Thin‐Wall Assembled SnO2 Fibers Functionalized by Catalytic Pt Nanoparticles and their Superior Exhaled‐Breath‐Sensing Properties for the Diagnosis of Diabetes
Abstract
Hierarchical SnO 2 fibers assembled from wrinkled thin tubes are synthesized by controlling the microphase separation between tin precursors and polymers, by varying flow rates during electrospinning and a subsequent heat treatment. The inner and outer SnO 2 tubes have a number of elongated open pores ranging from 10 nm to 500 nm in length along the fiber direction, enabling fast transport of gas molecules to the entire thin‐walled sensing layers. These features admit exhaled gases such as acetone and toluene, which are markers used for the diagnosis of diabetes and lung cancer. The open tubular structures facilitated the uniform coating of catalytic Pt nanoparticles onto the inner SnO 2 layers. Highly porous SnO 2 fibers synthesized at a high flow rate show five‐fold higher acetone responses than densely packed SnO 2 fibers synthesized at a low flow rate. Interestingly, thin‐wall assembled SnO 2 fibers functionalized by Pt particles exhibit a dramatically shortened gas response time compared to that of un‐doped SnO 2 fibers, even at low acetone concentrations. Moreover, Pt‐decorated SnO 2 fibers significantly enhance toluene response. These results demonstrate the novel and practical feasibility of thin‐wall assembled metal oxide based breath sensors for the accurate diagnosis of diabetes and potential detection of lung cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conduction Model of Metal Oxide Gas Sensors
Barsan, N., & Weimar, U. (2001) · Journal of Electroceramics · doi:10.1023/a:1014405811371 · Cited by 2,721
New approaches for improving semiconductor gas sensors
Yamazoe, N. (1991) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(91)80213-4 · Cited by 1,796
Application of conducting polymers to biosensors
Gerard, M. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00312-8 · Cited by 1,652
Micro- and Nanostructured Surface Morphology on Electrospun Polymer Fibers
Megelski, S., Stephens, J. S., Chase, D. B., & Rabolt, J. F. (2002) · Macromolecules · doi:10.1021/ma020444a · Cited by 1,323
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Nanostructured Fibers via Electrospinning
Bognitzki, M., Czado, W., Frese, T., Schaper, A., Hellwig, M., Steinhart, M., Greiner, A., & Wendorff, J. H. (2001) · Advanced Materials · doi:10.1002/1521-4095(200101)13:1<70::aid-adma70>3.0.co;2-h · Cited by 1,236
Oxide Materials for Development of Integrated Gas Sensors—A Comprehensive Review
Eranna, G., Joshi, B. C., Runthala, D. P., & Gupta, R. P. (2004) · Critical Reviews in Solid State and Materials Sciences · doi:10.1080/10408430490888977 · Cited by 1,072
Casper, C. L., Stephens, J. S., Tassi, N. G., Chase, D. B., & Rabolt, J. F. (2004) · Macromolecules · doi:10.1021/ma0351975 · Cited by 1,006
Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Electrostatic spinning of acrylic microfibers
Baumgarten, P. K. (1971) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(71)90241-4 · Cited by 816
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Righettoni, M., Tricoli, A., & Pratsinis, S. E. (2010) · Analytical Chemistry · doi:10.1021/ac902695n · Cited by 630
Deng, C., ZHANG, J., Xiang, Y., Zhang, W., & ZHANG, X. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.013 · Cited by 590
Electrospinning: A Simple and Versatile Technique for Producing Ceramic Nanofibers and Nanotubes
Li, D., McCann, J. T., Xia, Y., & Marquez, M. (2006) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2006.00989.x · Cited by 499
Poli, D., Carbognani, P., Corradi, M., Goldoni, M., Acampa, O., Balbi, B., Bianchi, L., Rusca, M., & Mutti, A. (2005) · Respiratory Research · doi:10.1186/1465-9921-6-71 · Cited by 415
Yang, D., Kamienchick, I., Youn, D. Y., Rothschild, A., & Kim, I. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201001251 · Cited by 404
Self-citationSynthesis of monodisperse Au, Pt, Pd, Ru and Ir nanoparticles in ethylene glycol
Bonet, F., Delmas, V, Grugeon, S., Herrera Urbina, R., Silvert, P.-Y., & Tekaia-Elhsissen, K. (1999) · Nanostructured Materials · doi:10.1016/s0965-9773(99)00419-5 · Cited by 363
Dai, Y., Liu, W., Formo, E., Sun, Y., & Xia, Y. (2011) · Polymers for Advanced Technologies · doi:10.1002/pat.1839 · Cited by 359
Ferroelectric WO3 Nanoparticles for Acetone Selective Detection
Wang, L., Teleki, A., Pratsinis, S. E., & Gouma, P. I. (2008) · Chemistry of Materials · doi:10.1021/cm800761e · Cited by 357
A review of breath analysis for diagnosis of human health
Kim, K.-H., Jahan, S. A., & Kabir, E. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.09.013 · Cited by 345
Inorganic Hollow Nanotube Aerogels by Atomic Layer Deposition onto Native Nanocellulose Templates
Korhonen, J. T., Hiekkataipale, P., Malm, J., Karppinen, M., Ikkala, O., & Ras, R. H. A. (2011) · ACS Nano · doi:10.1021/nn200108s · Cited by 326
Morphology of Porous and Wrinkled Fibers of Polystyrene Electrospun from Dimethylformamide
Pai, C.-L., Boyce, M. C., & Rutledge, G. C. (2009) · Macromolecules · doi:10.1021/ma802529h · Cited by 260
Diskin, A. M., pan l, P., & Smith, D. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/308 · Cited by 237
Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath
Španěl, P., & Smith, D. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523843 · Cited by 229
Fabrication of Ultrafine Metal-Oxide-Decorated Carbon Nanofibers for DMMP Sensor Application
Lee, J. S., Kwon, O. S., Park, S. J., Park, E. Y., You, S. A., Yoon, H., & Jang, J. (2011) · ACS Nano · doi:10.1021/nn202471f · Cited by 219
Self-citationHighly aligned SnO2 nanorods on graphene sheets for gas sensors
Zhang, Z., Zou, R., Song, G., Yu, L., Chen, Z., & Hu, J. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm12987b · Cited by 213
O'Neill, H. J., Gordon, S. M., O'Neill, M. H., Gibbons, R. D., & Szidon, J. P. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.8.1613 · Cited by 207
Miyauchi, Y., Ding, B., & Shiratori, S. (2006) · Nanotechnology · doi:10.1088/0957-4484/17/20/019 · Cited by 188
Fleischer, M., Simon, E., Rumpel, E., Ulmer, H., Harbeck, M., Wandel, M., Fietzek, C., Weimar, U., & Meixner, H. (2002) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(01)01056-5 · Cited by 169
Application of semiconductor gas sensors for medical diagnostics
Ryabtsev, S. V., Владимирович, Ш. А., Лукин, А. Н., & Domashevskaya, E. P. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00162-8 · Cited by 164
Single β-AgVO3 Nanowire H2S Sensor
Mai, L., Xu, L., Gao, Q., Han, C., Hu, B., & Pi, Y. (2010) · Nano Letters · doi:10.1021/nl1013184 · Cited by 157
Nayani, K., Katepalli, H., Sharma, C. S., Sharma, A., Patil, S., & Venkataraghavan, R. (2011) · Industrial & Engineering Chemistry Research · doi:10.1021/ie2009229 · Cited by 156
A novel method for diabetes diagnosis based on electronic nose
Wang, P., Yi, T., Haibao, X., & Farong, S. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00059-6 · Cited by 146
Analysis of diabetic patient's breath with conducting polymer sensor array
Yu, J.-B., Byun, H., So, M.-S., & Huh, J.-S. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.01.040 · Cited by 146
Breath analysis in critically ill patients: potential and limitations
Schubert, J. K., Miekisch, W., Geiger, K. K., & Nöldge‐Schomburg, G. (2004) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.4.5.619 · Cited by 110
Analytical performance of glucometers used for routine glucose self-monitoring of diabetic patients
Solnica, B., Naskalski, J. W., & Sieradzki, J. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00079-2 · Cited by 105
Peng, M., Li, D., Shen, L. H., Chen, Y., Zheng, Q., & Wang, H. (2006) · Langmuir · doi:10.1021/la061154g · Cited by 104
WO3 nanocrystals: Synthesis and application in highly sensitive detection of acetone
Shi, J., Hu, G., Sun, Y., Geng, M., Wu, J., Liu, Y., Ge, M., Tao, J., Cao, M., & Dai, N. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.02.047 · Cited by 101
A novel method to fabricate silica nanotubes based on phase separation effect
Wang, W., Zhou, J., Zhang, S., Song, J., Duan, H., Zhou, M. X., Gong, C., Bao, Z., Lu, B., Li, X., et al. (2010) · Journal of Materials Chemistry · doi:10.1039/c0jm02120b · Cited by 86
Measurement of Ammonia in Human Breath with a Liquid-Film Conductivity Sensor
Toda, K., Li, J., & Dasgupta, P. Κ. (2006) · Analytical Chemistry · doi:10.1021/ac060965m · Cited by 82
Metal Oxide-Based Monolithic Complementary Metal Oxide Semiconductor Gas Sensor Microsystem
Gräf, M., Barrettino, D., Taschini, S., et al. (2004) · Analytical Chemistry · doi:10.1021/ac035432h · Cited by 79
Han, S. O., Son, W. K., Cho, D., Youk, J. H., & Park, W. H. (2004) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2004.04.015 · Cited by 65
Cited by
Highly sensitive and selective gas sensors using p-type oxide semiconductors: Overview
Kim, H.-J., & Lee, J.-H. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.11.005 · Cited by 2,258
Self-citationRecent Progress on the Development of Chemosensors for Gases
Zhou, X., Lee, S., Xu, Z., & Yoon, J. (2015) · Chemical Reviews · doi:10.1021/cr500567r · Cited by 777
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Nanoparticles meet electrospinning: recent advances and future prospects
Zhang, C.-L., & Yu, S.-H. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60426h · Cited by 665
2D Materials for Gas Sensing Applications: A Review on Graphene Oxide, MoS2, WS2 and Phosphorene
Donarelli, M., & Ottaviano, L. (2018) · Sensors · doi:10.3390/s18113638 · Cited by 644
Metadata
- Authors
- Shin, J., Choi, S., Lee, I., Youn, D., Park, C. O., Lee, J., Tuller, H. L., & Kim, I.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2012-12-13
- Volume
- 23
- Issue
- 19
- Pages
- 2357-2367
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2039386261
- Cited by
- 391
- References
- 42
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.