · Cited by 581
Nelson, G., Altman, A. D., Nick, A., Meyer, L. A., Ramirez, P. T., Achtari, C., Antrobus, J., Huang, J., Scott, M., Wijk, L., et al. (2016) · Gynecologic Oncology · doi:10.1016/j.ygyno.2015.12.019 · Cited by 562
Radtke, F. M., Franck, M., Lendner, J., Krüger, S., Wernecke, K. D., & Spies, C. D. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet055 · Cited by 532
Nelson, G., Altman, A. D., Nick, A., Meyer, L. A., Ramirez, P. T., Achtari, C., Antrobus, J., Huang, J., Scott, M., Wijk, L., et al. (2016) · Gynecologic Oncology · doi:10.1016/j.ygyno.2015.11.015 · Cited by 458
Sessler, D. I., Sigl, J. C., Kelley, S. D., Chamoun, N. G., Manberg, P. J., Saager, L., Kurz, A., & Greenwald, S. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31825683dc · Cited by 429
Gustafsson, U. O., Rockall, T. A., Wexner, S., How, K. Y., Emile, S., Marchuk, A., Fawcett, W. J., Sioson, M., Riedel, B., Chahal, R., et al. (2025) · Surgery · doi:10.1016/j.surg.2025.109397 · Cited by 373
Miller, D., Lewis, S. R., Pritchard, M. W., Schofield-Robinson, O. J., Shelton, C. L., Alderson, P., & Smith, A. F. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012317.pub2 · Cited by 310
Nimmo, A. F., Absalom, A. R., Bagshaw, O., Biswas, A., Cook, T. M., Costello, A., Grimes, S., Mulvey, D., Shinde, S., Whitehouse, T., et al. (2019) · Anaesthesia · doi:10.1111/anae.14428 · Cited by 295
Response of bispectral index to neuromuscular block in awake volunteers
Schuller, P. J., Newell, S., Strickland, P. A., & Barry, J. J. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev072 · Cited by 258
Yavchitz, A., Ravaud, P., Altman, D. G., Moher, D., Hrobjartsson, A., Lasserson, T., & Boutron, I. (2016) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2016.01.020 · Cited by 224
Current status of EEG-based depth-of-consciousness monitoring during general anesthesia
Musialowicz, T., & Lahtinen, P. (2014) · Current Anesthesiology Reports · doi:10.1007/s40140-014-0061-x · Cited by 33
Metadata
- Authors
- Punjasawadwong, Y., Phongchiewboon, A., & Bunchungmongkol, N.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2014-06-17
- Issue
- 6
- Pages
- CD003843-CD003843
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2140902586
- Cited by
- 449
- References
- 41
- FWCI
- 43.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.