Cited by 231Nanomaterials and Printing TechnologiesAdvanced Sensor and Energy Harvesting MaterialsNeuroscience and Neural Engineering

Wearable silver nanowire dry electrodes for electrophysiological sensing

Open access
Myers, Amanda C., Huang, He, Zhu, Yong·2015·RSC Advances

Abstract

We present wearable dry electrodes made of silver nanowires for long-term electrophysiological sensing such as electrocardiography and electromyography.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c4ra15101a

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • AgNW/PDMS dry electrodes showed comparable performance with pregelled Ag/AgCl electrodes when the subject was resting and outperformed them with less motion artifacts under movements.

    “It turned out that the AgNW/ PDMS dry electrodes showed comparable performance with the pregelled Ag/AgCl electrodes when the subject was resting and outperformed the pregelled Ag/AgCl electrodes with less motion artifacts under movements”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [92]

  • Nanomaterial-enabled dry electrodes have been demonstrated for wearable and long-term ECG sensing without irritating the skin.

    “Nanomaterialenabled dry electrodes have been demonstrated for wearable and long-term ECG sensing without irritating the skin.[92,95,100]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [92]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 33

  1. X.-F. Teng, Y.-T. Zhang, C. Poon and P. Bonato, IEEE Rev. Biomed. Eng., 2008, 1, 62.
  2. C. Pang, C. Lee and K.-Y. Suh, J. Appl. Polym. Sci., 2013, 130, 1429.
  3. D. H. Kim, N. Lu, R. Ma, Y. S. Kim, R. H. Kim, S. Wang, J. Wu, S. M. Won, H. Tao, A. Islam, K. J. Yu, T. I. Kim, R. Chowdhury, M. Ying, L. Xu, M. Li, H. Chung, H. Keum, M. McCormick, P. Liu, Y. W. Zhang, F. G. Omenetto, Y. Huang, T. Coleman and J. A. Rogers, Science, 2011, 333, 838.
  4. T. Yamada, Y. Hayamizu, Y. Yamamoto, Y. Yomogida, A. Izadi-Najafabadi, D. N. Futaba and K. Hata, Nat. Nanotechnol., 2011, 6, 296.
  5. T. Sekitani, U. Zschieschang, H. Klauk and T. Someya, Nat. Mater., 2010, 9, 1015.
  6. D. H. Kim, N. Lu, R. Ghaffari, Y. S. Kim, S. P. Lee, L. Xu, J. Wu, R. H. Kim, J. Song, Z. Liu, J. viventi, B. de Graff, B. Elolampi, M. Mansour, M. J. Slepian, S. Hwang, J. D. Moss, S. M. Won, Y. Huang, B. Litt and J. A. Rogers, Nat. Mater., 2011, 10, 316.
  7. A. Searle and L. Kirkup, Physiol. Meas., 2000, 21, 271.
  8. Y. M. Chi, T.-P. Jung and G. Cauwenberghs, IEEE Rev. Biomed. Eng., 2010, 3, 106.
  9. P. J. Xu, H. Zhang and X. M. Tao, Text. Prog., 2008, 40, 183.
  10. A. Gruetzmann, S. Hansen and J. Müller, Physiol. Meas., 2007, 28, 1375.
  11. L. M. Yu, F. E. H. Tay, D. G. Guo, L. Xu and K. L. Yap, Sens. Actuators, A, 2009, 151, 17.
  12. H.-C. Jung, J.-H. Moon, D.-H. Baek, J.-H. Lee, Y.-Y. Choi, J.-S. Hong and S.-H. Lee, IEEE Trans. Biomed. Eng., 2012, 59, 1472.
  13. J.-Y. Baek, J.-H. An, J.-M. Choi, K.-S. Park and S.-H. Lee, Sens. Actuators, A, 2008, 143, 423.
  14. P. Salvo, R. Raedt, E. Carrette, D. Schaubroeck, J. Vaneteren and L. Cardon, Sens. Actuators, A, 2012, 174, 96.
  15. K. Hoffmann and R. Ruff, Proc. IEEE Eng. Med. Bio. Soc., 2007, 5739.
  16. R. Ma, D.-H. Kim, M. McCormick, T. Coleman and J. Rogers, Proc. IEEE Eng. Med. Bio. Soc., 2010, 6405.
  17. J.-W. Jeong, M.-K. Kim, H. Cheng, W.-H. Yeo, X. Huang, Y. Liu, Y. Zhang, Y. Huang and J. A. Rogers, Adv. Healthcare Mater., 2014, 3, 642.
  18. C.-Y. Chen, C.-L. Chang, T.-F. Chien and C.-H. Luo, Sens. Actuators, A, 2013, 203, 20.
  19. C.-Y. Chen, C.-L. Chang, C.-W. Chang, S.-C. Lai, T.-F. Chien, H.-Y. Huang, J.-C. Chiou and C.-H. Luo, Sensors, 2013, 13, 3077.
  20. C.-T. Lin, L.-D. Liao, Y.-H. Liu, I.-J. Wang, B.-S. Lin and J.-Y. Chang, IEEE Trans. Biomed. Eng., 2011, 58, 1200.
  21. T. Oh, S. Yoon, T. Kim, H. Wi, K. Kim, E. Woo and R. Sadleir, IEEE Trans. Biomed. Cir. Sys., 2013, 7, 204.
  22. F. Xu and Y. Zhu, Adv. Mater., 2012, 24, 5117.
  23. H. Johnston, G. Hutchison, F. Christensen, S. Peters, S. Hankin and V. Stone, Crit. Rev. Toxicol., 2010, 40, 328.
  24. F. Christensen, H. Johnston, V. Stone, R. Aitken, S. Hankin, S. Peters and K. Aschberger, Nanotoxicology, 2010, 4, 284.
  25. Y. Xiong, M. Brunson, J. Huh, A. Huang, A. Coster, K. Wendt, J. Fay and D. Qin, Small, 2013, 9, 2628.
  26. S. Yao and Y. Zhu, Nanoscale, 2014, 6, 2345.
  27. L. Song, A. C. Myers, J. J. Adams and Y. Zhu, ACS Appl. Mater. Interfaces, 2014, 6, 4248.
  28. Z. Cui, F. Robles-Poblete, G. Cheng, S. Yao, X. Jiang and Y. Zhu, J. Mater. Res., 2015, 30, 79.
  29. Y. Sun, B. Mayers, T. Herricks and Y. Xia, Nano Lett., 2003, 3, 955.
  30. B. Wiley, Y. Sun and Y. Xia, Acc. Chem. Res., 2007, 40, 1067.
  31. W. Franks, I. Schenker, P. Schmutz and A. Hierlemann, IEEE Trans. Biomed. Eng., 2005, 52, 1295.
  32. C.-H. Liu and X. Yu, Nanoscale Res. Lett., 2011, 6, 75.
  33. W. J. Lee, M. Y. Lee, A. K. Roy, K. S. Lee, S. Y. Park and I. In, Chem. Lett., 2013, 42, 191.

Cited by

Sorted by citations

Authors
Myers, A. C., Huang, H., & Zhu, Y.
Affiliations
  • North Carolina State University (US)
  • University of North Carolina at Chapel Hill (US)
Corresponding author
Zhu, Yong
Venue
RSC Advances
Published
2015
Volume
5
Issue
15
Pages
11627-11632
ISSN
2046-2069 (ISSN-L)
OpenAlex
W2125038391
Cited by
231
References
36
Citations by year
2026: 10 · 2025: 7 · 2024: 21 · 2023: 20 · 2022: 24 · 2021: 28 · 2020: 26 · 2019: 33 · 2018: 25 · 2017: 16 · 2016: 16 · 2015: 5
FWCI
9.95
Type
journal article
Language
en
Open access
Locations
  • RSC Advances (publishedVersion)
  • Carolina Digital Repository (University of North Carolina at Chapel Hill) (submittedVersion)
  • UNC Libraries
Funders
Division of Engineering Education and Centers (EEC-1160483)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
silver nanowires, dry electrodes, wearable sensors, electrocardiogram, electromyography, long-term monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review