The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Magnetic resonance imaging versus computed tomography for detection of acute vascular lesions in patients presenting with stroke symptoms
Open accessAbstract
BACKGROUND: Magnetic resonance imaging (MRI) is increasingly used for the diagnosis of acute ischaemic stroke but its sensitivity for the early detection of intracerebral haemorrhage has been debated. Computed tomography (CT) is extensively used in the clinical management of acute stroke, especially for the rapid exclusion of intracerebral haemorrhage. OBJECTIVES: To compare the diagnostic accuracy of diffusion-weighted MRI (DWI) and CT for acute ischaemic stroke, and to estimate the diagnostic accuracy of MRI for acute haemorrhagic stroke. SEARCH STRATEGY: We searched MEDLINE and EMBASE (January 1995 to March 2009) and perused bibliographies of relevant studies for additional references. SELECTION CRITERIA: We selected studies that either compared DWI and CT in the same patients for detection of ischaemic stroke or examined the utility of MRI for detection of haemorrhagic stroke, had imaging performed within 12 hours of stroke onset, and presented sufficient data to allow construction of contingency tables. DATA COLLECTION AND ANALYSIS: Three authors independently extracted data on study characteristics and measures of accuracy. We assessed data on ischaemic stroke using random-effects and fixed-effect meta-analyses. MAIN RESULTS: Eight studies with a total of 308 participants met our inclusion criteria. Seven studies contributed to the assessment of ischaemic stroke and two studies to the assessment of haemorrhagic stroke. The spectrum of patients was relatively narrow in all studies, sample sizes were small, there was substantial incorporation bias, and blinding procedures were often incomplete. Amongst the patients subsequently confirmed to have acute ischaemic stroke (161/226), the summary estimates for DWI were: sensitivity 0.99 (95% CI 0.23 to 1.00), specificity 0.92 (95% CI 0.83 to 0.97). The summary estimates for CT were: sensitivity 0.39 (95% CI 0.16 to 0.69), specificity 1.00 (95% CI 0.94 to 1.00). The two studies on haemorrhagic stroke reported high estimates for diffusion-weighted and gradient-echo sequences but had inconsistent reference standards. We did not calculate overall estimates for these two studies. We were not able to assess practicality or cost-effectiveness issues. AUTHORS' CONCLUSIONS: DWI appears to be more sensitive than CT for the early detection of ischaemic stroke in highly selected patients. However, the variability in the quality of included studies and the presence of spectrum and incorporation biases render the reliability and generalisability of observed results questionable. Further well-designed studies without methodological biases, in more representative patient samples, with practicality and cost estimates are now needed to determine which patients should undergo MRI and which CT in suspected acute stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Hacke, W., Kaste, M., Fieschi, C., von Kummer, R., Davalos, A., Meier, D., Larrue, V., Bluhmki, E., Davis, S., Donnan, G., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(98)08020-9 · Cited by 3,662
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Classification and natural history of clinically identifiable subtypes of cerebral infarction
Bamford, J., Sandercock, P., Dennis, M., Warlow, C., & Burn, J. (1991) · The Lancet · doi:10.1016/0140-6736(91)93206-o · Cited by 3,294
Self-citationTowards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Feigin, V. L., Lawes, C. M., Bennett, D. A., & Anderson, C. S. (2003) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00266-7 · Cited by 1,932
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Cited by
Jauch, E. C., Saver, J. L., Adams, H. P., Bruno, A., Connors, J. J. (., Demaerschalk, B. M., Khatri, P., McMullan, P. W., Qureshi, A. I., Rosenfield, K., et al. (2013) · Stroke · doi:10.1161/str.0b013e318284056a · Cited by 7,634
Powers, W. J., Rabinstein, A. A., Ackerson, T., Adeoye, O. M., Bambakidis, N. C., Becker, K., Biller, J., Brown, M., Demaerschalk, B. M., Hoh, B., et al. (2019) · Stroke · doi:10.1161/str.0000000000000211 · Cited by 7,468
Powers, W. J., Rabinstein, A. A., Ackerson, T., Adeoye, O. M., Bambakidis, N. C., Becker, K., Biller, J., Brown, M., Demaerschalk, B. M., Hoh, B., et al. (2018) · Stroke · doi:10.1161/str.0000000000000158 · Cited by 5,446
Sacco, R. L., Kasner, S. E., Broderick, J. P., Caplan, L. R., Connors, J. J. (., Culebras, A., Elkind, M. S. V., George, M. G., Hamdan, A. D., Higashida, R. T., et al. (2013) · Stroke · doi:10.1161/str.0b013e318296aeca · Cited by 3,569
Derdeyn, C. P., Zipfel, G. J., Albuquerque, F. C., Cooke, D. L., Feldmann, E., Sheehan, J. P., & Torner, J. C. (2017) · Stroke · doi:10.1161/str.0000000000000134 · Cited by 395
Metadata
- Authors
- Brazzelli, M., Sandercock, P. A., Chappell, F. M., Celani, M. G., Righetti, E., Arestis, N., Wardlaw, J. M., & Deeks, J. J.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2009-10-07
- Volume
- 2010
- Issue
- 1
- Pages
- CD007424-CD007424
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2148323585
- Cited by
- 161
- References
- 8
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.