The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Skin Conformal Polymer Electrodes for Clinical ECG and EEG Recordings
Abstract
Preparation‐free and skin compliant biopotential electrodes with high recording quality enable wearables for future healthcare and the Internet of Humans. Here, super‐soft and self‐adhesive electrodes are presented for use on dry and hairy skin without skin preparation or attachment pressure. The electrodes show a skin‐contact impedance of 50 kΩ cm 2 at 10 Hz that is comparable to clinical standard gel electrodes and lower than existing dry electrodes. Microstructured electrodes inspired by grasshopper feet adhere repeatedly to the skin with a force of up to 0.1 N cm−2 without further attachment even during strong movement or deformation of the skin. Skin compliance and adhesive properties of the electrodes result in reduction of noise and motion artifacts superior to other dry electrodes reaching the performance of commercial gel electrodes. The signal quality is demonstrated by recording a high‐fidelity electrocardiograms of a swimmer in water. Furthermore, an electrode with soft macropillars is used to detect alpha activity in the electroencephalograms from the back of the head through dense hair. Compared to gel electrodes, the soft biopotential electrodes are nearly imperceptible to the wearer and cause no skin irritations even after hours of application. The electrodes presented here could combine unobtrusive and long‐term biopotential recordings with clinical‐grade signal performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable silver nanowire dry electrodes for electrophysiological sensing
Myers, A. C., Huang, H., & Zhu, Y. (2015) · RSC Advances · doi:10.1039/c4ra15101a · Cited by 231
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2020) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,002
Choi, S., Han, S. I., Kim, D., Hyeon, T., & Kim, D.-H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00706c · Cited by 591
Zhang, L., Kumar, K. S., He, H., Cai, C. J., He, X., Gao, H., Yue, S., Li, C., Seet, R. C.-S., Ren, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18503-8 · Cited by 574
Wang, M., Luo, Y., Wang, T., Wan, C., Pan, L., Pan, S., He, K., Neo, A., & Chen, X. (2021) · Advanced Materials · doi:10.1002/adma.202003014 · Cited by 451
Metadata
- Authors
- Stauffer, F., Thielen, M., Sauter, C., Chardonnens, S., Bachmann, S., Tybrandt, K., Peters, C., Hierold, C., & Vörös, J.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2018-01-13
- Volume
- 7
- Issue
- 7
- Pages
- e1700994-e1700994
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2783567422
- Cited by
- 223
- References
- 1
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.