Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 306

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Functionalized Graphene Oxide as a Nanocarrier in a Multienzyme Labeling Amplification Strategy for Ultrasensitive Electrochemical Immunoassay of Phosphorylated p53 (S392)

Du, Dan, Wang, Limin, Shao, Yuyan, Wang, Jun, Engelhard, Mark H., Lin, Yuehe·2011·Analytical Chemistry

Abstract

P53 phosphorylation plays an important role in many biological processes and might be used as a potential biomarker in clinical diagnoses. We report a new electrochemical immunosensor for ultrasensitive detection of phosphorylated p53 at Ser392 (phospho-p53(392)) based on graphene oxide (GO) as a nanocarrier in a multienzyme amplification strategy. Greatly enhanced sensitivity was achieved by using the bioconjugates featuring horseradish peroxidase (HRP) and p53(392) signal antibody (p53(392)Ab(2)) linked to functionalized GO (HRP-p53(392)Ab(2)-GO) at a high ratio of HRP/p53(392)Ab(2). After a sandwich immunoreaction, the HRP-p53(392)Ab(2)-GO captured onto the electrode surface produced an amplified electrocatalytic response by the reduction of enzymatically oxidized thionine in the presence of hydrogen peroxide. The increase of response current was proportional to the phospho-p53(392) concentration in the range of 0.02-2 nM with the detection limit of 0.01 nM, which was 10-fold lower than that of the traditional sandwich electrochemical measurement for p53(392). The amplified immunoassay developed in this work shows acceptable stability and reproducibility, and the assay results for phospho-p53(392) spiked in human plasma also show good recovery (92-103.8%). This simple and low-cost immunosensor shows great promise for detection of other phosphorylated proteins and clinical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac101715s

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 306

Metadata

Authors
Du, D., Wang, L., Shao, Y., Wang, J., Engelhard, M. H., & Lin, Y.
Venue
Analytical Chemistry
Published
2011-01-06
Volume
83
Issue
3
Pages
746-752
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2006487505
Cited by
306
References
3
FWCI
32.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Functionalized Graphene Oxide as a Nanocarrier in a Multienzyme Labeling Amplification Strategy for Ultrasensitive Electrochemical Immunoassay of Phosphorylated p53 (S392). https://app.cochat.ai/papers/10.1021/ac101715s
The paper
Du, D., Wang, L., Shao, Y., Wang, J., Engelhard, M. H., & Lin, Y. (2011). Functionalized Graphene Oxide as a Nanocarrier in a Multienzyme Labeling Amplification Strategy for Ultrasensitive Electrochemical Immunoassay of Phosphorylated p53 (S392). Analytical Chemistry. https://doi.org/10.1021/ac101715s

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.