The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Highly Sensitive Flexible Iontronic Pressure Sensor for Fingertip Pulse Monitoring
Abstract
The pulse is a key biomedical signal containing various human physiological and pathological information highly related to cardiovascular diseases. Pulse signals are often collected from the radial artery based on Traditional Chinese Medicine, or by using flexible pressure sensors. However, the wrist wrapped with a flexible pressure sensor exhibits unstable signals under hand motion because of the concave surface of the wrist. By contrast, fingertips have a convex surface and therefore show great promises in stable and long‐term pulse monitoring. Despite the promising potential, the fingertip pulse signal is weak, calling for highly sensitive detecting devices. Here, a highly sensitive and flexible iontronic pressure sensor with a linear sensitivity of 13.5 kPa−1, a swift response, and remarkable stability over 5000 loading/unloading cycles is developed. This sensor enables stable and high‐resolution detection of pulse waveform under both static condition and finger motion. Fingertip pulse waveforms from subjects of different genders, age, and health conditions are collected and analyzed, suggesting that fingertip pulse information is highly similar to that of the radial artery. This work justifies that fingertip is an ideal platform for pulse signals monitoring, which would be a competitive alternative to existing complex health monitoring systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Joo, Y., Byun, J., Seong, N., Ha, J., Kim, H., Kim, S., Kim, T., Im, H., Kim, D., & Hong, Y. (2015) · Nanoscale · doi:10.1039/c5nr00313j · Cited by 378
Droplet-based interfacial capacitive sensing
Nie, B., Xing, S., Brandt, J. D., & Pan, T. (2012) · Lab on a Chip · doi:10.1039/c2lc21168h · Cited by 216
Rajala, S., Lindholm, H., & Taipalus, T. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac7ac · Cited by 70
Cited by
Wearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 878
Recent Progress in Essential Functions of Soft Electronic Skin
Chen, J., Zhu, Y., Chang, X., Pan, D., Song, G., Guo, Z., & Naik, N. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104686 · Cited by 393
Yang, R., Dutta, A., Li, B., Tiwari, N., Zhang, W., Niu, Z., Gao, Y., Erdely, D., Xin, X., Li, T., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-38274-2 · Cited by 390
Self-citationIonic Flexible Sensors: Mechanisms, Materials, Structures, and Applications
Zhao, C., Wang, Y., Tang, G., Ru, J., Zhu, Z., Li, B., Guo, C. F., Li, L., & Zhu, D. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202110417 · Cited by 290
Self-citation
Metadata
- Authors
- Lin, Q., Huang, J., Yang, J., Huang, Y., Zhang, Y., Wang, Y., Zhang, J., Wang, Y., Yuan, L., Cai, M., Hou, X., Zhang, W., Zhou, Y., Chen, S. G., & Guo, C. F.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2020-07-29
- Volume
- 9
- Issue
- 17
- Pages
- e2001023-e2001023
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W3046597582
- Cited by
- 197
- References
- 4
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive Flexible Iontronic Pressure Sensor for Fingertip Pulse Monitoring. https://app.cochat.ai/papers/10.1002/adhm.202001023
- The paper
- Lin, Q., Huang, J., Yang, J., Huang, Y., Zhang, Y., Wang, Y., Zhang, J., Wang, Y., Yuan, L., Cai, M., Hou, X., Zhang, W., Zhou, Y., Chen, S. G., & Guo, C. F. (2020). Highly Sensitive Flexible Iontronic Pressure Sensor for Fingertip Pulse Monitoring. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202001023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.