Rapid Prototyping of Concave Microwells for the Formation of 3D Multicellular Cancer Aggregates for Drug Screening
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Microwell technology has revolutionized many aspects of in vitro cellular studies from 2D traditional cultures to 3D in vivo‐like functional assays. However, existing lithography‐based approaches are often costly and time‐consuming. This study presents a rapid, low‐cost prototyping method of CO 2 laser ablation of a conventional untreated culture dish to create concave microwells used for generating multicellular aggregates, which can be readily available for general laboratories. Polymethylmethacrylate (PMMA), polydimethylsiloxane (PDMS), and polystyrene (PS) microwells are investigated, and each produces distinctive microwell features. Among these three materials, PS cell culture dishes produce the optimal surface smoothness and roundness. A549 lung cancer cells are grown to form cancer aggregates of controllable size from ≈40 to ≈80 μm in PS microwells. Functional assays of spheroids are performed to study migration on 2D substrates and in 3D hydrogel conditions as a step towards recapitulating the dissemination of cancer cells. Preclinical anti‐cancer drug screening is investigated and reveals considerable differences between 2D and 3D conditions, indicating the importance of assay type as well as the utility of the present approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969
Dynamics of the Self-Assembly of Complex Cellular Aggregates on Micromolded Nonadhesive Hydrogels
Napolitano, A. P., Chai, P., Dean, D. M., & Morgan, J. R. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0190 · Cited by 228
A gel-free 3D microfluidic cell culture system
Ong, S.-M., Zhang, C., Toh, Y.-C., Kim, S. H., Foo, H. L., Tan, C. H., van Noort, D., Park, S., & Yu, H. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.022 · Cited by 172
Cited by
Latest Advances in Cryogel Technology for Biomedical Applications
Memic, A., Colombani, T., Eggermont, L. J., Rezaeeyazdi, M., Steingold, J., Rogers, Z. J., Navare, K. J., Mohammed, H. S., & Bencherif, S. A. (2019) · Advanced Therapeutics · doi:10.1002/adtp.201800114 · Cited by 310
Khoo, B. L., Grenci, G., Lim, Y. B., Lee, S. C., Han, J., & Lim, C. T. (2018) · Nature Protocols · doi:10.1038/nprot.2017.125 · Cited by 172
Bai, J., Adriani, G., Dang, T.-M., Tu, T.-Y., Leong Penny, H.-X., Wong, S.-C., Kamm, R. D., & Thiery, J.-P. (2015) · Oncotarget · doi:10.18632/oncotarget.4716 · Cited by 110
Self-citationCharacterizing the role of monocytes in T cell cancer immunotherapy using a 3d microfluidic model
Lee, S. W. L., Adriani, G., Ceccarello, E., Pavesi, A., Tan, A. T., Bertoletti, A., Kamm, R. D., & Wong, S. C. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.00416 · Cited by 109
“Formation of Tumor cell aggregates HepG2-preS1-GFP cells were used to form cell aggregates following a previously reported protocol (50).”
MethodSelf-citationIn vitro 3d cultures to model the tumor microenvironment
Fontana, F., Marzagalli, M., Sommariva, M., Gagliano, N., & Limonta, P. (2021) · Cancers · doi:10.3390/cancers13122970 · Cited by 103
Metadata
- Authors
- Tu, T., Wang, Z., Bai, J., Sun, W., Peng, W. K., Huang, R. Y., Thiery, J., & Kamm, R. D.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2013-08-27
- Volume
- 3
- Issue
- 4
- Pages
- 609-616
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2138536085
- Cited by
- 94
- References
- 3
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.