The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Sensing of COVID‐19 Antibodies in Seconds via Aerosol Jet Nanoprinted Reduced‐Graphene‐Oxide‐Coated 3D Electrodes
Open accessAbstract
Rapid diagnosis is critical for the treatment and prevention of diseases. An advanced nanomaterial‐based biosensing platform that detects COVID‐19 antibodies within seconds is reported. The biosensing platform is created by 3D nanoprinting of three‐dimensional electrodes, coating the electrodes by nanoflakes of reduced‐graphene‐oxide (rGO), and immobilizing specific viral antigens on the rGO nanoflakes. The electrode is then integrated with a microfluidic device and used in a standard electrochemical cell. When antibodies are introduced on the electrode surface, they selectively bind with the antigens, changing the impedance of the electrical circuit which is detected via impedance spectroscopy. Antibodies to SARS‐CoV‐2 spike S1 protein and its receptor‐binding‐domain (RBD) are detected at a limit‐of‐detection of 2.8 × 10 −15 and 16.9 × 10 −15 m , respectively, and read by a smartphone‐based user interface. The sensor can be regenerated within a minute by introducing a low‐pH chemistry that elutes the antibodies from the antigens, allowing successive sensing of test samples using the same sensor. Sensing of S1 and RBD antibodies is specific, which cross‐reacts neither with other antibodies such as RBD, S1, and nucleocapsid antibody nor with proteins such as interleukin‐6. The proposed sensing platform could also be useful to detect biomarkers for other infectious agents such as Ebola, HIV, and Zika.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A novel coronavirus from patients with pneumonia in China, 2019
Zhu, N., Zhang, D., Wang, W., Li, X., Yang, B., Song, J., Zhao, X., Huang, B., Shi, W., Lu, R., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2001017 · Cited by 28,244
A pneumonia outbreak associated with a new coronavirus of probable bat origin
Zhou, P., Yang, X.-L., Wang, X.-G., Hu, B., Zhang, L., Zhang, W., Si, H.-R., Zhu, Y., Li, B., Huang, C.-L., et al. (2020) · Nature · doi:10.1038/s41586-020-2012-7 · Cited by 21,969
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR
Corman, V. M., Landt, O., Kaiser, M., Molenkamp, R., Meijer, A., Chu, D. K., Bleicker, T., Brünink, S., Schneider, J., Schmidt, M. L., et al. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.3.2000045 · Cited by 7,344
A practical beginner’s guide to cyclic voltammetry
Elgrishi, N., Rountree, K. J., McCarthy, B. D., Rountree, E. S., Eisenhart, T. T., & Dempsey, J. L. (2018) · Journal of Chemical Education · doi:10.1021/acs.jchemed.7b00361 · Cited by 4,263
Hui, D. S., I Azhar, E., Madani, T. A., Ntoumi, F., Kock, R., Dar, O., Ippolito, G., Mchugh, T. D., Memish, Z. A., Drosten, C., et al. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.01.009 · Cited by 3,809
Cell entry mechanisms of SARS-CoV-2
Shang, J., Wan, Y., Luo, C., Ye, G., Geng, Q., Auerbach, A., & Li, F. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2003138117 · Cited by 3,142
Antibody responses to SARS-CoV-2 in patients with COVID-19
Long, Q.-X., Liu, B.-Z., Deng, H.-J., Wu, G.-C., Deng, K., Chen, Y.-K., Liao, P., Qiu, J.-F., Lin, Y., Cai, X.-F., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0897-1 · Cited by 2,876
CRISPR–Cas12-based detection of SARS-CoV-2
Broughton, J. P., Deng, X., Yu, G., Fasching, C. L., Servellita, V., Singh, J., Miao, X., Streithorst, J. A., Granados, A., Sotomayor-Gonzalez, A., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0513-4 · Cited by 2,717
Additively manufactured hierarchical stainless steels with high strength and ductility
Wang, Y. M., Voisin, T., McKeown, J. T., Ye, J., Calta, N. P., Li, Z., Zeng, Z., Zhang, Y., Chen, W., Roehling, T. T., et al. (2018) · Nature Materials · doi:10.1038/nmat5021 · Cited by 2,613
Quantifying SARS-CoV-2 transmission suggests epidemic control with digital contact tracing
Ferretti, L., Wymant, C., Kendall, M., Zhao, L., Nurtay, A., Abeler-Dörner, L., Parker, M., Bonsall, D., & Fraser, C. (2020) · Science · doi:10.1126/science.abb6936 · Cited by 2,512
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Park, H., Harris, S. M., Boldenow, E., Aronoff, D. M., Rea, M., Xi, C., & Loch‐Caruso, R. (2024) · American Journal of Reproductive Immunology · doi:10.1111/aji.13807 · Cited by 2,087
Li, Z., Yi, Y., Luo, X., Xiong, N., Liu, Y., Li, S., Sun, R., Wang, Y., Hu, B., Chen, W., et al. (2020) · Journal of Medical Virology · doi:10.1002/jmv.25727 · Cited by 1,771
Human neutralizing antibodies elicited by SARS-CoV-2 infection
Ju, B., Zhang, Q., Ge, J., Wang, R., Sun, J., Ge, X., Yu, J., Shan, S., Zhou, B., Song, S., et al. (2020) · Nature · doi:10.1038/s41586-020-2380-z · Cited by 1,667
Profiling Early Humoral Response to Diagnose Novel Coronavirus Disease (COVID-19)
Guo, L., Ren, L., Yang, S., Xiao, M., Chang, D., Yang, F., Dela Cruz, C. S., Wang, Y., Wu, C., Xiao, Y., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa310 · Cited by 1,587
COVID-19: towards controlling of a pandemic
Bedford, J., Enria, D., Giesecke, J., Heymann, D. L., Ihekweazu, C., Kobinger, G., Lane, H. C., Memish, Z., Oh, M.-D., Sall, A. A., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30673-5 · Cited by 1,545
Determination of the Local Chemical Structure of Graphene Oxide and Reduced Graphene Oxide
Erickson, K., Erni, R., Lee, Z., Alem, N., Gannett, W., & Zettl, A. (2010) · Advanced Materials · doi:10.1002/adma.201000732 · Cited by 1,485
Baum, A., Fulton, B. O., Wloga, E., Copin, R., Pascal, K. E., Russo, V., Giordano, S., Lanza, K., Negron, N., Ni, M., et al. (2020) · Science · doi:10.1126/science.abd0831 · Cited by 1,253
Tan, C. W., Chia, W. N., Qin, X., Liu, P., Chen, M. I.-C., Tiu, C., Hu, Z., Chen, V. C.-W., Young, B. E., Sia, W. R., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0631-z · Cited by 1,202
Spread and dynamics of the COVID-19 epidemic in Italy: Effects of emergency containment measures
Gatto, M., Bertuzzo, E., Mari, L., Miccoli, S., Carraro, L., Casagrandi, R., & Rinaldo, A. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2004978117 · Cited by 1,051
COVID-19 pandemic: perspectives on an unfolding crisis
Spinelli, A., & Pellino, G. (2020) · British Journal of Surgery · doi:10.1002/bjs.11627 · Cited by 855
A graphene-based electrochemical sensor for sensitive detection of paracetamol
Kang, X., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Talanta · doi:10.1016/j.talanta.2010.01.009 · Cited by 613
Structural basis of a shared antibody response to SARS-CoV-2
Yuan, M., Liu, H., Wu, N. C., Lee, C.-C. D., Zhu, X., Zhao, F., Huang, D., Yu, W., Hua, Y., Tien, H., et al. (2020) · Science · doi:10.1126/science.abd2321 · Cited by 589
Recent advances and perspectives of nucleic acid detection for coronavirus
Shen, M., Zhou, Y., Ye, J., Abdullah AL-maskri, A. A., Kang, Y., Zeng, S., & Cai, S. (2020) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2020.02.010 · Cited by 520
Sabaté del Río, J., Henry, O. Y. F., Jolly, P., & Ingber, D. E. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0566-z · Cited by 450
Serological immunochromatographic approach in diagnosis with SARS-CoV-2 infected COVID-19 patients
Pan, Y., Li, X., Yang, G., Fan, J., Tang, Y., Zhao, J., Long, X., Guo, S., Zhao, Z., Liu, Y., et al. (2020) · Journal of Infection · doi:10.1016/j.jinf.2020.03.051 · Cited by 366
Developing antibody tests for SARS-CoV-2
Petherick, A. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30788-1 · Cited by 359
Wu, N., She, X., Yang, D., Wu, X., Su, F., & Chen, Y. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm33114d · Cited by 232
Bwire, G. M., Majigo, M. V., Njiro, B. J., & Mawazo, A. (2021) · Journal of Medical Virology · doi:10.1002/jmv.26349 · Cited by 230
Saleh, M. S., Hu, C., & Panat, R. (2017) · Science Advances · doi:10.1126/sciadv.1601986 · Cited by 203
Self-citationOn the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors
Lavín, Á., de Vicente, J., Holgado, M., et al. (2018) · Sensors · doi:10.3390/s18072038 · Cited by 150
den Hartog, G., Schepp, R. M., Kuijer, M., GeurtsvanKessel, C., van Beek, J., Rots, N., Koopmans, M. P. G., van der Klis, F. R. M., & van Binnendijk, R. S. (2020) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiaa479 · Cited by 137
Facile biosensors for rapid detection of COVID-19
Xu, L., Li, D., Ramadan, S., Li, Y., & Klein, N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112673 · Cited by 135
Ali, M. A., Wang, X., Chen, Y., Jiao, Y., Mahal, N. K., Satyanarayana, M., Castellano, M. J., Schnable, J. C., Schnable, P. S., & Dong, L. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b07120 · Cited by 131
Self-citationParticulate Alum via Pickering Emulsion for an Enhanced COVID‐19 Vaccine Adjuvant
Peng, S., Cao, F., Xia, Y., Gao, X., Dai, L., Yan, J., & Ma, G. (2020) · Advanced Materials · doi:10.1002/adma.202004210 · Cited by 128
An Antioxidant Enzyme Therapeutic for COVID‐19
Qin, M., Cao, Z., Wen, J., Yu, Q., Liu, C., Wang, F., Zhang, J., Yang, F., Li, Y., Fishbein, G. A., et al. (2020) · Advanced Materials · doi:10.1002/adma.202004901 · Cited by 125
Fundamentals of bioMEMS and medical microdevices
(2006) · Choice Reviews Online · doi:10.5860/choice.43-6554 · Cited by 95
3-D printed adjustable microelectrode arrays for electrochemical sensing and biosensing
Yang, H., Rahman, M. T., Du, D., Panat, R. P., & Lin, Y. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.02.113 · Cited by 94
Self-citationRiccò, M., Ferraro, P., Gualerzi, G., Ranzieri, S., Henry, B. M., Said, Y. B., Pyatigorskaya, N. V., Nevolina, E., Wu, J., Bragazzi, N. L., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9051515 · Cited by 86
Kandimalla, V. B., Neeta, N. S., Karanth, N. G., Thakur, M. S., Roshini, K. R., Rani, B., Pasha, A., & Karanth, N. G. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.03.027 · Cited by 76
Liu, E. Y., Jung, S., Weitz, D. A., Yi, H., & Choi, C. (2017) · Lab on a Chip · doi:10.1039/c7lc01088e · Cited by 63
Chia, J. S. Y., Tan, M. T. T., Khiew, P. S., et al. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.01.023 · Cited by 48
Li, Q., Gordon, M. N., Cao, C., Ugen, K. E., & Morgan, D. (2007) · BMC Neuroscience · doi:10.1186/1471-2202-8-22 · Cited by 48
Cited by
Laschuk, N. O., Easton, E. B., & Zenkina, O. V. (2021) · RSC Advances · doi:10.1039/d1ra03785d · Cited by 843
2D Materials in Flexible Electronics: Recent Advances and Future Prospectives
Katiyar, A. K., Hoang, A. T., Xu, D., Hong, J., Kim, B. J., Ji, S., & Ahn, J.-H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00302 · Cited by 363
Flexible Plasmonic Biosensors for Healthcare Monitoring: Progress and Prospects
Song, L., Chen, J., Xu, B. B., & Huang, Y. (2021) · ACS Nano · doi:10.1021/acsnano.1c07176 · Cited by 186
Metadata
- Authors
- Ali, M. A., Hu, C., Jahan, S., Yuan, B., Saleh, M. S., Ju, E., Gao, S., & Panat, R.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2020-12-22
- Volume
- 33
- Issue
- 7
- Pages
- e2006647-e2006647
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3116273806
- Cited by
- 343
- References
- 44
- FWCI
- 20.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.