Droplet-based interfacial capacitive sensing
Abstract
This paper presented a novel droplet-based pressure sensor using elastic and capacitive electrode-electrolyte interfaces to achieve ultrahigh mechanical-to-electrical sensitivity (1.58 μF kPa(-1)) and resolution (1.8 Pa) with a simple device architecture. The miniature transparent droplet sensors, fabricated by one-step laser micromachining, consisted of two flexible polymer membranes with conductive coating and a separation layer hosting a sensing chamber for an electrolyte droplet. The sensing principle primarily relied on high elasticity of the sensing droplet and large capacitance presented at the electrode-electrolyte interface. A simple surface modification scheme was introduced to the conductive coating, which reduced hysteresis of the droplet deformation without substantially compromising the interfacial capacitance. Moreover, the major concern of liquid evaporation was addressed by a mixture of glycerol and electrolyte with long-term stability in a laboratory environment. Theoretical analyses and experimental investigations on several design parameters (i.e., the dimensions of the sensing chamber and the droplet size) were thoroughly conducted to characterize and optimize the overall sensitivity of the device. Moreover, the environmental influences (e.g., temperature and humidity) on the capacitive measurement were further investigated. Finally, the simply constructed and mechanically flexible droplet sensor was successfully applied to detect minute blood pressure variations on the skin surface (with the maximum value less than 100 Pa) throughout cardiovascular cycles.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For wearable pressure sensors used for healthcare applications, the sensors should be highly compliant to accommodate skin deformations and highly sensitive to capture small pressure associated with biosignals such as blood pulse or respiration, where pressure down to tens of Pa can be involved.
“For wearable pressure sensors that are used for healthcare applications, the sensors should be highly compliant to accommodate the skin deformations and highly sensitive to capture small pressure associated with biosignals such as blood pulse or respiration, where pressure down to tens of Pa can be involved.[6,138]”
From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [138]
Cites
Materials for electrochemical capacitors
Simon, P., & Gogotsi, Y. G. (2008) · Nature Materials · doi:10.1038/nmat2297 · Cited by 16,474 · see citing works
Timoshenko, S. P., & Woinowsky-Krieger, S. (1959) · UCLA Biblioteca de Ingenieria Civil · Cited by 12,018 · see citing works
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291 · see citing works
Soft lithography for micro- and nanoscale patterning
Qin, D., Xia, Y., & Whitesides, G. M. (2010) · Nature Protocols · doi:10.1038/nprot.2009.234 · Cited by 2,339 · see citing works
Viscosity of Glycerol and Its Aqueous Solutions
Segur, J. B., & Oberstar, H. E. (1951) · Industrial & Engineering Chemistry · doi:10.1021/ie50501a040 · Cited by 836 · see citing works
A Gouy–Chapman–Stern model of the double layer at a (metal)/(ionic liquid) interface
Oldham, K. B. (2007) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2007.10.017 · Cited by 620 · see citing works
Yuan, H., Shimotani, H., Tsukazaki, A., Ohtomo, A., Kawasaki, M., & Iwasa, Y. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801633 · Cited by 600 · see citing works
Liquid-gated interface superconductivity on an atomically flat film
Ye, J. T., Inoue, S., Kobayashi, K., Kasahara, Y., Yuan, H., Shimotani, H., & Iwasa, Y. (2009) · Nature Materials · doi:10.1038/nmat2587 · Cited by 591 · see citing works
A comprehensive equation for the pulmonary pressure-volume curve
Venegas, J. G., Harris, R. S., & Simon, B. A. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.389 · Cited by 577 · see citing works
Optical methods for sensing glucose
Steiner, M., Duerkop, A., & Wolfbeis, O. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15063d · Cited by 498 · see citing works
Stretchable Microfluidic Radiofrequency Antennas
Kubo, M., Li, X., Kim, C., Hashimoto, M., Wiley, B. J., Ham, D., & Whitesides, G. M. (2010) · Advanced Materials · doi:10.1002/adma.200904201 · Cited by 450 · see citing works
Microchip-based immunomagnetic detection of circulating tumor cells
Hoshino, K., Huang, Y.-Y., Lane, N., Huebschman, M., Uhr, J. W., Frenkel, E. P., & Zhang, X. (2011) · Lab on a Chip · doi:10.1039/c1lc20270g · Cited by 400 · see citing works
Lee, H.-K., Chung, J., Chang, S.-I., & Yoon, E. (2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.921727 · Cited by 351 · see citing works
Ocular Biomechanics and Biotransport
Ethier, C. R., Johnson, M. F., & Ruberti, J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140055 · Cited by 290 · see citing works
Flat and Corrugated Diaphragm Design Handbook
Giovanni, M. D. (2017) · Routledge eBooks · doi:10.1201/9780203755969 · Cited by 235 · see citing works
THE NORMAL BLOOD PRESSURE RANGE AND ITS CLINICAL IMPLICATIONS
Mastér, A. M. (1950) · JAMA · doi:10.1001/jama.1950.02910520006004 · Cited by 231 · see citing works
Microfluidic stretchable RF electronics
Cheng, S., & Wu, Z. (2010) · Lab on a Chip · doi:10.1039/c005159d · Cited by 177 · see citing works
Monte Carlo simulation of an ion-dipole mixture as a model of an electrical double layer
Boda, D., Chan, K., & Henderson, D. J. (1998) · The Journal of Chemical Physics · doi:10.1063/1.477342 · Cited by 152 · see citing works
A three-component model of the electrical double layer
Tang, Z., Scriven, L. E., & DAVIS, H. T. (1992) · The Journal of Chemical Physics · doi:10.1063/1.463595 · Cited by 139 · see citing works
A novel capacitive pressure sensor based on sandwich structures
Zhou, M.-X., Huang, Q., Qin, M. L., et al. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859100 · Cited by 115 · see citing works
Wu, C., Liao, W., & Tung, Y. (2011) · Lab on a Chip · doi:10.1039/c0lc00620c · Cited by 105 · see citing works
Thermodynamic equilibrium of organic‐electrolyte mixtures in aerosol particles
Ming, Y., & Russell, L. M. (2002) · AIChE Journal · doi:10.1002/aic.690480619 · Cited by 99 · see citing works
A Low-Power Low-Noise Dual-Chopper Amplifier for Capacitive CMOS-MEMS Accelerometers
Sun, H., Fang, D., Jia, K., Maarouf, F., Qu, H., & Xie, H. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2064296 · Cited by 78 · see citing works
Li, Y., Shirahata, N., Saini, G., et al. (2009) · Langmuir · doi:10.1021/la804272n · Cited by 77 · see citing works
From Cleanroom to Desktop: Emerging Micro-Nanofabrication Technology for Biomedical Applications
Pan, T., & Wang, W. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0218-9 · Cited by 71 · see citing works
Self-citationMosadegh, B., Tavana, H., Lesher‐Pérez, S. C., et al. (2010) · Lab on a Chip · doi:10.1039/c0lc00112k · Cited by 51 · see citing works
Dynamic behavior of single glycerol droplets in humid air streams
Ray, A., Johnson, R. D., & Souyri, A. (1989) · Langmuir · doi:10.1021/la00085a024 · Cited by 49 · see citing works
Photopatternable Superhydrophobic Nanocomposites for Microfabrication
Hong, L., & Pan, T. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2041189 · Cited by 45 · see citing works
Self-citationYu, Q., Shi, Z., Liu, X., et al. (2011) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2010.12.030 · Cited by 44 · see citing works
Vapor Pressures of Glycerol-Water and Glycerol-Water-Sodium Chloride Systems
Carr, A. R., Townsend, R., & Badger, W. L. (1925) · Industrial & Engineering Chemistry · doi:10.1021/ie50186a043 · Cited by 42 · see citing works
Novel Capacitive Pressure Sensor
Bakhoum, E. G., & Cheng, M. H. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2047632 · Cited by 41 · see citing works
Yunus, S., de Looringhe, C. D. C., Poleunis, C., et al. (2007) · Surface and Interface Analysis · doi:10.1002/sia.2623 · Cited by 40 · see citing works
Multiplex pressure measurement in microsystems using volume displacement of particle suspensions
Chung, K., Lee, H., & Lu, H. (2009) · Lab on a Chip · doi:10.1039/b911480g · Cited by 36 · see citing works
A slow-adapting microfluidic-based tactile sensor
Tseng, W.-Y., Fisher, J. S., Prieto, J. L., et al. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/8/085002 · Cited by 31 · see citing works
Aptamer-modified anodized aluminum oxide-based capacitive sensor for the detection of bisphenol A
Kang, B., Kim, J. H., Kim, S., et al. (2011) · Applied Physics Letters · doi:10.1063/1.3555345 · Cited by 26 · see citing works
Limits to Nanopatterning of Fluids on Surfaces in Soft Lithography
Wigenius, J. A., Hamedi, M. M., & Inganäs, O. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200800073 · Cited by 26 · see citing works
Development and application of a real-time capacitive sensor
Wongkittisuksa, B., Limsakul, C., Kanatharana, P., et al. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.10.033 · Cited by 19 · see citing works
Zeng, H., & Zhao, Y. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.11.069 · Cited by 16 · see citing works
Al-Gayem, Q., Richardson, A., Liu, H., et al. (2011) · Journal of Electronic Testing · doi:10.1007/s10836-011-5203-1 · Cited by 13 · see citing works
A microfluidic system for fast detection of mitochondrial DNA deletion
Chang, C.-M., Chiu, L.-F., Wang, P., Shieh, D.-B., & Lee, G. (2011) · Lab on a Chip · doi:10.1039/c1lc20317g · Cited by 11 · see citing works
Glass-based integrated capacitive sensors for detection of the neurotransmitter dopamine
Chen, L.-G., & Lu, M. S.-C. (2011) · Micro & Nano Letters · doi:10.1049/mnl.2011.0117 · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641 · see citing works
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434 · see citing works
Self-citationMonitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408 · see citing works
Nanomaterial-Enabled Wearable Sensors for Healthcare
Yao, S., Swetha, P., & Zhu, Y. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700889 · Cited by 576 · see citing works
Emerging Technologies of Flexible Pressure Sensors: Materials, Modeling, Devices, and Manufacturing
Huang, Y., Fan, X., Chen, S., & Zhao, N. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808509 · Cited by 543 · see citing works
Yuan, H., Zhang, Q., Zhou, T., Wu, W., Li, H., Yin, Z., Ma, J., & Jiao, T. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.149926 · Cited by 180 · see citing works
Sun, W., Guo, Z., Yang, Z., Wu, Y., Lan, W., Liao, Y., Wu, X., & Liu, Y. (2022) · Sensors · doi:10.3390/s22207784 · Cited by 112 · see citing works
Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring
Digiglio, P., Li, R., Wang, W., & Pan, T. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1037-1 · Cited by 38 · see citing works
Self-citation
- Authors
- Nie, B., Xing, S., Brandt, J. D., & Pan, T.
- Affiliations
- University of California, Davis (US)
- Corresponding author
- Pan, Tingrui
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 6
- Pages
- 1110
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1995334462
- Cited by
- 216
- References
- 41
- Citations by year
- 2026: 26 · 2025: 33 · 2024: 26 · 2023: 17 · 2022: 22 · 2021: 22 · 2020: 9 · 2019: 17 · 2018: 8 · 2017: 14 · 2016: 3 · 2015: 5 · 2014: 9 · 2013: 3 · 2012: 2
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Computer Science › Computer Networks and Communications › Sensor Technology and Measurement Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
- Keywords
- interfacial capacitance, electrode-electrolyte interface, conductive coatings, surface modification, hysteresis reduction, liquid evaporation, glycerol electrolyte, laser micromachining, blood pressure sensing, temperature and humidity effects
- MeSH terms
- Electrodes, Electrolytes, Equipment Design, Humans, Sensitivity and Specificity, Surface Properties, Blood Pressure Monitors, Electric Capacitance, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review