CoChat

High‐Resolution Microfocus X‐Ray Computed Tomography for 3D Surface Roughness Measurements of Additive Manufactured Porous Materials

Kerckhofs, Greet, Pyka, Grzegorz, Moesen, Maarten, Van Bael, Simon, Schrooten, Jan, Wevers, Martine · 2013 · Advanced Engineering Materials
Cited by 107

The DOI matches its Crossref record.

Abstract

Since commercially available profiling systems fail when determining the surface roughness of porous materials, we propose a novel protocol for surface roughness quantification of 3D additive manufactured porous structures based on high‐resolution microfocus X‐ray computed tomography (micro‐CT) images. It allows to non‐destructively assess the roughness of these porous materials at the outer surface as well as inside the structure. The noise in the images and the spatial image resolution both have a significant effect on the accuracy of the micro‐CT‐based roughness measurements. Comparing the roughness parameters of flat substrates determined both with commercially available (optical and contact) profiling systems and the micro‐CT‐based roughness measurement protocol shows that micro‐CT can be applied accurately and in a robust manner for surface roughness quantification of 3D additive manufactured porous materials with a micro‐scale roughness. Depending on the dimensions of the roughness, the micro‐CT acquisition parameters, i.e., frame averaging and spatial image resolution, need to be fine‐tuned. Submicron‐scale roughness can currently not be quantified.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adem.201200156

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kerckhofs, G., Pyka, G., Moesen, M., Van Bael, S., Schrooten, J., & Wevers, M.
Venue
Advanced Engineering Materials
Publisher
Wiley
Published
2012-10-12
Volume
15
Issue
3
Pages
153-158
ISSN
  • 1438-1656 (ISSN-L)
  • 1527-2648
OpenAlex
W1973638618
Cited by
107
References
0
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.