Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 426

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Self‐Powered High‐Resolution and Pressure‐Sensitive Triboelectric Sensor Matrix for Real‐Time Tactile Mapping

Wang, Xiandi, Zhang, Hanlu, Dong, Lin, Han, Xun, Du, Weiming, Zhai, Junyi, Pan, Caofeng, Wang, Zhong Lin·2016·Advanced Materials

Abstract

A triboelectric sensor matrix (TESM) can accurately track and map 2D tactile sensing. A self-powered, high-resolution, pressure-sensitive, flexible and durable TESM with 16 × 16 pixels is fabricated for the fast detection of single-point and multi-point touching. Using cross-locating technology, a cross-type TESM with 32 × 20 pixels is developed for more rapid tactile mapping, which significantly reduces the addressing lines from m × n to m + n.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201503407

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

See all 426

Metadata

Authors
Wang, X., Zhang, H., Dong, L., Han, X., Du, W., Zhai, J., Pan, C., & Wang, Z. L.
Venue
Advanced Materials
Publisher
Wiley
Published
2016-02-16
Volume
28
Issue
15
Pages
2896-2903
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2274856332
Cited by
426
References
42
FWCI
21.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self‐Powered High‐Resolution and Pressure‐Sensitive Triboelectric Sensor Matrix for Real‐Time Tactile Mapping. https://app.cochat.ai/papers/10.1002/adma.201503407
The paper
Wang, X., Zhang, H., Dong, L., Han, X., Du, W., Zhai, J., Pan, C., & Wang, Z. L. (2016). Self‐Powered High‐Resolution and Pressure‐Sensitive Triboelectric Sensor Matrix for Real‐Time Tactile Mapping. Advanced Materials. https://doi.org/10.1002/adma.201503407

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.