The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Activatable Semiconducting Theranostics: Simultaneous Generation and Ratiometric Photoacoustic Imaging of Reactive Oxygen Species In Vivo
Abstract
Enhancing the generation of reactive oxygen species (ROS) is an effective anticancer strategy. However, it is a great challenge to control the production and to image ROS in vivo, both of which are vital for improving the efficacy and accuracy of cancer therapy. Herein, an activatable semiconducting theranostic nanoparticle (NP) platform is developed that can simultaneously enhance ROS generation while self‐monitoring its levels through ratiometric photoacoustic (PA) imaging. The NP platform can further guide in vivo therapeutic effect in tumors. The theranostic NP platform is composed of: (i) cisplatin prodrug and ferric ion catalyst for ROS generation, a part of combination cancer therapy; and (ii) a ratiometric PA imaging nanoprobe consisting of inert semiconducting perylene‐diimide (PDI) and ROS activatable near‐infrared dye (IR790s), used in ratiometric PA imaging of ROS during cancer treatment. Ratiometric PA signals are measured at two near‐infrared excitation wavelengths: 680 and 790 nm for PDI and IR790s, respectively. The measurements show highly accurate visualization of •OH generation in vivo. This novel ROS responsive organic theranostic NP allows not only synergistic cancer chemotherapy but also real‐time monitoring of the therapeutic effect through ratiometric PA imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toxicity of iron and hydrogen peroxide: the Fenton reaction
Winterbourn, C. C. (1995) · Toxicology Letters · doi:10.1016/0378-4274(95)03532-x · Cited by 1,415
Hydrogen peroxide in the human body
Halliwell, B., Clement, M. V., & Long, L. H. (2000) · FEBS Letters · doi:10.1016/s0014-5793(00)02197-9 · Cited by 1,075
Cited by
Biomedicine Meets Fenton Chemistry
Tang, Z., Zhao, P., Wang, H., Liu, Y., & Bu, W. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00977 · Cited by 745
Wang, Q., Dai, Y., Xu, J., Cai, J., Niu, X., Zhang, L., Chen, R., Shen, Q., Huang, W., & Fan, Q. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201901480 · Cited by 369
Self-citationWan, Q., Zhang, R., Zhuang, Z., Li, Y., Huang, Y., Wang, Z., Zhang, W., Hou, J., & Tang, B. Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202002057 · Cited by 363
Self-citationChoi, K. Y., Han, H. S., Lee, E. S., Shin, J. M., Almquist, B. D., Lee, D. S., & Park, J. H. (2019) · Advanced Materials · doi:10.1002/adma.201803549 · Cited by 319
Janus Nanoparticles: From Fabrication to (Bio)Applications
Zhang, X., Fu, Q., Duan, H., Song, J., & Yang, H. (2021) · ACS Nano · doi:10.1021/acsnano.1c01146 · Cited by 286
Self-citation
Metadata
- Authors
- Yang, Z., Dai, Y., Yin, C., Fan, Q., Zhang, W., Song, J., Yu, G., Tang, W., Fan, W., Yung, B. C., Li, J., Li, X., Li, X., Tang, Y., Huang, W., Song, J., & Chen, X.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2018-04-30
- Volume
- 30
- Issue
- 23
- Pages
- e1707509-e1707509
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2802933687
- Cited by
- 208
- References
- 2
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Activatable Semiconducting Theranostics: Simultaneous Generation and Ratiometric Photoacoustic Imaging of Reactive Oxygen Species In Vivo. https://app.cochat.ai/papers/10.1002/adma.201707509
- The paper
- Yang, Z., Dai, Y., Yin, C., Fan, Q., Zhang, W., Song, J., Yu, G., Tang, W., Fan, W., Yung, B. C., Li, J., Li, X., Li, X., Tang, Y., Huang, W., Song, J., & Chen, X. (2018). Activatable Semiconducting Theranostics: Simultaneous Generation and Ratiometric Photoacoustic Imaging of Reactive Oxygen Species In Vivo. Advanced Materials. https://doi.org/10.1002/adma.201707509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.