An Epidermal Stimulation and Sensing Platform for Sensorimotor Prosthetic Control, Management of Lower Back Exertion, and Electrical Muscle Activation
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
The design of an ultrathin, conformal electronic device that integrates electrotactile stimulation with electromyography, temperature, and strain sensing in a single, simple platform is reported. Experiments demonstrate simultaneous use of multiple modes of operation of this type of device in the sensorimotor control of robotic systems, in the monitoring of lower back exertion and in muscle stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“In this high frequency vibration stimulation, piezoelectric stimulators based on the inverse piezoelectric effect are also a good alternative.[595–597]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [596]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationA stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Self-citationMultifunctional wearable devices for diagnosis and therapy of movement disorders
Son, D., Lee, J., Qiao, S., Ghaffari, R., Kim, J., Lee, J. E., Song, C., Kim, S. J., Lee, D. J., Jun, S. W., et al. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.38 · Cited by 1,462
Self-citationTee, B. C.-K., Wang, C., Allen, R., & Bao, Z. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.192 · Cited by 1,419
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Self-citationSoft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
Self-citation
Research works printed but not linked: 2
- Gerasimenko Y., 1989, Ann. Phys. Rehabil. Med., 52, 53
- Akhtar A., 2014, Haptics Symp. (HAPTICS), 69
Cited by
Items 301–306 of 306
Recent Progress in Skin Bioelectronics for Electrophysiological Monitoring
Hu, G., Shi, X., & Yang, A. (2026) · Advanced Materials Technologies · doi:10.1002/admt.71372
Electrotactile interface enabled by EMG-based perception decoding for information delivery
Guo, J., Du, Y., Ning, H., 张忠强, Wang, Z. L., & Wei, D. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.182738
Huang, C.-C., Lin, Y.-H., Liu, C., Lin, H.-F., & Liao, Y. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118649
Muscle Activity Monitoring for Disease Analysis and Development of Prosthetic Device
Koithyar, A., Shwetha, A. N., Chandrashekar, D., Basava, K. L. D., Rakshith, R., & Ganesh, L. S. (2026) · Lecture notes in electrical engineering · doi:10.1007/978-981-95-7813-9_9
Iranshahi, A., Mehranpour, M., & Ahmadi, S. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118663
Types of wearable sensors based on detection strategies
Singh, D., Thapa, S., Verma, R., & Singh, J. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36504-1.10002-7
Metadata
- Authors
- Xu, B., Akhtar, A., Liu, Y., Chen, H., Yeo, W., Park, S. I., Boyce, B., Kim, H., Yu, J., Lai, H., Jung, S., Zhou, Y., Kim, J., Cho, S., Huang, Y., Bretl, T., & Rogers, J. A.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Northwestern University (US)
- Department of Materials Science and Engineering Beckman Institute, and Frederick Seitz Materials Research Laboratory University of Illinois at Urbana‐Champaign Urbana IL 61801 USA
- Corresponding author
- Rogers, John A.
- ORCID
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2015-10-15
- Volume
- 28
- Issue
- 22
- Pages
- 4462-4471
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- PMC
- PMC4833675
- OpenAlex
- W1901658528
- Semantic Scholar
- 6bdf693afecad1e8ff8b7d2aea3ab5248406bb6e
- Cited by
- 304
- References
- 46
- Citations by year
- 2026: 16 · 2025: 21 · 2024: 26 · 2023: 36 · 2022: 37 · 2021: 34 · 2020: 40 · 2019: 32 · 2018: 28 · 2017: 22 · 2016: 11 · 2015: 1
- FWCI
- 10.28
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Advanced Materials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (F30HD084201)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- epidermal electronics, electrocutaneous stimulation, electromyography, temperature sensing, strain sensing, robot control, neuromuscular electrical stimulation, wearable sensors
- MeSH terms
- Electromyography, Epidermis, Physical Exertion, Humans, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.