Comparison of photoplethysmogram measured from wrist and finger and the effect of measurement location on pulse arrival time

Open access
Rajala, Satu, Lindholm, Harri, Taipalus, Tapio·2018·Physiological Measurement

Abstract

OBJECTIVE: The aim of this paper was to compare photoplethysmogram (PPG) signals measured from the wrist and finger and to evaluate if wrist PPG signal could be used to calculate pulse arrival time (PAT), the time delay between electrocardiogram (ECG) R peak and a feature (e.g. peak, foot, first derivative peak) in the PPG signal. Further, the correlation between pulse wave velocity (rePWV, defined as PWV from ECG R peak to extremity) and systolic blood pressure was studied. APPROACH: Thirty subjects were measured at rest by a trained research nurse. For reference measurement, chest ECG and finger PPG were measured using commercial sensors. Wrist PPG and arm ECG were measured with a custom-made setup, where the PPG sensor was located at the back surface of the forearm. MAIN RESULTS: Reference finger and wrist PPG signals were found to differ in shape and also in amplitude. The PPG foot or first derivative peak detection methods seemed to be the most suitable methods for wrist PAT calculation. The Pearson correlation coefficient between blood pressure and rePWV was found to be 0.44 for the reference finger measurement and 0.37 for the wrist measurement. SIGNIFICANCE: Wrist PPG signal is widely used in optical heart rate monitors. Based on the results obtained in this study, wrist PPG signal may be used also for PAT calculation. The use of PAT for blood pressure estimation still has challenges, but PAT as such could be used as an interesting indicator of vascular health.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1361-6579/aac7ac

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Rajala, S., Lindholm, H., & Taipalus, T.
Affiliations
Nokia (Finland) (FI)
Corresponding author
Rajala, Satu
Venue
Physiological Measurement
Published
2018-07-01
Volume
39
Issue
7
Pages
075010
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2804099118
Cited by
70
References
46
Citations by year
2026: 2 · 2025: 12 · 2024: 6 · 2023: 7 · 2022: 13 · 2021: 14 · 2020: 10 · 2019: 5 · 2018: 1
FWCI
3.00
Type
journal article
Language
en
Open access
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
photoplethysmogram, finger PPG, pulse arrival time, pulse wave velocity, measurement location, systolic blood pressure, vascular health
MeSH terms
Adult, Electrocardiography, Female, Fingers, Humans, Male, Middle Aged, Wrist, Photoplethysmography, Pulse Wave Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review