The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Multiscale Humidity Visualization by Environmentally Sensitive Fluorescent Molecular Rotors
Abstract
Building humidity sensors possessing the features of diverse‐configuration compatibility, and capability of measurement of spatial and temporal humidity gradients is of great interest for highly integrated electronics and wearable monitoring systems. Herein, a visual sensing approach based on fluorescent imaging is presented, by assembling aggregation‐induced‐emission (AIE)‐active molecular rotors into a moisture‐captured network; the resulting AIE humidity sensors are compatible with diverse applications, having tunable geometries and desirable architectures. The invisible information of relative humidity (RH) is transformed into different fluorescence colors that enable direct observation by the naked eyes based on the twisted intramolecular charge‐transfer effect of the AIE‐active molecular rotors. The resulting AIE humidity sensors show excellent performance in terms of good sensitivity, precise quantitative measurement, high spatial–temporal resolution, and fast response/recovery time. Their multiscale applications, such as regional environmental RH detection, internal humidity mapping, and sensitive human‐body humidity sensing are demonstrated. The proposed humidity visualization strategy may provide a new insight to develop humidity sensors for various applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Self-citationAn ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Relative Humidity Sensors Based on an Environment-Sensitive Fluorophore in Hydrogel Films
Tellis, J. C., Strulson, C. A., Myers, M. M., & Kneas, K. A. (2011) · Analytical Chemistry · doi:10.1021/ac102616w · Cited by 75
Cited by
Duan, Z., Jiang, Y., Yan, M., Wang, S., Yuan, Z., Zhao, Q., Sun, P., Xie, G., Du, X., & Tai, H. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b05709 · Cited by 485
Precise Molecular Design for High‐Performance Luminogens with Aggregation‐Induced Emission
Xu, S., Duan, Y., & Liu, B. (2020) · Advanced Materials · doi:10.1002/adma.201903530 · Cited by 476
Song, F., Xu, Z., Zhang, Q., Zhao, Z., Zhang, H., Zhao, W., Qiu, Z., Qi, C., Zhang, H., Sung, H. H. Y., et al. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201800051 · Cited by 432
Self-citationQi, J., Sun, C., Zebibula, A., Zhang, H., Kwok, R. T. K., Zhao, X., Xi, W., Lam, J. W. Y., Qian, J., & Tang, B. Z. (2018) · Advanced Materials · doi:10.1002/adma.201706856 · Cited by 418
Self-citationProgress and challenges in fabrication of wearable sensors for health monitoring
Nasiri, S., & Khosravani, M. R. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112105 · Cited by 295
Metadata
- Authors
- Cheng, Y., Wang, J., Qiu, Z., Zheng, X., Leung, N. L. C., Lam, J. W. Y., & Tang, B. Z.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2017-10-16
- Volume
- 29
- Issue
- 46
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2766258309
- Cited by
- 247
- References
- 3
- FWCI
- 9.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiscale Humidity Visualization by Environmentally Sensitive Fluorescent Molecular Rotors. https://app.cochat.ai/papers/10.1002/adma.201703900
- The paper
- Cheng, Y., Wang, J., Qiu, Z., Zheng, X., Leung, N. L. C., Lam, J. W. Y., & Tang, B. Z. (2017). Multiscale Humidity Visualization by Environmentally Sensitive Fluorescent Molecular Rotors. Advanced Materials. https://doi.org/10.1002/adma.201703900
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.