The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Microsolidics: Fabrication of Three‐Dimensional Metallic Microstructures in Poly(dimethylsiloxane)
Abstract
The fabrication of complex metallic microstructures in 3D by injecting liquid solder into microfluidic channels and allowing the solder to cool and solidify is demonstrated; after fabrication, the metallic structures can be flexed, bent, or twisted (see figure and cover). With this method it is possible to build flexible electronic circuits, complex embedded or freestanding 3D metal microstructures, 3D electronic components, and hybrid electronic–microfluidic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Self-citation
Cited by
Dickey, M. D., Chiechi, R. C., Larsen, R. J., Weiss, E. A., Weitz, D. A., & Whitesides, G. M. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200701216 · Cited by 1,468
Self-citationBaret, J.-C., Miller, O. J., Taly, V., Ryckelynck, M., El-Harrak, A., Frenz, L., Rick, C., Samuels, M. L., Hutchison, J. B., Agresti, J. J., et al. (2009) · Lab on a Chip · doi:10.1039/b902504a · Cited by 951
Stretchable, Large‐area Organic Electronics
Sekitani, T., & Someya, T. (2010) · Advanced Materials · doi:10.1002/adma.200904054 · Cited by 773
Tissue–electronics interfaces: from implantable devices to engineered tissues
Feiner, R., & Dvir, T. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.76 · Cited by 595
Stretchable, Curvilinear Electronics Based on Inorganic Materials
Kim, D., Xiao, J., Song, J., Huang, Y., & Rogers, J. A. (2010) · Advanced Materials · doi:10.1002/adma.200902927 · Cited by 593
Reversibly Deformable and Mechanically Tunable Fluidic Antennas
So, J., Thelen, J., Qusba, A., Hayes, G. J., Lazzi, G., & Dickey, M. D. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200900604 · Cited by 555
High-throughput injection with microfluidics using picoinjectors
Abate, A. R., Hung, T., Mary, P., Agresti, J. J., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006888107 · Cited by 502
High-throughput single-cell ChIP-seq identifies heterogeneity of chromatin states in breast cancer
Grosselin, K., Durand, A., Marsolier, J., Poitou, A., Marangoni, E., Nemati, F., Dahmani, A., Lameiras, S., Reyal, F., Frenoy, O., et al. (2019) · Nature Genetics · doi:10.1038/s41588-019-0424-9 · Cited by 466
Kim, D., Kim, Y., Wu, J., Liu, Z., Song, J., Kim, H., Huang, Y. Y., Hwang, K., & Rogers, J. A. (2009) · Advanced Materials · doi:10.1002/adma.200900405 · Cited by 403
Micro-magnetofluidics: interactions between magnetism and fluid flow on the microscale
Nguyen, N.-T. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-011-0903-5 · Cited by 390
Face-selective electrostatic control of hydrothermal zinc oxide nanowire synthesis
Joo, J., Chow, B. Y., Prakash, M., Boyden, E. S., & Jacobson, J. M. (2011) · Nature Materials · doi:10.1038/nmat3069 · Cited by 368
Wang, B. L., Ghaderi, A., Zhou, H., Agresti, J., Weitz, D. A., Fink, G. R., & Stephanopoulos, G. (2014) · Nature Biotechnology · doi:10.1038/nbt.2857 · Cited by 330
Methods to pattern liquid metals
Joshipura, I. D., Ayers, H. R., Majidi, C., & Dickey, M. D. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00330j · Cited by 326
Hohman, J. N., Kim, M., Wadsworth, G. A., Bednar, H. R., Jiang, J., LeThai, M. A., & Weiss, P. S. (2011) · Nano Letters · doi:10.1021/nl202728j · Cited by 326
Cheng, S., & Wu, Z. (2012) · Lab on a Chip · doi:10.1039/c2lc21176a · Cited by 300
Design of conductive composite elastomers for stretchable electronics
Park, M., Park, J., & Jeong, U. (2014) · Nano Today · doi:10.1016/j.nantod.2014.04.009 · Cited by 295
Recent Advances in Stretchable and Transparent Electronic Materials
McCoul, D., Hu, W., Gao, M., Mehta, V., & Pei, Q. (2016) · Advanced Electronic Materials · doi:10.1002/aelm.201500407 · Cited by 293
Mazutis, L., Araghi, A. F., Miller, O. J., Baret, J.-C., Frenz, L., Janoshazi, A., Taly, V., Miller, B. J., Hutchison, J. B., Link, D., et al. (2009) · Analytical Chemistry · doi:10.1021/ac900403z · Cited by 263
Vacuum filling of complex microchannels with liquid metal
Lin, Y., Gordon, O., Khan, M. R., Vasquez, N., Genzer, J., & Dickey, M. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00426e · Cited by 257
Gérard, A., Woolfe, A., Mottet, G., Reichen, M., Castrillon, C., Menrath, V., Ellouze, S., Poitou, A., Doineau, R., Briseno-Roa, L., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0466-7 · Cited by 256
A Path Beyond Metal and Silicon:Polymer/Nanomaterial Composites for Stretchable Strain Sensors
Qiu, A., Li, P., Yang, Z., Yao, Y., Lee, I., & Ma, J. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201806306 · Cited by 237
Material approaches to stretchable strain sensors
Park, J., You, I., Shin, S., & Jeong, U. (2015) · ChemPhysChem · doi:10.1002/cphc.201402810 · Cited by 216
Metadata
- Authors
- Siegel, A. C., Bruzewicz, D. A., Weibel, D. B., & Whitesides, G. M.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2007-02-07
- Volume
- 19
- Issue
- 5
- Pages
- 727-733
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2035396646
- Cited by
- 212
- References
- 1
- FWCI
- 13.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.