A Diagnostic and Therapeutic Hydrogel to Promote Vascularization via Blood Sugar Reduction for Wound Healing
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Chronic hyperglycemic damage is a major problem that undermines diabetic wound healing. By combining treatment and diagnosis together, blood glucose concentration can be monitored real‐time through medical imaging devices and precise interventions can be carried out at the right time to promote diabetic wound repair. In this study, an injectable self‐healing hyaluronic acid hydrogel is constructed using Schiff base reaction, and nanoenzymes (GOx‐MnO 2) synthesized by condensation reaction, along with vascular endothelial growth factor (VEGF)‐nanobubbles produced by double emulsification method, are loaded into the hydrogel, thus constructing an innovative diagnostic and therapeutic hydrogel system (US@GOx@VEGF hydrogel, UGV hydrogel). While monitoring glucose concentration in real‐time, the system delivers VEGF through ultrasound in a precise and noninvasive way to deplete glucose. The UGV hydrogel integrates both processes of diagnosis and treatment, effectively releases VEGF through blasts triggered by ultrasound. Apart from this, this new trauma patch is capable of monitoring Mn 2+ values ranging from 0.5 m to 7.8 × 10−3 m and glucose levels from 100 × 10−3 to 3 × 10−3 m, through magnetic resonance imaging. In summary, the hydrogel realizes real‐time monitoring of glucose level, maintains glucose homeostasis through noninvasive intervention, and rapidly promotes the repair of diabetic skin defects, opening up a new path for chronic wound management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxidative stress and diabetic complications
Giacco, F., & Brownlee, M. (2010) · Circulation Research · doi:10.1161/circresaha.110.223545 · Cited by 5,461
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Miniaturized Needle Array‐Mediated Drug Delivery Accelerates Wound Healing
Samandari, M., Aghabaglou, F., Nuutila, K., Derakhshandeh, H., Zhang, Y., Endo, Y., Harris, S., Barnum, L., Kreikemeier‐Bower, C., Arab‐Tehrany, E., et al. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001800 · Cited by 47
Self-citation
Cited by
Zhou, X., Ning, X., Chen, Y., Chang, H., Lu, D., Pei, D., Geng, Z., Zeng, Z., Guo, C., Huang, J., et al. (2023) · ACS Materials Letters · doi:10.1021/acsmaterialslett.3c00925 · Cited by 127
Tough adhesion enhancing strategies for injectable hydrogel adhesives in biomedical applications
Ouyang, C., Yu, H., Wang, L., Ni, Z., Liu, X., Shen, D., Yang, J., Shi, K., & Wang, H. (2023) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2023.102982 · Cited by 82
Liu, Y., Zhao, Y., Guo, S., Qin, D., Yan, J., Cheng, H., Zhou, J., Ren, J., Sun, L., Peng, H., et al. (2024) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2024.122656 · Cited by 54
Metadata
- Authors
- Han, X., Chen, S., Cai, Z., Zhu, Y., Yi, W., Guan, M., Liao, B., Zhang, Y., Shen, J., Cui, W., & Bai, D.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2023-01-15
- Volume
- 33
- Issue
- 14
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W4316362731
- Cited by
- 90
- References
- 4
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.