Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 334

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Miniaturized Battery‐Free Wireless Systems for Wearable Pulse Oximetry

Open access
Kim, Jeonghyun, Gutruf, Philipp, Chiarelli, Antonio M., Heo, Seung Yun, Cho, Kyoungyeon, Xie, Zhaoqian, Banks, Anthony, Han, Seungyoung, Jang, Kyung‐In, Lee, Jung Woo, Lee, Kyu‐Tae, Feng, Xue, Huang, Yonggang, Fabiani, Monica, Gratton, Gabriele, Paik, Ungyu, Rogers, John A.·2017·Advanced Functional Materials

Abstract

Development of unconventional technologies for wireless collection and analysis of quantitative, clinically relevant information on physiological status is of growing interest. Soft, biocompatible systems are widely regarded as important because they facilitate mounting on external (e.g., skin) and internal (e.g., heart and brain) surfaces of the body. Ultraminiaturized, lightweight, and battery‐free devices have the potential to establish complementary options in biointegration, where chronic interfaces (i.e., months) are possible on hard surfaces such as the fingernails and the teeth, with negligible risk for irritation or discomfort. Here, the authors report materials and device concepts for flexible platforms that incorporate advanced optoelectronic functionality for applications in wireless capture and transmission of photoplethysmograms, including quantitative information on blood oxygenation, heart rate, and heart rate variability. Specifically, reflectance pulse oximetry in conjunction with near‐field communication capabilities enables operation in thin, miniaturized flexible devices. Studies of the material aspects associated with the body interface, together with investigations of the radio frequency characteristics, the optoelectronic data acquisition approaches, and the analysis methods capture all of the relevant engineering considerations. Demonstrations of operation on various locations of the body and quantitative comparisons to clinical gold standards establish the versatility and the measurement accuracy of these systems, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.201604373

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 334

Metadata

Authors
Kim, J., Gutruf, P., Chiarelli, A. M., Heo, S. Y., Cho, K., Xie, Z., Banks, A., Han, S., Jang, K., Lee, J. W., Lee, K., Feng, X., Huang, Y., Fabiani, M., Gratton, G., Paik, U., & Rogers, J. A.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2016-11-25
Volume
27
Issue
1
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2555752707
Cited by
334
References
19
FWCI
14.13
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Miniaturized Battery‐Free Wireless Systems for Wearable Pulse Oximetry. https://app.cochat.ai/papers/10.1002/adfm.201604373
The paper
Kim, J., Gutruf, P., Chiarelli, A. M., Heo, S. Y., Cho, K., Xie, Z., Banks, A., Han, S., Jang, K., Lee, J. W., Lee, K., Feng, X., Huang, Y., Fabiani, M., Gratton, G., Paik, U., & Rogers, J. A. (2017). Miniaturized Battery‐Free Wireless Systems for Wearable Pulse Oximetry. Advanced Functional Materials. https://doi.org/10.1002/adfm.201604373

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.