Cited by 216Advanced Sensor and Energy Harvesting MaterialsSensor Technology and Measurement SystemsNanomaterials and Printing Technologies

Droplet-based interfacial capacitive sensing

Nie, Baoqing, Xing, Siyuan, Brandt, James D., Pan, Tingrui·2012·Lab on a Chip

Abstract

This paper presented a novel droplet-based pressure sensor using elastic and capacitive electrode-electrolyte interfaces to achieve ultrahigh mechanical-to-electrical sensitivity (1.58 μF kPa(-1)) and resolution (1.8 Pa) with a simple device architecture. The miniature transparent droplet sensors, fabricated by one-step laser micromachining, consisted of two flexible polymer membranes with conductive coating and a separation layer hosting a sensing chamber for an electrolyte droplet. The sensing principle primarily relied on high elasticity of the sensing droplet and large capacitance presented at the electrode-electrolyte interface. A simple surface modification scheme was introduced to the conductive coating, which reduced hysteresis of the droplet deformation without substantially compromising the interfacial capacitance. Moreover, the major concern of liquid evaporation was addressed by a mixture of glycerol and electrolyte with long-term stability in a laboratory environment. Theoretical analyses and experimental investigations on several design parameters (i.e., the dimensions of the sensing chamber and the droplet size) were thoroughly conducted to characterize and optimize the overall sensitivity of the device. Moreover, the environmental influences (e.g., temperature and humidity) on the capacitive measurement were further investigated. Finally, the simply constructed and mechanically flexible droplet sensor was successfully applied to detect minute blood pressure variations on the skin surface (with the maximum value less than 100 Pa) throughout cardiovascular cycles.

Integrity signals

Registry

Crossref · 10.1039/c2lc21168h

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • For wearable pressure sensors used for healthcare applications, the sensors should be highly compliant to accommodate skin deformations and highly sensitive to capture small pressure associated with biosignals such as blood pulse or respiration, where pressure down to tens of Pa can be involved.

    “For wearable pressure sensors that are used for healthcare applications, the sensors should be highly compliant to accommodate the skin deformations and highly sensitive to capture small pressure associated with biosignals such as blood pulse or respiration, where pressure down to tens of Pa can be involved.[6,138]”

    From Nanomaterial-Enabled Wearable Sensors for Healthcare (2018) · cites this paper as [138]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Nie, B., Xing, S., Brandt, J. D., & Pan, T.
Affiliations
University of California, Davis (US)
Corresponding author
Pan, Tingrui
Venue
Lab on a Chip
Published
2012
Volume
12
Issue
6
Pages
1110
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W1995334462
Cited by
216
References
41
Citations by year
2026: 26 · 2025: 33 · 2024: 26 · 2023: 17 · 2022: 22 · 2021: 22 · 2020: 9 · 2019: 17 · 2018: 8 · 2017: 14 · 2016: 3 · 2015: 5 · 2014: 9 · 2013: 3 · 2012: 2
FWCI
2.65
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Computer Science › Computer Networks and Communications › Sensor Technology and Measurement Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
interfacial capacitance, electrode-electrolyte interface, conductive coatings, surface modification, hysteresis reduction, liquid evaporation, glycerol electrolyte, laser micromachining, blood pressure sensing, temperature and humidity effects
MeSH terms
Electrodes, Electrolytes, Equipment Design, Humans, Sensitivity and Specificity, Surface Properties, Blood Pressure Monitors, Electric Capacitance, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review