Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Wireless and Flexible Skin Moisture and Temperature Sensor Sheets toward the Study of Thermoregulator Center

Abstract

A disorder in the thermoregulator center in a human body leads to some potential diseases such as fever and hyperthyroidism. To predict these diseases early, monitoring the health condition of the human body due to the influence of thermoregulation disorders is important. Although extensive works are performed on sweat‐rate detection by constructing microfluidic channels, skin‐moisture evaporation before sweating remains unknown. This work proposes a wireless and flexible sensor sheet to investigate the thermoregulatory responses of different people under cold stimulation and exercise by measuring the temperature and moisture variations on the finger skin. An integrated flexible sensor system consists of a ZnIn 2 S 4 nanosheet‐based humidity sensor and carbon nanotube/SnO 2 temperature sensor. The results exhibit distinct thermoregulation abilities of five volunteers. Interestingly, the sudden increase in finger moisture that results from the excitation by the sympathetic nerve is observed during the cold‐stimulus test. Although further studies are required to predict the potential diseases resulted from thermoregulation disorders in human body, this study provides a possibility of continuous and real‐time monitoring of thermoregulatory activities via skin moisture and temperature detection using a flexible sensor sheet.

Overview

Integrity signals

Registry

Crossref · 10.1002/adhm.202100103

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 31 references

Research works printed but not linked: 1

  1. Nemcova A., 2020, IEEE Trans. Intell. Transp. Syst., 1, 2977762

Cited by

See all 83

Metadata

Authors
Lu, Y., Fujita, Y., Honda, S., Yang, S., Xuan, Y., Xu, K., Arie, T., Akita, S., & Takei, K.
Affiliations
Osaka Prefecture University (JP)
Corresponding author
Takei, Kuniharu
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2021-05-06
Volume
10
Issue
17
Pages
e2100103-e2100103
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W3158130207
Cited by
83
References
31
Citations by year
2026: 5 · 2025: 14 · 2024: 22 · 2023: 20 · 2022: 14 · 2021: 8
FWCI
4.86
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Healthcare Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Japan Science and Technology Agency (JPMJCR21U1)
  • Japan Society for the Promotion of Science (JP17H04926, JP18H05472)
  • Precursory Research for Embryonic Science and Technology (JPMJPR17J5)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
Keywords
thermoregulation, skin hydration, skin temperature, wireless sensors, humidity sensor, finger skin, cold stimulation, physical activity, sympathetic nervous system, sweat rate, fever, hyperthyroidism, real-time health monitoring
MeSH terms
Cold Temperature, Humans, Humidity, Skin, Sweat, Temperature

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wireless and Flexible Skin Moisture and Temperature Sensor Sheets toward the Study of Thermoregulator Center. https://app.cochat.ai/papers/10.1002/adhm.202100103
The paper
Lu, Y., Fujita, Y., Honda, S., Yang, S., Xuan, Y., Xu, K., Arie, T., Akita, S., & Takei, K. (2021). Wireless and Flexible Skin Moisture and Temperature Sensor Sheets toward the Study of Thermoregulator Center. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202100103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.