The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Melt Electrospinning Writing of Poly‐Hydroxymethylglycolide‐co‐ε‐Caprolactone‐Based Scaffolds for Cardiac Tissue Engineering
Open accessAbstract
Current limitations in cardiac tissue engineering revolve around the inability to fully recapitulate the structural organization and mechanical environment of native cardiac tissue. This study aims at developing organized ultrafine fiber scaffolds with improved biocompatibility and architecture in comparison to the traditional fiber scaffolds obtained by solution electrospinning. This is achieved by combining the additive manufacturing of a hydroxyl‐functionalized polyester, (poly(hydroxymethylglycolide‐co‐ε‐caprolactone) (pHMGCL), with melt electrospinning writing (MEW). The use of pHMGCL with MEW vastly improves the cellular response to the mechanical anisotropy. Cardiac progenitor cells (CPCs) are able to align more efficiently along the preferential direction of the melt electrospun pHMGCL fiber scaffolds in comparison to electrospun poly(ε‐caprolactone)‐based scaffolds. Overall, this study describes for the first time that highly ordered microfiber (4.0–7.0 µm) scaffolds based on pHMGCL can be reproducibly generated with MEW and that these scaffolds can support and guide the growth of CPCs and thereby potentially enhance their therapeutic potential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
Direct writing by way of melt electrospinning
Brown, T. D., Dalton, P. D., & Hutmacher, D. W. (2011) · Advanced Materials · doi:10.1002/adma.201103482 · Cited by 800
Brown, T. D., Edin, F., Detta, N., Skelton, A. D., Hutmacher, D. W., & Dalton, P. D. (2014) · Materials Science and Engineering: C · doi:10.1016/j.msec.2014.07.034 · Cited by 170
Cited by
Electrospinning and Electrospun Nanofibers: Methods, Materials, and Applications
Xue, J., Wu, T., Dai, Y., & Xia, Y. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00593 · Cited by 5,015
From Shape to Function: The Next Step in Bioprinting
Levato, R., Jungst, T., Scheuring, R. G., Blunk, T., Groll, J., & Malda, J. (2020) · Advanced Materials · doi:10.1002/adma.201906423 · Cited by 476
Self-citationOptimizing scaffold pore size for tissue engineering: insights across various tissue types
Mukasheva, F., Adilova, L., Dyussenbinov, A., Yernaimanova, B., Abilev, M., & Akilbekova, D. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1444986 · Cited by 468
PCL-Based Composite Scaffold Matrices for Tissue Engineering Applications
Siddiqui, N., Asawa, S., Birru, B., Baadhe, R., & Rao, S. (2018) · Molecular Biotechnology · doi:10.1007/s12033-018-0084-5 · Cited by 461
3D Bioprinting: from Benches to Translational Applications
Heinrich, M. A., Liu, W., Jimenez, A., Yang, J., Akpek, A., Liu, X., Pi, Q., Mu, X., Hu, N., Schiffelers, R. M., et al. (2019) · Small · doi:10.1002/smll.201805510 · Cited by 437
Metadata
- Authors
- Castilho, M., Feyen, D., Flandes‐Iparraguirre, M., Hochleitner, G., Groll, J., Doevendans, P. A. F., Vermonden, T., Ito, K., Sluijter, J. P. G., & Malda, J.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2017-07-12
- Volume
- 6
- Issue
- 18
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2735730565
- Cited by
- 204
- References
- 3
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.