In Vivo Subcutaneous Thermal Video Recording by Supersensitive Infrared Nanothermometers
Abstract
Some of the old and unrealizable dreams of biomedicine have become possible thanks to the appearance of novel advanced materials such as luminescent nanothermometers, nanoparticles capable of providing a contactless thermal reading through their light emission properties. Luminescent nanothermometers have already been demonstrated to be capable of in vivo subcutaneous punctual thermal reading but their real application as diagnosis tools still requires demonstrating their actual capacity for the acquisition of in vivo, time‐resolved subcutaneous thermal images. The transfer from 1D to 2D subcutaneous thermal sensing is blocked in the last years mainly due to the lack of high sensitivity luminescent nanothermometers operating in the infrared biological windows. This work demonstrates how core/shell engineering, in combination with selective rare earth doping, can be used to develop supersensitive infrared luminescent nanothermometers. Erbium, thulium, and ytterbium core–shell LaF 3 nanoparticles, operating within the biological windows, provide thermal sensitivities as large as 5% °C−1. This “record” sensitivity has allowed for the final acquisition of subcutaneous thermal videos of a living animal. Subsequent analysis of thermal videos allows for an unequivocal determination of intrinsic properties of subcutaneous tissues, opening the venue to the development of novel thermal imaging‐based diagnosis tools.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
Deep optical imaging of tissue using the second and third near-infrared spectral windows
Sordillo, L. A., Pu, Y., Pratavieira, S., Budansky, Y., & Alfano, R. R. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.5.056004 · Cited by 407
Cited by
Runowski, M., Shyichuk, A., Tymiński, A., Grzyb, T., Lavín, V., & Lis, S. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b02853 · Cited by 318
Suta, M., & Meijerink, A. (2020) · Advanced Theory and Simulations · doi:10.1002/adts.202000176 · Cited by 306
Zhen, X., Xie, C., & Pu, K. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201712550 · Cited by 284
Tang, Y., Li, Y., Lu, X., Hu, X., Zhao, H., Hu, W., Lu, F., Fan, Q., & Huang, W. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807376 · Cited by 96
Metadata
- Authors
- Ximendes, E. C., Rocha, U., Sales, T. O., Fernández, N., Sanz‐Rodríguez, F., Martín, I. R., Jacinto, C., & Jaque, D.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2017-08-14
- Volume
- 27
- Issue
- 38
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2747585637
- Cited by
- 210
- References
- 3
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Subcutaneous Thermal Video Recording by Supersensitive Infrared Nanothermometers. https://app.cochat.ai/papers/10.1002/adfm.201702249
- The paper
- Ximendes, E. C., Rocha, U., Sales, T. O., Fernández, N., Sanz‐Rodríguez, F., Martín, I. R., Jacinto, C., & Jaque, D. (2017). In Vivo Subcutaneous Thermal Video Recording by Supersensitive Infrared Nanothermometers. Advanced Functional Materials. https://doi.org/10.1002/adfm.201702249
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.