CoChat

Soft, Implantable Bioelectronic Interfaces for Translational Research

Open access
Schiavone, Giuseppe, Fallegger, Florian, Kang, Xiaoyang, Barra, Beatrice, Vachicouras, Nicolas, Roussinova, Evgenia, Furfaro, Ivan, Jiguet, Sébastien, Seáñez, Ismael, Borgognon, Simon, Rowald, Andreas, Li, Qin, Qin, Chuan, Bézard, Erwan, Bloch, Jocelyne, Courtine, Grégoire, Capogrosso, Marco, Lacour, Stéphanie P. · 2020 · Advanced Materials
Cited by 116

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

The convergence of materials science, electronics, and biology, namely bioelectronic interfaces, leads novel and precise communication with biological tissue, particularly with the nervous system. However, the translation of lab‐based innovation toward clinical use calls for further advances in materials, manufacturing and characterization paradigms, and design rules. Herein, a translational framework engineered to accelerate the deployment of microfabricated interfaces for translational research is proposed and applied to the soft neurotechnology called electronic dura mater, e‐dura. Anatomy, implant function, and surgical procedure guide the system design. A high‐yield, silicone‐on‐silicon wafer process is developed to ensure reproducible characteristics of the electrodes. A biomimetic multimodal platform that replicates surgical insertion in an anatomy‐based model applies physiological movement, emulates therapeutic use of the electrodes, and enables advanced validation and rapid optimization in vitro of the implants. Functionality of scaled e‐dura is confirmed in nonhuman primates, where epidural neuromodulation of the spinal cord activates selective groups of muscles in the upper limbs with unmet precision. Performance stability is controlled over 6 weeks in vivo. The synergistic steps of design, fabrication, and biomimetic in vitro validation and in vivo evaluation in translational animal models are of general applicability and answer needs in multiple bioelectronic designs and medical technologies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.201906512

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Schiavone, G., Fallegger, F., Kang, X., Barra, B., Vachicouras, N., Roussinova, E., Furfaro, I., Jiguet, S., Seáñez, I., Borgognon, S., Rowald, A., Li, Q., Qin, C., Bézard, E., Bloch, J., Courtine, G., Capogrosso, M., & Lacour, S. P.
Venue
Advanced Materials
Publisher
Wiley
Published
2020-03-16
Volume
32
Issue
17
Pages
e1906512-e1906512
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W3011098270
Cited by
116
References
9
FWCI
6.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.