Non-invasive, transdermal, path-selective and specific glucose monitoring via a graphene-based platform
Open accessAbstract
Currently, there is no available needle-free approach for diabetics to monitor glucose levels in the interstitial fluid. Here, we report a path-selective, non-invasive, transdermal glucose monitoring system based on a miniaturized pixel array platform (realized either by graphene-based thin-film technology, or screen-printing). The system samples glucose from the interstitial fluid via electroosmotic extraction through individual, privileged, follicular pathways in the skin, accessible via the pixels of the array. A proof of principle using mammalian skin ex vivo is demonstrated for specific and 'quantized' glucose extraction/detection via follicular pathways, and across the hypo- to hyper-glycaemic range in humans. Furthermore, the quantification of follicular and non-follicular glucose extraction fluxes is clearly shown. In vivo continuous monitoring of interstitial fluid-borne glucose with the pixel array was able to track blood sugar in healthy human subjects. This approach paves the way to clinically relevant glucose detection in diabetics without the need for invasive, finger-stick blood sampling.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Hyaluronic acid was employed to increase osmotic pressure and drive more glucose toward the electrode.
“They employed hyaluronic acid to increase osmotic pressure and drive more glucose toward the electrode.”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [169]
A transdermal patch consisting of graphene microarrays has been developed to monitor ISF glucose through follicles.
“So far, a transdermal patch consisting of graphene microarrays has been developed to monitor ISF glucose through follicles [169].”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [169]
6G end-to-end delay, radio delay and processing requirements are 1 ms, 10 ns and 10 ns respectively to provide real-time communication.
“The end-to-end delay, radio delay and processing requirements are 1 ms, 10 ns and 10 ns respectively to provide real-time communication [2], [22].”
From 6G Communication Technology: A Vision on Intelligent Healthcare (2021) · cites this paper as [22]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Wild, S., Roglic, G., Green, A., Sicree, R., & King, H. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1047 · Cited by 15,297 · see citing works
Roll-to-roll production of 30-inch graphene films for transparent electrodes
Bae, S., Kim, H., Lee, Y., Xu, X., Park, J.-S., Zheng, Y., Balakrishnan, J., Lei, T., Kim, H. R., Song, Y. I., et al. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.132 · Cited by 8,158 · see citing works
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · see citing works
Shrivastava, A., & Gupta, V. B. (2011) · Chronicles of young scientists · doi:10.4103/2229-5186.79345 · Cited by 3,237 · see citing works
Transfer of Large-Area Graphene Films for High-Performance Transparent Conductive Electrodes
Li, X., Zhu, Y., Cai, W., Borysiak, M. D., Han, B., Chen, D., Piner, R. D., Colombo, L., & Ruoff, R. S. (2009) · Nano Letters · doi:10.1021/nl902623y · Cited by 3,086 · see citing works
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802 · see citing works
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700 · see citing works
Schmook, F. P., Meingassner, J. G., & Billich, A. (2001) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(00)00665-7 · Cited by 529 · see citing works
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513 · see citing works
Variations of Hair Follicle Size and Distribution in Different Body Sites
Otberg, N., Richter, H., Schaefer, H. E., Blume‐Peytavi, U., Sterry, W., & Lademann, J. M. (2004) · Journal of Investigative Dermatology · doi:10.1046/j.0022-202x.2003.22110.x · Cited by 448 · see citing works
Boyne, M. S., Silver, D. M., Kaplan, J., & Saudek, C. D. (2003) · Diabetes · doi:10.2337/diabetes.52.11.2790 · Cited by 404 · see citing works
Quantitative 1H NMR. Development and Potential of an Analytical Method: An Update
Pauli, G. F., Gödecke, T., Jaki, B. U., et al. (2012) · Journal of Natural Products · doi:10.1021/np200993k · Cited by 372 · see citing works
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294 · see citing works
Noninvasive Glucose Monitoring
Tamada, J. A., Garg, S. K., Jovanovič, L., Pitzer, K. R., Fermi, S. J., & Potts, R. O. (1999) · JAMA · doi:10.1001/jama.282.19.1839 · Cited by 281 · see citing works
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267 · see citing works
Ag/AgCl microelectrodes with improved stability for microfluidics
Polk, B. J., Stelzenmuller, A., Mijares, G. I., et al. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.03.121 · Cited by 247 · see citing works
Glucose monitoring by reverse iontophoresis
Potts, R. O., Tamada, J. A., & Tierney, M. J. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.210 · Cited by 244 · see citing works
Noninvasive glucose monitoring using saliva nano-biosensor
Zhang, W., Du, Y., & Wang, M. L. (2015) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2015.02.002 · Cited by 232 · see citing works
Can Interstitial Glucose Assessment Replace Blood Glucose Measurements?
Rebrin, K., & Steil, G. M. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050194332 · Cited by 220 · see citing works
Time Lag of Glucose From Intravascular to Interstitial Compartment in Humans
Basu, A., Dube, S., Slama, M. Q., Errazuriz, I., Amezcua, J. C., Kudva, Y. C., Peyser, T. A., Carter, R. E., Cobelli, C., & Basu, R. (2013) · Diabetes · doi:10.2337/db13-1132 · Cited by 208 · see citing works
Garg, S. K., Potts, R. O., Ackerman, N. R., Fermi, S. J., Tamada, J. A., & Chase, H. P. (1999) · Diabetes Care · doi:10.2337/diacare.22.10.1708 · Cited by 200 · see citing works
Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011) · Analytical Chemistry · doi:10.1021/ac201700c · Cited by 185 · see citing works
He, D., Garg, S., & Waite, T. D. (2012) · Langmuir · doi:10.1021/la300929g · Cited by 174 · see citing works
Contributions of Electromigration and Electroosmosis to Iontophoretic Drug Delivery
Marro, D., Kalia, Y. N., Delgado-Charro, M. B., et al. (2001) · Pharmaceutical Research · doi:10.1023/a:1013318412527 · Cited by 149 · see citing works
Sieg, A., Guy, R. H., & Delgado-Charro, M. B. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.044792 · Cited by 82 · see citing works
Self-citationYeh, S.-J., Hanna, C. F., & Khalil, O. S. (2003) · Clinical Chemistry · doi:10.1373/49.6.924 · Cited by 79 · see citing works
Continuous Glucose Monitoring: The Future of Diabetes Management
Burge, M. R., Mitchell, S., Sawyer, A. M., & Schade, D. S. (2008) · Diabetes Spectrum · doi:10.2337/diaspect.21.2.112 · Cited by 66 · see citing works
McGarraugh, G. V., Brazg, R., & Weinstein, R. L. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500114 · Cited by 57 · see citing works
Glucose detection in human sweat using an electronic nose
Olarte, O., Chilo, J., Pelegrí-Sebastiá, J., Barbé, K., & Moer, W. V. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609787 · Cited by 49 · see citing works
Visualization and Quantitation of Iontophoretic Pathways Using Confocal Microscopy
Turner, N. G., & Guy, R. H. (1998) · Journal of Investigative Dermatology Symposium Proceedings · doi:10.1038/jidsymp.1998.28 · Cited by 49 · see citing works
Self-citationYu, S., Li, D., Chong, H., Sun, C., Yu, H., & Xu, K. (2013) · Biomedical Optics Express · doi:10.1364/boe.5.000275 · Cited by 44 · see citing works
Visualization and Analysis of Electroosmotic Flow in Hairless Mouse Skin
Bath, B. D., White, H. S., & Scott, E. R. (2000) · Pharmaceutical Research · doi:10.1023/a:1007589306661 · Cited by 42 · see citing works
Analysis: PENDRA: The Once and Future Noninvasive Continuous Glucose Monitoring Device?
Weinzimer, S. A. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/1520915041706018 · Cited by 37 · see citing works
Mamkin, I., Ten, S., Bhandari, S., & Ramchandani, N. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200520 · Cited by 33 · see citing works
Glucose Monitoring in Acute Care: Technologies on the Horizon
Torjman, M. C., Dalal, N., & Goldberg, M. E. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200202 · Cited by 18 · see citing works
Alshammari, A., Posner, M. G., Upadhyay, A. K., et al. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b05453 · Cited by 15 · see citing works
FDA Panel Approves Cygnus's Noninvasive GlucoWatch™
Sage, B. H. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091599316829 · Cited by 4 · see citing works
Flagged first, then by citations
Research works printed but not linked: 5
- Chemical and Biological Microsensors: Applications in Fluid Media (Wiley-ISTE, London, 2009).
- ICH Harmonised Tripartite Guideline (International Conference On Harmonisation Of Technical Requirements For Registration Of Pharmaceuticals For Human Use, Geneva, 2005).
- Electrochemical Sensor Analysis (Elsevier Science, Amsterdam, 2007).
- Bioelectrochemistry: Fundamentals, Applications and Recent Developments (Wiley, Hoboken, 2011).
- Petrucci, R. H. General Chemistry: Principles & Modern Applications, 9 edn. (Prentice Hall, Upper Saddle River, 2007).
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · see citing works
Wearable chemical sensors for biomarker discovery in the omics era
Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, K., Wang, J., & Gao, W. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00439-w · Cited by 613 · see citing works
Integrated textile sensor patch for real-time and multiplex sweat analysis
He, W., Wang, C., Wang, H., Jian, M., Lu, W., Liang, X., Zhang, X., Yang, F., & Zhang, Y. (2019) · Science Advances · doi:10.1126/sciadv.aax0649 · Cited by 564 · see citing works
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535 · see citing works
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481 · see citing works
Wang, M., Luo, Y., Wang, T., Wan, C., Pan, L., Pan, S., He, K., Neo, A., & Chen, X. (2021) · Advanced Materials · doi:10.1002/adma.202003014 · Cited by 451 · see citing works
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453 · see citing works
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442 · see citing works
Lab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310 · see citing works
Teymourian, H., Moonla, C., Tehrani, F., Vargas, E., Aghavali, R., Barfidokht, A., Tangkuaram, T., Mercier, P. P., Dassau, E., & Wang, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05109 · Cited by 278 · see citing works
Li, X., Huang, X., Mo, J., Wang, H., Huang, Q., Yang, C., Zhang, T., Chen, H., Hang, T., Liu, F., et al. (2021) · Advanced Science · doi:10.1002/advs.202100827 · Cited by 250 · see citing works
Wearable and Mobile Sensors for Personalized Nutrition
Sempionatto, J. R., Montiel, V. R.-V., Vargas, E., Teymourian, H., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00553 · Cited by 237 · see citing works
Kwon, Y.-T., Kim, Y.-S., Kwon, S., Mahmood, M., Lim, H.-R., Park, S.-W., Kang, S.-O., Choi, J. J., Herbert, R., Jang, Y. C., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17288-0 · Cited by 233 · see citing works
Peng, B., Zhao, F., Ping, J., & Ying, Y. (2020) · Small · doi:10.1002/smll.202002681 · Cited by 224 · see citing works
Recent Advances in Intelligent Wearable Medical Devices Integrating Biosensing and Drug Delivery
Tan, M., Xu, Y., Gao, Z., Yuan, T., Liu, Q., Yang, R., Zhang, B., & Peng, L. (2022) · Advanced Materials · doi:10.1002/adma.202108491 · Cited by 187 · see citing works
Graphene-based wearable sensors
Qiao, Y., Li, X., Hirtz, T., Deng, G., Wei, Y., Li, M., Ji, S., Wu, Q., Jian, J., Wu, F., et al. (2019) · Nanoscale · doi:10.1039/c9nr05532k · Cited by 158 · see citing works
Sun, W., Guo, Z., Yang, Z., Wu, Y., Lan, W., Liao, Y., Wu, X., & Liu, Y. (2022) · Sensors · doi:10.3390/s22207784 · Cited by 112 · see citing works
6G Communication Technology: A Vision on Intelligent Healthcare
Nayak, S., & Patgiri, R. (2021) · Studies in Computational Intelligence · doi:10.1007/978-981-15-9735-0_1 · Cited by 143 · see citing works
Yang, B., Kong, J., & Fang, X. (2019) · Talanta · doi:10.1016/j.talanta.2019.06.031 · Cited by 83 · see citing works
Recent advances in flexible sweat glucose biosensors
Zhou, W., He, Q., Ye, H., Ye, C., Wu, X., & Chu, J. (2021) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ac14ef · Cited by 40 · see citing works
- Authors
- Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A.
- Affiliations
- University of Bath (GB)
- Venue
- Nature Nanotechnology
- Published
- 2018-04-09
- Volume
- 13
- Issue
- 6
- Pages
- 504-511
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2796826964
- Cited by
- 340
- References
- 37
- Citations by year
- 2026: 16 · 2025: 34 · 2024: 44 · 2023: 53 · 2022: 49 · 2021: 49 · 2020: 43 · 2019: 38 · 2018: 14
- FWCI
- 13.78
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature Nanotechnology (publishedVersion)
- PubMed (publishedVersion)
- Pure (University of Bath) (acceptedVersion, other-oa)
- Funders
- Alexander and Margaret Stewart Trust
- University of Bath
- Sir Halley Stewart Trust
- Medical Research Council (MC_PC_14106)
- Engineering and Physical Sciences Research Council (EP/M507295/1, EP/G036101/1, EP/G036101)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
- Keywords
- non-invasive glucose monitoring, interstitial fluid, graphene films, screen printing, diabetes mellitus, continuous glucose monitoring, blood glucose monitoring
- MeSH terms
- Animals, Equipment Design, Glucose, Graphite, Humans, Skin, Swine, Blood Glucose Self-Monitoring, Biosensing Techniques, Extracellular Fluid, Electroosmosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review