Highly Efficient In Vivo Cancer Therapy by an Implantable Magnet Triboelectric Nanogenerator
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this work, a nanogenerator‐controlled drug delivery system (DDS) for use in cancer therapy is successfully established. A new magnet triboelectric nanogenerator (MTENG) is fabricated that can guarantee the contact and detach cycle between the two friction layers and effectively increase the TENG output, up to 70 V after implantation. Using a special structural design, without the commonly used spacer, this contacting‐mode MTENG can ensure a high and consistent electricity output after encapsulation and implantation. Doxorubicin‐(DOX‐) loaded red blood cells (RBCs) are employed as the anti‐tumor DDS in this study. After DOX loading, the RBC membranes are stable and the self‐release is very slow. However, upon electric stimulation from the MTENG, the release of DOX is remarkably increased, and falls back to normal again after the stimulation. Thus a controllable DDS is established. The MTENG‐controllable DDS achieves an outstanding killing of carcinomatous cells both in vitro and in vivo at a low DOX dosage. These results demonstrate a prominent therapeutic effect of the MTENG‐controlled DDS for cancer therapy, which is highly promising for application in the clinic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spheroid-based drug screen: Considerations and practical approach
Friedrich, J., Seidel, C., Ebner, R., & Kunz-Schughart, L. A. (2009) · Nature Protocols · doi:10.1038/nprot.2008.226 · Cited by 1,742
In Vivo Self-Powered Wireless Cardiac Monitoring via Implantable Triboelectric Nanogenerator
Zheng, Q., Zhang, H., Shi, B., Xue, X., Liu, Z., Jin, Y., Ma, Y., Zou, Y., Wang, X., An, Z., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b02693 · Cited by 449
Self-citationMuscle‐Driven In Vivo Nanogenerator
Li, Z., Zhu, G., Yang, R., Wang, A. C., & Wang, Z. L. (2010) · Advanced Materials · doi:10.1002/adma.200904355 · Cited by 441
Self-citationGraphene Tribotronics for Electronic Skin and Touch Screen Applications
Khan, U., Kim, T., Ryu, H., Seung, W., & Kim, S. (2017) · Advanced Materials · doi:10.1002/adma.201603544 · Cited by 270
Rajamathi, C. R., Gupta, U., Kumar, N., Yang, H., Sun, Y., Süβ, V., Shekhar, C., Schmidt, M., Yan, B., Parkin, S., et al. (2016) · arXiv · doi:10.48550/arxiv.1608.03783 · Cited by 3
Cited by
Accelerated Skin Wound Healing by Electrical Stimulation
Luo, R., Dai, J., Zhang, J., & Li, Z. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100557 · Cited by 510
Self-citationProgress in TENG technology—A journey from energy harvesting to nanoenergy and nanosystem
Zhu, J., Zhu, M., Shi, Q., Wen, F., Liu, L., Dong, B., Haroun, A., Yang, Y., Vachon, P., Guo, X., et al. (2020) · EcoMat · doi:10.1002/eom2.12058 · Cited by 370
Emerging Implantable Energy Harvesters and Self-Powered Implantable Medical Electronics
Jiang, D., Shi, B., Ouyang, H., Fan, Y., Wang, Z. L., & Li, Z. (2020) · ACS Nano · doi:10.1021/acsnano.9b08268 · Cited by 343
Self-citationWang, C., He, T., Zhou, H., Zhang, Z., & Lee, C. (2023) · Bioelectronic Medicine · doi:10.1186/s42234-023-00118-1 · Cited by 295
“Meanwhile, the research on implantable devices also makes high requirements for materials selection, structure design, system integration, power supply, and biological safety (Jiang et al. 2018; Wang et al. 2019; Yao et al. 2022; Zhao et al. 2019).”
BackgroundSelf-citationZhu, M., Yi, Z., Yang, B., & Lee, C. (2021) · Nano Today · doi:10.1016/j.nantod.2020.101016 · Cited by 295
Metadata
- Authors
- Zhao, C., Feng, H., Zhang, L., Li, Z., Zou, Y., Tan, P., Ouyang, H., Jiang, D., Yu, M., Wang, C., Li, H., Xu, L., Wei, W., & Li, Z.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-01-28
- Volume
- 29
- Issue
- 41
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2912281538
- Cited by
- 131
- References
- 5
- FWCI
- 6.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.