Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 431

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

A Real‐Time Wearable UV‐Radiation Monitor based on a High‐Performance p‐CuZnS/n‐TiO2 Photodetector

Xu, Xiaojie, Chen, Jiaxin, Cai, Sa, Long, Zhenghao, Zhang, Yong, Su, Longxing, He, Sisi, Tang, Chengqiang, Liu, Peng, Peng, Huisheng, Fang, Xiaosheng·2018·Advanced Materials

Abstract

Solar radiation, especially ultraviolet (UV) light, is a major hazard for most skin‐related cancers. The growing needs for wearable health monitoring systems call for a high‐performance real‐time UV sensor to prevent skin diseases caused by excess UV exposure. To this end, here a novel self‐powered p‐CuZnS/n‐TiO 2 UV photodetector (PD) with high performance is successfully developed (responsivity of 2.54 mA W−1 at 0 V toward 300 nm). Moreover, by effectively replacing the Ti foil with a thin Ti wire for the anodization process, the conventional planar rigid device is artfully turned into a fiber‐shaped flexible and wearable one. The fiber‐shaped device shows an outstanding responsivity of 640 A W−1, external quantum efficiency of 2.3 × 10 5%, and photocurrent of ≈4 mA at 3 V, exceeding those of most current UV PDs. Its ultrahigh photocurrent enables it to be easily integrated with commercial electronics to function as a real‐time monitor system. Thus, the first real‐time wearable UV radiation sensor that reads out ambient UV power density and transmits data to smart phones via wifi is demonstrated. This work not only presents a promising wearable health monitor, but also provides a general strategy for designing and fabricating smart wearable electronic devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201803165

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 431

Metadata

Authors
Xu, X., Chen, J., Cai, S., Long, Z., Zhang, Y., Su, L., He, S., Tang, C., Liu, P., Peng, H., & Fang, X.
Venue
Advanced Materials
Publisher
Wiley
Published
2018-08-30
Volume
30
Issue
43
Pages
e1803165-e1803165
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2888886192
Cited by
431
References
33
FWCI
11.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Real‐Time Wearable UV‐Radiation Monitor based on a High‐Performance p‐CuZnS/n‐TiO2 Photodetector. https://app.cochat.ai/papers/10.1002/adma.201803165
The paper
Xu, X., Chen, J., Cai, S., Long, Z., Zhang, Y., Su, L., He, S., Tang, C., Liu, P., Peng, H., & Fang, X. (2018). A Real‐Time Wearable UV‐Radiation Monitor based on a High‐Performance p‐CuZnS/n‐TiO2 Photodetector. Advanced Materials. https://doi.org/10.1002/adma.201803165

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.