The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Conjugate Electrospun 3D Gelatin Nanofiber Sponge for Rapid Hemostasis
Abstract
Developing an excellent hemostatic material with good biocompatibility and high blood absorption capacity for rapid hemostasis of deep non‐compressible hemorrhage remains a significant challenge. Herein, a novel conjugate electrospinning strategy to prepare an ultralight 3D gelatin sponge consisting of continuous interconnected nanofibers. This unique fluffy nanofiber structure endows the sponge with low density, high surface area, compressibility, and ultrastrong liquid absorption capacity. In vitro assessments show the gelatin nanofiber sponge has good cytocompatibility, high cell permeability, and low hemolysis ratio. The rat subcutaneous implantation studies demonstrate good biocompatibility and biodegradability of gelatin nanofiber sponge. Gelatin nanofiber sponge aggregates and activates platelets in large quantities to accelerate the formation of platelet embolism, and simultaneously escalates other extrinsic and intrinsic coagulation pathways, which collectively contribute to its superior hemostatic capacity. In vivo studies on an ear artery injury model and a liver trauma model of rabbits demonstrate that the gelatin nanofiber sponge rapidly induce stable blood clots with least blood loss compared to gelatin nanofiber membrane, medical gauze, and commercial gelatin hemostatic sponge. Hence, the gelatin nanofiber sponge holds great potential as an absorbable hemostatic agent for rapid hemostasis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, X., Liang, Y., Huang, Y., He, J., Han, Y., & Guo, B. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910748 · Cited by 814
Synthetic biodegradable functional polymers for tissue engineering: a brief review
Guo, B., & Ma, P. X. (2014) · Science China Chemistry · doi:10.1007/s11426-014-5086-y · Cited by 592
Cited by
Advanced bioactive nanomaterials for biomedical applications
Zhao, Y., Zhang, Z., Pan, Z., & Liu, Y. (2021) · Exploration · doi:10.1002/exp.20210089 · Cited by 357
Engineered Hemostatic Biomaterials for Sealing Wounds
Montazerian, H., Davoodi, E., Baidya, A., Baghdasarian, S., Sarikhani, E., Meyer, C. E., Haghniaz, R., Badv, M., Annabi, N., Khademhosseini, A., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c01015 · Cited by 291
Han, X., Saengow, C., Ju, L., Ren, W., Ewoldt, R. H., & Irudayaraj, J. (2024) · Nature Communications · doi:10.1038/s41467-024-47696-5 · Cited by 273
Li, T., Sun, M., & Wu, S. (2022) · Nanomaterials · doi:10.3390/nano12050784 · Cited by 262
Emerging materials for hemostasis
Li, X.-F., Lu, P., Jia, H.-R., Li, G., Zhu, B., Wang, X., & Wu, F.-G. (2023) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2022.214823 · Cited by 164
Metadata
- Authors
- Xie, X., Li, D., Chen, Y., Shen, Y., Yu, F., Wang, W., Yuan, Z., Morsi, Y., Wu, J., & Mo, X.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2021-07-08
- Volume
- 10
- Issue
- 20
- Pages
- e2100918-e2100918
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W3182965401
- Cited by
- 223
- References
- 2
- FWCI
- 20.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conjugate Electrospun 3D Gelatin Nanofiber Sponge for Rapid Hemostasis. https://app.cochat.ai/papers/10.1002/adhm.202100918
- The paper
- Xie, X., Li, D., Chen, Y., Shen, Y., Yu, F., Wang, W., Yuan, Z., Morsi, Y., Wu, J., & Mo, X. (2021). Conjugate Electrospun 3D Gelatin Nanofiber Sponge for Rapid Hemostasis. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.202100918
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.