Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 433

The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.

Fetal and umbilical Doppler ultrasound in high-risk pregnancies

Open access
Alfirevic, Zarko, Stampalija, Tamara, Gyte, Gillian ML·2013·Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Abnormal blood flow patterns in fetal circulation detected by Doppler ultrasound may indicate poor fetal prognosis. It is also possible that false positive Doppler ultrasound findings could lead to adverse outcomes from unnecessary interventions, including preterm delivery. OBJECTIVES: The objective of this review was to assess the effects of Doppler ultrasound used to assess fetal well-being in high-risk pregnancies on obstetric care and fetal outcomes. SEARCH METHODS: We updated the search of Cochrane Pregnancy and Childbirth's Trials Register on 31 March 2017 and checked reference lists of retrieved studies. SELECTION CRITERIA: Randomised and quasi-randomised controlled trials of Doppler ultrasound for the investigation of umbilical and fetal vessels waveforms in high-risk pregnancies compared with no Doppler ultrasound. Cluster-randomised trials were eligible for inclusion but none were identified. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed the studies for inclusion, assessed risk of bias and carried out data extraction. Data entry was checked. We assessed the quality of evidence using the GRADE approach. MAIN RESULTS: Nineteen trials involving 10,667 women were included. Risk of bias in trials was difficult to assess accurately due to incomplete reporting. None of the evidence relating to our main outcomes was graded as high quality. The quality of evidence was downgraded due to missing information on trial methods, imprecision in risk estimates and heterogeneity. Eighteen of these studies compared the use of Doppler ultrasound of the umbilical artery of the unborn baby with no Doppler or with cardiotocography (CTG). One more recent trial compared Doppler examination of other fetal blood vessels (ductus venosus) with computerised CTG.The use of Doppler ultrasound of the umbilical artery in high-risk pregnancy was associated with fewer perinatal deaths (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.52 to 0.98, 16 studies, 10,225 babies, 1.2% versus 1.7 %, number needed to treat (NNT) = 203; 95% CI 103 to 4352, evidence graded moderate). The results for stillbirths were consistent with the overall rate of perinatal deaths, although there was no clear difference between groups for this outcome (RR 0.65, 95% CI 0.41 to 1.04; 15 studies, 9560 babies, evidence graded low). Where Doppler ultrasound was used, there were fewer inductions of labour (average RR 0.89, 95% CI 0.80 to 0.99, 10 studies, 5633 women, random-effects, evidence graded moderate) and fewer caesarean sections (RR 0.90, 95% CI 0.84 to 0.97, 14 studies, 7918 women, evidence graded moderate). There was no comparative long-term follow-up of babies exposed to Doppler ultrasound in pregnancy in women at increased risk of complications.No difference was found in operative vaginal births (RR 0.95, 95% CI 0.80 to 1.14, four studies, 2813 women), nor in Apgar scores less than seven at five minutes (RR 0.92, 95% CI 0.69 to 1.24, seven studies, 6321 babies, evidence graded low). Data for serious neonatal morbidity were not pooled due to high heterogeneity between the three studies that reported it (1098 babies) (evidence graded very low).The use of Doppler to evaluate early and late changes in ductus venosus in early fetal growth restriction was not associated with significant differences in any perinatal death after randomisation. However, there was an improvement in long-term neurological outcome in the cohort of babies in whom the trigger for delivery was either late changes in ductus venosus or abnormalities seen on computerised CTG. AUTHORS' CONCLUSIONS: Current evidence suggests that the use of Doppler ultrasound on the umbilical artery in high-risk pregnancies reduces the risk of perinatal deaths and may result in fewer obstetric interventions. The results should be interpreted with caution, as the evidence is not of high quality. Serial monitoring of Doppler changes in ductus venosus may be beneficial, but more studies of high quality with follow-up including neurological development are needed for evidence to be conclusive.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd007529.pub3

Cites

81 of 81 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

4 retracted

Show all 81 references

Research works printed but not linked: 16

  1. Marsal, 1991, Umbilical artery velocimetry is more effective than cardiotocography for surveillance of growth retarded fetuses, Journal of Perinatal Medicine, 19, 84
  2. Burke, 1992, Does Doppler ultrasound alter the management of high-risk pregnancy?, Journal of Perinatal Medicine, 20, 266
  3. Giles, 2000, The doppler assessment in multiple pregnancy study (damp) and metaanalyses of doppler and twins, American Journal of Obstetrics and Gynecology, 182, S17
  4. Nienhuis, 1995, Costs and effects of Doppler ultrasound measurements in suspected intrauterine growth retardation. A randomised clinical trial [thesis]
  5. Ruissen, 1992, Cost-effectiveness of a Doppler based policy of suspected intrauterine growth retardation - a randomised controlled trial, Journal of Maternal Fetal Investigation, 1, 126
  6. Nimrod, 1992, The utility of pulsed Doppler studies in the evaluation of postdate pregnancies, Journal of Maternal Fetal Investigation, 1, 127
  7. Williams, 2000, A randomized controlled clinical trial comparing non stress testing versus doppler velocimetry as a screening test in a high risk population [abstract], American Journal of Obstetrics and Gynecology, 182, S109
  8. Omtzigt, 1990, Clinical value of umbilical doppler velocimetry [thesis]
  9. Pearce, 1992, The application of uteroplacental waveforms to complicated pregnancies, 159
  10. Schneider, 1992, Doppler flow measurements as a screening method during pregnancy: is it worth the effort?, Journal of Maternal Fetal Investigation, 1, 125
  11. Almstrom, 1995, Umbilical artery velocimetry may influence clinical interpretation of intrapartum cardiotocograms, Acta Obstetricia et Gynecologica Scandinavica, 74, 526, 10.3109/00016349509024383 · DOI
  12. Fisk, 2001, Fetal growth restriction; small for gestational age, 197
  13. Nienhuis, 1995, Costs and effects of Doppler ultrasound measurements in suspected intrauterine growth retardation. A randomised clinical trial [thesis]
  14. Owen, 2001, Fetal assessment in the third trimester: fetal growth and biophysical methods
  15. The Nordic Cochrane Centre: The Cochrane Collaboration Review Manager (RevMan) 2008
  16. The Nordic Cochrane Centre, The Cochrane Collaboration Review Manager (RevMan) 2012

Cited by

See all 433

Metadata

Authors
Alfirevic, Z., Stampalija, T., & Gyte, G. M.
Venue
Cochrane Database of Systematic Reviews
Published
2013-11-12
Volume
6
Issue
11
Pages
CD007529-CD007529
ISSN
1361-6137 (ISSN-L)
OpenAlex
W2122930409
Cited by
433
References
81
Type
reference entry
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fetal and umbilical Doppler ultrasound in high-risk pregnancies. https://app.cochat.ai/papers/10.1002/14651858.cd007529.pub3
The paper
Alfirevic, Z., Stampalija, T., & Gyte, G. M. (2013). Fetal and umbilical Doppler ultrasound in high-risk pregnancies. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd007529.pub3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.