Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 197

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Highly Sensitive Flexible Iontronic Pressure Sensor for Fingertip Pulse Monitoring

Lin, Qiupeng, Huang, Jun, Yang, Junlong, Huang, Yi, Zhang, Yifan, Wang, Yueji, Zhang, Jianming, Wang, Yan, Yuan, Linlin, Cai, Minkun, Hou, Xingyu, Zhang, Weixing, Zhou, Yunlong, Chen, Shi Guo, Guo, Chuan Fei · 2020 · Advanced Healthcare Materials

Abstract

The pulse is a key biomedical signal containing various human physiological and pathological information highly related to cardiovascular diseases. Pulse signals are often collected from the radial artery based on Traditional Chinese Medicine, or by using flexible pressure sensors. However, the wrist wrapped with a flexible pressure sensor exhibits unstable signals under hand motion because of the concave surface of the wrist. By contrast, fingertips have a convex surface and therefore show great promises in stable and long‐term pulse monitoring. Despite the promising potential, the fingertip pulse signal is weak, calling for highly sensitive detecting devices. Here, a highly sensitive and flexible iontronic pressure sensor with a linear sensitivity of 13.5 kPa−1, a swift response, and remarkable stability over 5000 loading/unloading cycles is developed. This sensor enables stable and high‐resolution detection of pulse waveform under both static condition and finger motion. Fingertip pulse waveforms from subjects of different genders, age, and health conditions are collected and analyzed, suggesting that fingertip pulse information is highly similar to that of the radial artery. This work justifies that fingertip is an ideal platform for pulse signals monitoring, which would be a competitive alternative to existing complex health monitoring systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adhm.202001023

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 197

Metadata

Authors
Lin, Q., Huang, J., Yang, J., Huang, Y., Zhang, Y., Wang, Y., Zhang, J., Wang, Y., Yuan, L., Cai, M., Hou, X., Zhang, W., Zhou, Y., Chen, S. G., & Guo, C. F.
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2020-07-29
Volume
9
Issue
17
Pages
e2001023-e2001023
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W3046597582
Cited by
197
References
4
FWCI
7.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Sensitive Flexible Iontronic Pressure Sensor for Fingertip Pulse Monitoring. https://app.cochat.ai/papers/10.1002/adhm.202001023
The paper
Lin, Q., Huang, J., Yang, J., Huang, Y., Zhang, Y., Wang, Y., Zhang, J., Wang, Y., Yuan, L., Cai, M., Hou, X., Zhang, W., Zhou, Y., Chen, S. G., & Guo, C. F. (2020). Highly Sensitive Flexible Iontronic Pressure Sensor for Fingertip Pulse Monitoring. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202001023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.