The DOI matches its Crossref record.
Gold Nanoparticle–Colloidal Carbon Nanosphere Hybrid Material: Preparation, Characterization, and Application for an Amplified Electrochemical Immunoassay
Abstract
A rapid microwave‐hydrothermal method has been developed to prepare monodisperse colloidal carbon nanospheres from glucose solution, and gold nanoparticles (AuNPs) are successfully assembled on the surface of the colloidal carbon nanospheres by a self‐assembly approach. The resulting AuNP/colloidal carbon nanosphere hybrid material (AuNP/C) has been characterized and is expected to offer a promising template for biomolecule immobilization and biosensor fabrication because of its satisfactory chemical stability and the good biocompatibility of AuNPs. Herein, as an example, it is demonstrated that the as‐prepared AuNP/C hybrid material can be conjugated with horseradish peroxidase‐labeled antibody (HRP‐Ab 2) to fabricate HRP‐Ab 2‐AuNP/C bioconjugates, which can then be used as a label for the sensitive detection of protein. The amperometric immunosensor fabricated on a carbon nanotube‐modified glass carbon electrode was very effective for antibody immobilization. The approach provided a linear response range between 0.01 and 250 ng mL−1 with a detection limit of 5.6 pg mL−1. The developed assay method was versatile, offered enhanced performances, and could be easily extended to other protein detection as well as DNA analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Titirici, M.-M., White, R. J., Brun, N., Budarin, V. L., Su, D. S., del Monte, F., Clark, J. H., & MacLachlan, M. J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00232f · Cited by 1,277
Molecular-based design and emerging applications of nanoporous carbon spheres
Liu, J., Wickramaratne, N. P., Qiao, S. Z., & Jaroniec, M. (2015) · Nature Materials · doi:10.1038/nmat4317 · Cited by 954
Titirici, M.-M., White, R. J., Falco, C., & Sevilla, M. (2012) · Energy & Environmental Science · doi:10.1039/c2ee21166a · Cited by 921
Microwave-Assisted Preparation of Inorganic Nanostructures in Liquid Phase
Zhu, Y.-J., & Chen, F. (2014) · Chemical Reviews · doi:10.1021/cr400366s · Cited by 912
Guo, S., & Wang, E. (2011) · Nano Today · doi:10.1016/j.nantod.2011.04.007 · Cited by 796
Electrochemical biosensors: perspective on functional nanomaterials for on-site analysis
Cho, I.-H., Kim, D. H., & Park, S. (2020) · Biomaterials Research · doi:10.1186/s40824-019-0181-y · Cited by 638
Du, D., Zou, Z., Shin, Y., Wang, J., Wu, H., Engelhard, M. H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac100036p · Cited by 448
Zhang, T., Wang, W., Zhang, D., Zhang, X., Ma, Y., Zhou, Y., & Qi, L. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200902104 · Cited by 365
Nanoengineering Carbon Spheres as Nanoreactors for Sustainable Energy Applications
Tian, H., Liang, J., & Liu, J. (2019) · Advanced Materials · doi:10.1002/adma.201903886 · Cited by 348
Du, D., Wang, L., Shao, Y., Wang, J., Engelhard, M. H., & Lin, Y. (2011) · Analytical Chemistry · doi:10.1021/ac101715s · Cited by 306
Dong, F., Wang, H., & Wu, Z. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp9049654 · Cited by 287
Biomolecule-nanoparticle hybrids for electrochemical biosensors
GUO, S., & DONG, S. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.10.014 · Cited by 274
Growth of Metal–Metal Oxide Nanostructures on Freestanding Graphene Paper for Flexible Biosensors
Xiao, F., Li, Y., Zan, X., Liao, K., Xu, R., & Duan, H. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200191 · Cited by 273
Wang, S., Li, W.-C., Hao, G.-P., Hao, Y., Sun, Q., Zhang, X.-Q., & Lu, A.-H. (2011) · Journal of the American Chemical Society · doi:10.1021/ja206333w · Cited by 253
Metadata
- Authors
- Cui, R., Liu, C., Shen, J., Gao, D., Zhu, J., & Chen, H.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2008-08-06
- Volume
- 18
- Issue
- 15
- Pages
- 2197-2204
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2084078153
- Cited by
- 220
- References
- 0
- FWCI
- 18.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.